DOI QR코드

DOI QR Code

Physical Properties of 50MPa and 80MPa Ternary High Strength Concretes before and after Concrete Pumping

  • Lee, Bum-Sik (Construction Technology Reserch Dept., Land & Housing Institute) ;
  • Kim, Seong-Deok (Dept. of Architectural Engineering. Dankook University Graduate School) ;
  • Jun, Myoung-Hoon (Construction Technology Reserch Dept., Land & Housing Institute) ;
  • Park, Sung-Sik (Construction Technology Reserch Dept., Land & Housing Institute) ;
  • Park, Su-Hee (Machinery, Metals & Construction Team, Korea Institute of Patent Information) ;
  • Jung, Sang-Jin (Dept. of Architectural Engineering. Dankook University Graduate School)
  • Received : 2011.09.08
  • Accepted : 2012.05.21
  • Published : 2012.08.20

Abstract

At the Korea Land and Housing Corporation(LH), concretes with high design strength of 50 MPa and 80 MPa that are composed only of ordinary Portland cement, blast furnace slag, and fly ash are developed. To determine whether the developed high strength concretes have the same properties when they are produced in batch plant(B/P) condition in the ready mixed concrete plant, and as existing high strength concretes, field tests are performed and material properties are evaluated. To investigate the material properties of the high strength concretes before and after pumping, compressive strength, flowability, air content, hydration temperature, pumping and compactability are evaluated. In field tests, before and after pumping, flowability satisfied the relevant criteria. In terms of air content, while it was slightly decreased after pumping, it satisfied the requirements. Hydration temperature criteria were satisfied, and compactability was excellent as well. The study found that the developed ternary high strength concretes have the same properties as existing high strength concretes. They can also be useful for the construction of high-rise buildings, as they are economical.

Keywords

References

  1. Ministry of Land, Transport and Maritime Affairs(MLTM). Application of High Strength Concrete to High-rise Residential Building(III). Seongnam (Korea): LH; 2008. 213 p. Korean.
  2. Concrete Institute of Korea. Korea Structural Concrete Design Code, Seoul (Korea): Kimoondang; 2007. 523 p. Korean.
  3. Concrete Institute of Korea. concrete standard specification. Seoul (Kora): Concrete Institute of Korea; 2009. 762 p. Korean.
  4. Architecture Institute of Japan. Japanese Architectural Standard Specification 5. Tokyo (Japan): Architecture Institute of Japan; 2009. 916 p. Japanese.
  5. Kim WJ, Lee GC, Kim KK, Jung SJ, Lee JI. Kim HB. A study on 80㎫ high strength concrete pumping for the construction of high rise buildings. Kim Woo Jae. Proceeding Annual Conference of the Architectural institute of Korea Structure & Construction; 2007; Chunbuk University. Seoul (Korea); Architrcturl Institute of Korea: 2007. p. 491-4.
  6. Choi SM, Lee BS, Bae KS, Kim SY. Park SH. Rheological Characteristics of Fiber-Reinforced High-Strength AFR Concrete. Proceedings of the Korea Concrete Institute; 2009; Busan Bexco. Seoul (Korea); Korea Concrete Institute: 2009. p. 543-44.
  7. Ko JH, Moon HJ, Seok WK, Park SJ, Kim HJ. A study on the 1:1 full scale core wall mock-up test of high strength concrete performed by testing pumpability. Journal of the architectural institute of Korea Structure & Construction. 2008 Aug;24(8):203-10.
  8. Kim HY, Seo CH. An Experimental Study on the Physical Properties by Compressive Strength Areas of Concrete at High Temperature. Journal of the architectural institute of korea Structure & Construction. 2004 Nov;20(11): 75-82.
  9. Song H, Chu YS, Lee JK. Strength and Deformation of High Strength Concrete in High Temperatures. Proceeding Annual Conference of the Architectural institute of Korea Structure & Construction; 2006; Daegu Exco (Korea). Seoul (Korea); Architrcturl Institute of Korea: 2006. p. 505-8.
  10. Kim JM. A Study on Basic Properties of Ultra High-Strength Concrete according to Kinds of Cement and Admixture [dissertation]. Yongin (Korea): University of Dankook; 2007. p. 85.
  11. Son HJ, Noh SK, Kim SH, Han MC, Baek JH, Han CG. Shrinkage and Strength of Concrete Incorporating Blast-furnace Slag. Proceeding Annual Conference of the Architectural institute of Korea Structure & Construction; 2008; Dankook University Seoul (Korea); The Korea Institue of Building Construction: 2008. p. 99-102.
  12. Kwon YJ. An experimental study on the Carbonation and Drying Shrinkage of High Strength Concrete According to Kinds and Ratios of Mineral Admixtures. Journal of the korea institute of building construction. 2003 Sep;3(3):127-33. https://doi.org/10.5345/JKIC.2003.3.3.127

Cited by