참고문헌
- Albright, L. D., 1990. Environment control for animals and plants. ASAE. St. Joseph, Michigan. p.31-32.
- Abdel-Ghany, A. M., and T. Kozai, 2006. Cooling efficiency of fogging systems for greenhouses. Biosystems Engineering 94(1): 97-109. https://doi.org/10.1016/j.biosystemseng.2006.02.008
- Arbel, A., O. Yekutieli, and M. Barak, 1999. Performance of a fog system for cooling greenhouses. J. Agric. Engng Res. 72: 129-136. https://doi.org/10.1006/jaer.1998.0351
- Arbel, A., M. Barak, and A. Shklyar, 2003. Combination of forced ventilation and fogging systems for cooling greenhouses. Biosystems Engineering 84(1): 45-55. https://doi.org/10.1016/S1537-5110(02)00216-7
- ASAE Standards, 1997. Heating, ventilating and cooling greenhouses. ASAE. St. Joseph, Michigan. p.663-670.
- Kim, M. K., K. S. Kim, and H. J. Kwon, 2001a. The cooling effect of fog cooling system as affected by air exchange rate in natural ventilation greenhouse. Journal of Bio-Environment Control 10(1): 10-14 (in Korean).
- Kim, M. K., K. S. Kim, and S. W. Nam, 2001b. Efficient application of greenhouse cooling systems. Ministry of Agriculture and Forestry. pp.186-188 (in Korean).
- Kittas, C., T. Bartzanas, and A. Jaffrin, 2001. Greenhouse evaporative cooling: measurement and data analysis. Transactions of the ASAE 44: 683-689.
- Kittas, C., T. Bartzanas, and A. Jaffrin, 2003. Temperature gradients in a partially shaded large greenhouse equipped with evaporative cooling pads. Biosystems Engineering 85: 87-94. https://doi.org/10.1016/S1537-5110(03)00018-7
- Lee, H. W., and Y.S. Kim, 2011. Application of low pressure fogging system for commercial tomato greenhouse cooling. Journal of Bio-Environment Control 20(1): 1-7 (in Korean).
- Li, S., and D. H. Willits, 2008. Comparing low-pressure and high-pressure fogging systems in naturally ventilated greenhouses. Biosystems Engineering 101: 69-77. https://doi.org/10.1016/j.biosystemseng.2008.06.004
- Montero, J. I., A. Anton, C. Biel, and A. Franquet, 1990. Cooling of greenhouses with compressed air fogging nozzles. Acta Horticulturae 281: 199-209.
- Nam, S. W., G. A. Giacomelli, K. S. Kim, and N. Sabeh, 2005. Analysis of temperature gradients in greenhouse equipped with fan and pad system by CFD method. Journal of Bio-Environment Control 14(2): 76-82 (in Korean).
- Nam, S. W., W. M. Seo, Y. C. Yoon, S. K. Lee, I. B. Lee, H. W. Lee, and B. K. Cho, 2008. Bio-environment control engineering. Cheongsol Pub. Daegu. p.28-68 (in Korean).
- Nam, S. W., Y. S. Kim, I. M. Sung, and G. H. Ko, 2011. Operation status and improvements of low pressure air fog nozzles installed in greenhouses. Proceeding of Bio-Environment Control 20(2): 210-211 (in Korean).
피인용 문헌
- Data-Based Model Approach to Predict Internal Air Temperature of Greenhouse vol.57, pp.3, 2015, https://doi.org/10.5389/KSAE.2015.57.3.009