CASES OF HEMOLYTIC ANEMIA WITH PERIPROSTHETIC LEAKS EVALUATED BY REAL-TIME 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
- Chung, Eui-Jong (Department of Cardiovascular Medicine, Konkuk University Medical Center) ;
- Kim, Tae-Yop (Department of Anesthesiology, Konkuk University Medical Center) ;
- Hwang, Jong Min (Department of Internal Medicine, Pusan National University College of Medicine) ;
- Kim, Sang-Phil (Department of Cardiothoracic Surgery, Pusan National University College of Medicine) ;
- Yang, Hyun Suk (Department of Cardiovascular Medicine, Konkuk University Medical Center)
- 투고 : 2011.10.06
- 심사 : 2012.02.16
- 발행 : 2012.03.27
초록
Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images.