DOI QR코드

DOI QR Code

연성 이종 재료 시료의 상온 절편 제작법

Sample Preparation of Ductile Heterogeneity Materials by Ultramicrotomy

  • Chae, Hee-Su (Division of Electron Microscopic Research, Korea Basic Science Institute (KBSI)) ;
  • Kweon, Hee-Seok (Division of Electron Microscopic Research, Korea Basic Science Institute (KBSI)) ;
  • Je, A-Reum (Division of Electron Microscopic Research, Korea Basic Science Institute (KBSI)) ;
  • Lee, Seok-Hoon (Division of Electron Microscopic Research, Korea Basic Science Institute (KBSI)) ;
  • Kim, Jin-Gyu (Division of Electron Microscopic Research, Korea Basic Science Institute (KBSI))
  • 투고 : 2012.02.15
  • 심사 : 2012.03.26
  • 발행 : 2012.03.31

초록

For TEM study of biological samples or polymers that are contained in organic structure, it is often required that the sample is prepared by using ultramicrotome and stained with proper agents to increase the contrast of organic structure. In this study, we investigated an efficient TEM sample preparation method for ductile heterogeneity material by using ultramicrotomy. Cryo-ultramicrotomy is a suitable method that is capable of rendering sample hardness for various ductile materials. However, it has several factors to consider, such as experimental cost, working time and finding the optimal staining conditions. To satisfy these considerations, we prepared TEM sample by using ultramicrotome without cryofunction, and secured the sample hardness by applying the staining process prior to ultrathin sectioning. The cross-linked polyethylene structure in the sample was stained with the 2% $RuO_4$ solution in a sealed test tube for 24 hours at $4^{\circ}C$. After the sample staining, ultrathin sections of sample were prepared using ultramicrotome. As a result, it was revealed that the difficulties associated with staining of ultrathin sections prepared by low-temperature conditions were improved. In addition, appropriate staining depth of sample could be selected for sectioning process. The quality of TEM sample obtained by using this method was better than that of cryo-ultramicroscopy. Finally, it is expected that our method could be effectively applied in TEM sample preparation for a variety of nano-bio convergence materials.

키워드

참고문헌

  1. Ayache J, Luc B, Jacqueline B, Gabrielle E, Daniele L: Sample preparation handbook for transmission electron microscopy. Springer, New York, pp. 201-228, 2009.
  2. Bozzola JJ and Russell LD: Electron Microscopy. Jones & Bartlett Learning, Boston, pp. 72-82, 1992.
  3. Chou TM, Prayoonthong P, Aitouchen A, Libera M: Nanoscale artifacts in $RuO_{4}$-stained poly(styrene). Polymer 43(7) : 2085- 2088, 2002. https://doi.org/10.1016/S0032-3861(01)00767-4
  4. Jeong KU: Polymer structure analysis utilizing TEM and SAED. Polymer Science and Technology 20(2) : 180-185, 2009. (Korean)
  5. Kato K: The osmium tetroxide procedure for light and electron microscopy of ABS plastics. Polymer Engineering and Science 7(1) : 38-39, 1967. https://doi.org/10.1002/pen.760070110
  6. Okamoto T, Ishida M: Growth of Lamellar at the Semicon-Interface in XLPE Power Cables. 4th International Conference on Properties and Application of Dielectric materials, p. 455-458, Brisbane, Austrailia, 1994.
  7. Sawyer LC, Grubb DT, Meyers GF: Polymer Microscopy. Champman and Hall, New York, pp. 130-247, 2008.
  8. Shim SI, Cho DH, Youn BH: The microstructural analysis of XLPE insulation for power cable. International Conference on Electrical Engineering 2004, p. 380-383, Sapporo, Japan, 2004.
  9. Vitali R, Montani E: Ruthenium tetroxide as a staining agent for unsaturated and saturated polymers. Polymer 21(10) : 1220-1222, 1980. https://doi.org/10.1016/0032-3861(80)90091-9
  10. Yoo TJ: Insulation materials for power cable. Polymer Science and Technology 9(5) : 381-388, 1998. (Korean)
  11. Youn BH, Cho DH, Shim SI: Improvement of breakdown strength by additives and curing conditions on XLPE insulation for power cable. IEEE transactions on Dielectrics and Electrical Insulation, p. 347-350, New Jersey, USA, 2004.