DOI QR코드

DOI QR Code

An Experimental Study on Flexural/Shear Load Properties of SC(Steel Plate Concrete) Structure with Reinforced Concrete Joint

강판콘크리트 구조 이질접합부의 면외 휨/면내 전단하중 특성에 관한 실험연구

  • 이경진 (한국전력공사 전력연구원) ;
  • 황경민 (한국전력공사 전력연구원) ;
  • 함경원 (한국전력공사 전력연구원) ;
  • 김우범 (공주대학교 건축공학과)
  • Received : 2011.12.26
  • Accepted : 2012.04.10
  • Published : 2012.04.27

Abstract

This paper describes an experimental study on the mechanical characteristic and behavior of a structure that has a joint between the reinforced concrete (RC) member and steel plate concrete (SC) member. An out-of-plane flexural test on an L-type test specimen and in-plane shear test on an I-type test specimen were carried out by means of repeated cyclic loading until their failure. Based on the results, the former showed pull-out failure mode of anchored vertical bars while the latter exhibited flexural failure mode of the basement member. These results reveal that the maximum capacity of the specimens is 96% and 82%, respectively, compared with the theoretical value.

본 연구는 L형, I형 실험체에 강판 콘크리트 구조와 철근콘크리트 구조를 적용하여 이질접합부를 만들고, 실험체에 반복하중을 파괴 시 까지 가력하여 면외 휨 내력 및 면내 전단 내력을 평가하고 구조특성을 검토하기 위해서 실험연구를 수행하였다.본 연구에서 면외 휨 성능실험은 접합부에서 정착부 수직철근이 인발되면서 파괴되었고, 면내 전단성능실험은 기초부에서의 휨 균열이 발생하여 파괴되었으며, 이론식과의 비교결과 최대 내력이 실험값/이론값의 결과가 면외 휨성능실험은 96%, 면내 전단성능실험은 82%의 값을 나타내었다.

Keywords

References

  1. 김형국, 김우범, 김원기(2008) SC구조 벽-바닥 접합부의 내력 및 거동특성, 한국강구조학회 논문집, 한국강구조학회, 제 20권, 제2호, pp.347-354.
  2. 대한전기협회(2010) 전력산업기술기준(KEPIC), SN 원자력구조- SNG 강판콘크리트구조, pp.143-152.
  3. 이경진, 함경원, 박동수, 김우범(2010) 철근 콘크리트 구조와 강판 콘크리트 구조 이질접합부를 가진 보의 휨 하중 특성에 관한 실험연구, 한국강구조학회 논문집, 한국강구조학회, 제22권, 제5호, pp.455-463.
  4. 이경진, 함경원, 박동수(2009) 강판콘크리트 보의 온도하중 재하시 역학적 특성에 관한 실험적 연구, 한국강구조학회 논문집, 한국강구조학회, 제21권, 제5호, pp.443-450.
  5. 이경진, 박동수, 전재호(2006) SC구조체의 온도특성에 대한 시험연구, 대한건축학회 학술발표대회논문집, 대한건축학회, 제26권, 제1호, pp.313-316.
  6. 이승준, 김원기(2010) SC구조의 내진설계를 위한 감쇠비, 한국강구조학회 논문집, 한국강구조학회, 제22권, 제5호, pp.487-496.
  7. 古和田明(1999) 鋼板コンクリ-ト構造に關する實驗的硏究, その37 壁床接合部實驗(實驗計劃と實驗槪要), 日本建築 學會大會學術講演楩槪集.
  8. Lee K.J., Hahm, K.W., Park, D.S., and Kwon, K.J. (2008) Experimental Study on Temperature Behavior of SSC(Stiffened Steel Plate Concrete) Structures, Transactions of the Korean Nuclear Society Autumn Meeting PyeongChang, Korea, pp.767-768.

Cited by

  1. An experimental study on the flexural and shear behavior of steel plate concrete—reinforced concrete connected structures vol.257, 2013, https://doi.org/10.1016/j.nucengdes.2012.12.020
  2. Direct shear strength of rebar-coupler anchor systems for steel-plate composite (SC) walls vol.16, pp.4, 2016, https://doi.org/10.1007/s13296-016-0096-6
  3. A Study on Flexural and Shear Behavior of the Structure with Steel Plate Concrete to Reinforced Concrete Member's Connection vol.32, pp.5A, 2012, https://doi.org/10.12652/Ksce.2012.32.5A.267
  4. Structural Damping Ratio of Steel Plate Concrete(SC) Shear Wall at the Low Stress Level Identified by Vibration Test vol.35, pp.2, 2015, https://doi.org/10.12652/Ksce.2015.35.2.0255
  5. An Experimental Study on Shear Friction Behavior of RC Slab and SC(Steel Plate Concrete) Wall Structure with Connection Joint vol.25, pp.6, 2013, https://doi.org/10.7781/kjoss.2013.25.6.623
  6. A Study on Out-of-Plane Flexural Behavior of the Structure with a Vertical Plane Connection between a Reinforced Concrete Wall and a Steel Plate Concrete Wall vol.25, pp.1, 2013, https://doi.org/10.7781/kjoss.2013.25.1.093
  7. Shear strength of joints between reinforced concrete slabs and steel-plate–concrete walls vol.171, pp.10, 2018, https://doi.org/10.1680/jstbu.16.00138
  8. 비보강 강판콘크리트 전단벽의 횡하중 성능 및 강도특성에 대한 실험적 평가 vol.16, pp.5, 2012, https://doi.org/10.5000/eesk.2012.16.5.023
  9. 강판 콘크리트 구조 접합부의 설계방식에 따른 검증실험 연구 vol.26, pp.1, 2014, https://doi.org/10.7781/kjoss.2014.26.1.001
  10. Seismic Performance Evaluation of RC Frames Reinforced with Steel-Plate Concrete System vol.33, pp.2, 2012, https://doi.org/10.7781/kjoss.2021.33.2.119