The objective of this study is to evaluate the influence of the blind position on the energy performance with a double-skin facade system. First, we measured indoor and intermediate space temperature from 4th of June to 10th of July. And EnergyPlus simulation was performed during the same period. After that, MBE & Cv(RMSE) were analyzed to validate the measurement and simulation results. As a results, the cooling load derived by EnergyPlus program with exterior blind is 54.9%(peak load 39.8%) smaller than that of no blind. And the cooling load derived by EnergyPlus with interior blind is 28.2%(peak load 18.1%) smaller than that of no blind. So, we can see that exterior blind has better thermal performance than interior blind.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. Maria Wall and Helena Bulow-Hube, Solar Protection in Buildings Part 2: 2000-2002, Lund University, 2003
  2. Elisabeth Gratia, The most efficient position of shading devices in a double-skin facade, Energy and Buildings 39, 2007
  3. 이소연, 김강수 외, 주거건물용 이중외피 시스템의 블라인드 조절에 따른 에너지 성능평가에 관한 연구, 한국태양에너지학회 논문집, 제30권 제6호, 2010. 12
  4. M.H.Sherman and D.T.Grimsrud, Infiltration - Pressurization Correlation: Simplified Physical Modeling, Lawrence Berkeley Laboratory, 1980
  5. Peter G. Loutzenhiser, Emperical validations of solar gain models for a glazing unit with exterior and interior blind assemblies, Energy and Buildings 40, 2008
  6. J.H. Klems and J.L. Warner, Solar Heat Gain coefficient of Complex Fenestrations With a Venetian Blind for Differing Slat Tilt Angles, ASHRAE Transactions 103(1), 1997
  7. ENERGYPLUS, Input Output Reference, Lawrence Berkeley National Laboratory, 2010. 11
  8. ASHRAE, AHSHRAE HANDBOOK FUNDAMENTALS, 1993
  9. M&V guidelines, Measurement and verification for federal energy projects version 3.0, US Department of Energy, 2008
  10. 한국공업표준협회, 한국공업규격집 KS A3011, KS 조도기준, 1998