DOI QR코드

DOI QR Code

A Study on Oil's Contamination Detection System using Optical Fiber Sensor

광섬유 센서를 이용한 오일 오염도 검사시스템 연구

  • Received : 2011.08.22
  • Accepted : 2012.04.21
  • Published : 2012.08.15

Abstract

This study investigates the detection system of oil pollution level using single optical fiber sensor. This study focus on sensing of oil pollution by moisture and iron powder which are representatives of oil pollution factor. In addition, It is placed that the water and iron powder as an oil pollution factor in the oil tank which is the oil circulation in. The oil pollution detection system was measured by the changing of intensity of light and sensing gap. The result of this experimentation not only confirmed the contamination by moisture volume in the oil tank from the section 190ppm to 540ppm, but also monitored the contamination by iron volume from the section 1200ppm to 3500ppm. This study confirmed effectiveness of this detection system using optical fiber sensor. There is expectations of measuring another section by various optical fiber sensor.

Keywords

References

  1. Jeong, S. H., Park, S. J., Hong, W. S., Kim, Y. J., and Koo, K. H., 2003, "An Experimental Study on the Dewatering from the Waste Lubrication Oil by Vacuum Evaporation," Journal of the Korea Society of Energy Engineering, Vol. 12, No. 3, pp. 216-222.
  2. Cho, S. Y., Jang, C. J., Kong, H., Yoon, E. -S., and Han, H. G., 2001, "An Experimental Study on the Light Transmission Characteristics with Oil Contamination," Journal of the Korea Society of Tribologists and Lubrication Engineers, Vol. 17, No. 6, pp. 482-489.
  3. Shin, W. C., 2006, A Design of Multi-mode Optical Fiber Displacement Sensor by Transmitting Light Irradiance Distribution Modeling, A Thesis for a Doctorate, Chugnam National University, Republic of Korea.
  4. Hulst, H. C. van de, 1981 Light Scattering by Small Particle, Wiley, New York, pp. 470.
  5. Kang, D. H., Hong, J. H., Shin, W. C., Song, D. S., and Jang, T. S., 2007, "A Study of the Non-counter using Optical Fiber Sensor," Journal of the Korea Society of Manufacturing Technology Engineers, Vol. 16, No. 6, pp. 231-236.
  6. Hwang J. H., Kim, J. H., and Kim, Y. J., 2007, "Transient Analysis of Flow Fields in an Agitator with a Draught Tube," Journal of the Korea Fluid Machinery Association, Vol. 10, No. 1, pp. 56-63. https://doi.org/10.5293/KFMA.2007.10.1.056
  7. Kim, D. K., Bae, S. T., Kim, J. H., Kim, O. K., and Lee, Y. H., 2006, "A Study about Choice of Industrial Mixer's Impeller Type Concentration Measurement Method and PIV," Journal of the Korea Society of Marine Engineering, Vol. 30, No. 3, pp. 413-419.
  8. No, H. Y., 2007, "The Select Method of Agitator," Journal of the Korea Fluid Machinery Association, Vol. 10, No. 3, pp. 55-66. https://doi.org/10.5293/KFMA.2007.10.3.055
  9. Cho, S. Y., 2002, A Study of Machine Condition Monitoring Technique by Oil Contamination Measurement, A Thesis for a Master's Degree, The University of Seoul, Republic of Korea.
  10. Joung, S. H., 2007, A Study of Optical Absorption Spectroscopy for Determining Carbon Nanotube Concentration in Solution, A Thesis for a Master's Degree, Sungkyunkwan University, Republic of Korea.