DOI QR코드

DOI QR Code

Development of a Four-way Interface for Online Capillary Isoelectric Focusing-Electrospray-Mass Spectrometry (CIEF-ESI-MS)

  • Yu, Hai Dong (Division of Metrology for Quality of Life, Korea Research Institute of Standards and Science) ;
  • Kim, Byungjoo (Division of Metrology for Quality of Life, Korea Research Institute of Standards and Science) ;
  • Shin, Dae-Ho (Bio Medical Technologies Ltd.) ;
  • Ahn, Seonghee (Division of Metrology for Quality of Life, Korea Research Institute of Standards and Science)
  • Received : 2013.12.11
  • Accepted : 2013.12.19
  • Published : 2013.12.30

Abstract

A new interface for coupling CIEF and MS using a four-way cross has been developed in a single mechanical system. This new interface could be operated without the electric discontinuity and reinstallation of lines. Additionally, a bare fused silica capillary was facilitated as a spray needle to produce electrospray and to guide catholyte or sheath liquid. Focusing for CIEF was completed in a hanging droplet at the end of spray needle. This capillary spray needle also provided stable spray, enhanced the ionization efficiency and increased sensitivity. Results with carbonic anhydrase I showed that focusing and spraying were well completed with the new interface and the new spray needle.

Keywords

References

  1. Righetti, P. G. Isoelectric Focusing: Theory, Methodology and Applications; Elsevier Biomedical Press: Amsterdam, 1983.
  2. Hjerten, S.; Zhu, M. D. Journal of Chromatogr. 1985, 346, 265. https://doi.org/10.1016/S0021-9673(00)90512-0
  3. Tang, Q.; Harrata, A. K.; Lee, C. S. Anal. Chem. 1995, 67, 3515. https://doi.org/10.1021/ac00115a021
  4. Tang, Q.; Harrata, A. K.; Lee, C. S. Anal. Chem. 1997, 69, 3177. https://doi.org/10.1021/ac970015o
  5. Martinovic, S.; Berger, S. J.; Pasa-Polic, L.; Smith, R. D. Anal. Chem. 2000, 72, 5356. https://doi.org/10.1021/ac0004557
  6. Clarke, N. J.; Naylor, S. Biomed. Chromatogr. 2002, 16, 287. https://doi.org/10.1002/bmc.159
  7. Kuroda, Y.; Yukinaga, H.; Kitano, M.; Noguchi, T.; Nemati, M.; Shibukawa, A.; Nakagawa, T.; Matsuzaki, K. J. Pharm. Biomed. Anal. 2005, 37, 423. https://doi.org/10.1016/j.jpba.2004.11.025
  8. Mokaddem, M.; Gareil, P.; Varenne, A. Electrophoresis 2009, 30, 4040. https://doi.org/10.1002/elps.200900091
  9. Smith, R. D.; Olivares, J. A.; Nguyen, N. T.; Udseth, H. R. Anal. Chem. 1988, 60, 436. https://doi.org/10.1021/ac00156a013
  10. Pleasance, S.; Thibault, P.; Kelly, J. J. Chromatogr. 1992, 591, 325. https://doi.org/10.1016/0021-9673(92)80250-X
  11. Shen, Y.; Smith, R. D. J. Microcol. Separations 2000, 12, 135. https://doi.org/10.1002/(SICI)1520-667X(2000)12:3<135::AID-MCS2>3.0.CO;2-5