DOI QR코드

DOI QR Code

A Study on Performance Improvement of a Heat Pump Dryer with an Extra Evaporator Outside

보조 외부 증발기를 이용한 히트펌프 건조기 성능 향상에 관한 연구

  • Lee, Young-Lim (Department of Mechanical and Automative Engineering, Kongju National University) ;
  • Park, Sang-Jun (Department of Mechanical Engineering, Graduate School, Kongju National University) ;
  • Hwang, Il-Sun (Department of Mechanical Engineering, Graduate School, Kongju National University)
  • 이영림 (공주대학교 기계자동차공학부) ;
  • 박상준 (공주대학교 대학원 기계공학과) ;
  • 황일선 (공주대학교 대학원 기계공학과)
  • Received : 2012.05.11
  • Published : 2012.10.10

Abstract

A heat pump dryer for the frozen food needs to preheat the air to a certain temperature where condensation can efficiently occur. In this study, an analysis of a heat pump dryer performance with operating conditions, an analysis of supplying heat with internal and external evaporators and a warm-up experiment with the evaporators have been performed. The results showed that the external evaporator can significantly accelerate the warm-up time of the dryer, so that it can reduce power consumption greatly. The use of the external evaporator is more efficient for higher ambient temperature. In addition, it was found that COP decreases and the range of evaporating pressure for the evaporator becomes narrower as the condensing temperature of the condenser increases.

Keywords

References

  1. Mujumdar, A. S., 1995, Handbook of Industrial Drying, Marcel Dekker, Inc., New York.
  2. Bannister, P., Carrington, G., and Chen, G., 2002, Heat Pump Dehumidifier Drying Technology Status, Potential and Prospects, Proc. of 7th IEA Heat Pump Conference, Vol. 1, pp. 219- 230
  3. Bannister, P., Chen. G., Grey, A., Carrington, C. G., and Sun, Z. F., 1997, Economic Reduction of Greenhouse Gas Emission Through Enhanced Dehumidifier Timber Drying, Proc. of 19th Int. Congress of Refrigeration, pp. 241- 249.
  4. Wijesighe, B., 1997, Low Temperature Drying of Food Materials Using Energy-Efficient Heat Pump Dryers, CADDET Newsletter, No. 7, pp. 4-5.
  5. Cho, H. H., Baek, C. H., Ryu, C. G., and Kim, Y. C., 2007, Simulation Study on the Performance Characteristics of a $CO_{2}$ Cooling System with an Expander, Korean Journal of Airconditioning and refrigeration Engineering, pp. 630-639.
  6. Lee, J. S., 2008, Performance Analysis of a Refrigeration System with Parallel Control of Evaporation Pressure, Transactions of the Korean Society of Mechanical Engineers, B., Vol. 32, No. 8, pp. 567-573. https://doi.org/10.3795/KSME-B.2008.32.8.567
  7. Bivens, D. B., Allgood, C. C., Shiflett, M. B., Patron, D. M., Chisolm, T. C., Shely, G. S., Yokozeki, A., Wells, W. D., and Geiger, K. A., 1994, HCFC-22 alternative for air conditioners and heat pumps, ASHRAE Transactions, Vol. 100, No. 2, pp. 566-572.
  8. Hall, C. W., 1980, Drying and Storage of Agricultural Crops, AVIP Pushlishing Co., Inc.
  9. Buelow, F. H., 1958, Drying Grain with Solar Energy, Michigan State University, Agri. Exp. Stn, Q. Bull, Vol. 41.
  10. Yoon, W. M. and Lee, J. Y., 2004, Effect of Drying method on the Quality of Red pepper, Journal of Natural Sciences, Vol. 14, No. 1, pp. 139-149.
  11. EES, 2012, F-chart Software LLC., V9.100-3D.