대한방사선치료학회지 (The Journal of Korean Society for Radiation Therapy)
- 제24권2호
- /
- Pages.189-196
- /
- 2012
- /
- 1598-8449(pISSN)
자체 제작한 Foxtail Millet Vacuum Cushion의 광자선 피부암 치료 시 유용성 검증
Evaluation of the Efficiency of the Foxtail Millet Vacuum Cushion in Skin Cancer Radiation Treatment
- 최신철 (이화여자대학교 목동병원 방사선종양학과) ;
- 이경재 (이화여자대학교 목동병원 방사선종양학과) ;
- 정성민 (이화여자대학교 목동병원 방사선종양학과) ;
- 오태성 (이화여자대학교 목동병원 방사선종양학과) ;
- 박종일 (이화여자대학교 목동병원 방사선종양학과) ;
- 신현교 (이화여자대학교 목동병원 방사선종양학과)
- Choi, Shin-Cheol (Department of Radiation Oncology, Ewha Womans University Mokdong Hospital) ;
- Lee, Kyung-Jae (Department of Radiation Oncology, Ewha Womans University Mokdong Hospital) ;
- Jung, Sung-Min (Department of Radiation Oncology, Ewha Womans University Mokdong Hospital) ;
- Oh, Tae-Seong (Department of Radiation Oncology, Ewha Womans University Mokdong Hospital) ;
- Park, Jong-Il (Department of Radiation Oncology, Ewha Womans University Mokdong Hospital) ;
- Shin, Hyun-Kyo (Department of Radiation Oncology, Ewha Womans University Mokdong Hospital)
- 투고 : 2012.06.19
- 심사 : 2012.08.24
- 발행 : 2012.09.30
초록
목 적: 광자선을 이용한 피부암 치료 시 피부 선량의 충족과 환자 셋업의 재현성 유지는 치료의 성과에 있어서 무엇보다 중요한 요소이다. 이에 본 연구는 기존에 시행해 오던 방식이었던 상품화된 고정기구 및 조직 등가물질의 조합에 의한 치료 방식이나 물 수조를 이용한 치료 시 발생하던 단점들을 보완하기 위해 Foxtail Millet Vacuum Cushion (FMVC)의 자체 제작을 실시하고 그 유용성을 검증하여 광자선 피부암 치료의 질을 높이고자 한다. 대상 및 방법: 자체 제작한 FMVC의 광자선 투과도에 따른 절대 선량 및 선량 분포를 분석하기 위해 조직과 밀도가 유사한 고체 팬톰과 볼루스에 대해 비교 측정하였다. 조사야
Purpose: The sufficiency of skin dose and the reemergence of patient set-up position to the success of skin cancer radiation treatment is a very important element. But the conventional methods to increase the skin dose were used to vacuum cushion, bolus and water tank have several weak points. For this reason, we producted Foxtail Millet Vacuum Cushion and evaluated the efficiency of the Foxtail Millet Vacuum Cushion in skin cancer Radiation treatment. Materials and Methods: We measured absolute dose for 3 materials (Foxtail Millet Vacuum Cushion, bolus and solid water phantom) and compared each dose distribution. We irradiated 6 MV 100 MU photon radiation to every material of 1 cm, 2 cm, 3 cm thickness at three times. We measured absolute dose and compared dose distribution. Finally we inspected the CT simulation and radiation therapy planing using the Foxtail Millet Vacuum Cushion. Results: Absolute dose of Foxtail Millet Vacuum Cushion was similar to absolute dose of bolus and solid water phantom's result in each thickness. it Showed only the difference of 0.1~0.2% between each material. Also the same result in dose distribution comparison. About 97% of the dose distribution was within the margin of error in the prescribed ranges (