Abstract
Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.
방사선 중재적 시술자들이 중재적 시술 중 잠재적인 위험을 인식하지 못하고 있다. 본 연구의 목적은 방사선 중재적 시술 중 시술자들의 피폭선량을 평가하여 이를 바탕으로 중재적 시술 중 피폭선량을 줄일 수 있는 방법의 기준안을 제안하는 것이다. 본 연구는 3개월 동안 전신선량계를 사용하여 20명의 중재적 시술자로부터 시행하는 모든 중재적 시술에서 방사선 피폭선량을 측정하였다. 방사선 중재적 시술을 시행하는 동안 납당량이 0.5 mmPb 방사선장해방어용 기구를 착용하는 것으로 평균 89.5 %의 피폭선량이 감쇄되었고, 납당량이 두꺼울수록 선량감쇄율은 증가하였다. TACE 시술을 시행하는 동안 연속투시보다 펄스투시를 선택하여 사용하는 것은 피폭선량이 평균 47.7 % 감쇄되었다. 중재적 시술자는 중재적 시술이 진행되는 동안 방사선장해방어용 기구를 착용하고, 적극적인 방사선방호 활동을 실시하여야 하며, 자신의 피폭선량에 대해 알고 있어야 한다. 그리고 피폭선량을 최소화하기 위한 자신의 위치나 장비 사용에 대해서도 알아야 한다.