Sizing System for Medical Compression Stockings -Focus on Imported Medical Compression Stockings in the Korean Market-

의료용 압박스타킹의 사이즈 체계에 관한 연구 -한국 시장에서의 수입 의료용 압박스타킹을 중심으로-

  • Do, Wol-Hee (Dept. of Clothing & Textiles, Chonnam National University/The Research Institute of Human Ecology, Chonnam National University) ;
  • Kim, Nam-Soon (Dept. of Clothing & Textiles, Chonnam National University/The Research Institute of Human Ecology, Chonnam National University)
  • 도월희 (전남대학교 의류학과/전남대학교 생활과학연구소) ;
  • 김남순 (전남대학교 의류학과/전남대학교 생활과학연구소)
  • Received : 2012.05.09
  • Accepted : 2012.07.10
  • Published : 2012.08.31

Abstract

This study provides size information on current imported medical compression stockings in Korea. A total 20 brands from 6 countries imported and sold in the Korean on-off line markets were selected for this study and the sizing system of medical compression stockings was researched. The results of this study were as follows: there were size differences among different USA brands according to product type or compression class of medical compression stockings. To establish the sizing system for medical stockings of the German brands, the basic body measurements standard was set as cA, cY, cB, cB, cC, cD, cE, cF, cG, cH, cT, lD, lG, and lT. Italian brands developed the sizing system for medical compression stockings by compression class. In the Swiss brands, size types were sub-divided as 'Normal', 'Plus', 'Short', and 'Long'. The sizing 1 were confined within very narrow limits. There were differences of the basic body measurements between Taiwan brands. The results of the comparison of the size range of the imported brands with Size Korea (KATS, 2010) by two-way size distribution shows that the sizing systems of the imported brands were unsuitable for Koreans. To enhance the suitability of the sizing system for medical compression stockings, a new sizing system for Korean adult males and females needs to be established.

Keywords

References

  1. Do, W. H., & Kim, N. S. (2011). A comparision of imported medical compression stockings by country. Proceedings of the Korean Society of Clothing and Textiles, Fall Conference, Korea, 232.
  2. Do, W. H., & Kim, N. S. (2012). A comparision of imported medical compression stockings by manufacturing country. Journal of the Korean Society of Clothing and Textiles, 36(3), 335-345. https://doi.org/10.5850/JKSCT.2012.36.3.335
  3. Hohlbaum, G., Milde, L., Schmitz, R., & Weber, G. (1989). The medical compression stocking. New York: John Wiley & Sons Canada.
  4. Johnson, G., Jr., Kupper, C., Farrar, D. J., & Swallow, R. T. (1982). Graded compression stockings: Custom vs noncustom. Archives of Surgery, 117(1), 69-72. https://doi.org/10.1001/archsurg.1982.01380250047011
  5. Medizinische Kompressionssrtumpfe, Gutesicherung RALGZ 387. (2008). DEUTSCHES INSTITUT FUR GUTESICHERUNG UND KENNZEICHNUNG E.V. Retrieved November 17, 2011, from http://www.gzg-kompressionsstruempfe.de/uploads/media/RALGZ_387_1_Ausgabe_01.08.pdf
  6. Mitchel, P. G., John, J. B., & Jean-Jrme, G. (2009). Sclerotherapy-treatment of varicose and telangiectatic leg vein (S. H. Kang, Trans.). Seoul: Gabon. (Original work published 2007)
  7. Korean Agency for Technology and Standards. (2010). The 6th Size Korea. Size Korea. Retrieved January 6, 2012, from http://sizekorea.kats.go.kr
  8. Swedborg, I. (1984). Effects of treatment with an elastic sleeve and intermittent pneumatic compression in post-mastestomy patients with lymphoedema of the arm. Scandinavian Journal of Rehabilitation Medicine, 16(1), 35-41.

Cited by

  1. Development of Sizing System for Medical Compression Stocking of Korean Men vol.19, pp.1, 2017, https://doi.org/10.5805/SFTI.2017.19.1.61