References
- DeBoer J. Edentulous implants: overdenture versus fixed. J Prosthet Dent 1993;69:386-90. https://doi.org/10.1016/0022-3913(93)90186-R
- Sadowsky SJ. The implant-supported prosthesis for the edentulous arch: design considerations. J Prosthet Dent 1997;78:28-33. https://doi.org/10.1016/S0022-3913(97)70084-2
- Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416. https://doi.org/10.1016/S0300-9785(81)80077-4
- Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent 2006;15:24-34. https://doi.org/10.1097/01.id.0000202419.21665.36
- Kurtzman GM. Lab techniques for use of the locator attachment in bar-overdenture applications. TeamWork 2008;1:72-8.
- Schneider AL, Kurtzman GM. Bar overdentures utilizing the Locator attachment. Gen Dent 2001;49:210-4.
- Naert I, De Clercq M, Theuniers G, Schepers E. Overdentures supported by osseointegrated fixtures for the edentulous mandible: a 2.5-year report. Int J Oral Maxillofac Implants 1988;3:191-6.
- Celik G, Uludag B. Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures. J Prosthet Dent 2007;97:229-35. https://doi.org/10.1016/j.prosdent.2007.02.006
- Pasciuta M, Grossmann Y, Finger IM. A prosthetic solution to restoring the edentulous mandible with limited interarch space using an implant-tissue-supported overdenture: a clinical report. J Prosthet Dent 2005;93:116-20. https://doi.org/10.1016/j.prosdent.2004.09.024
- Lee CK, Agar JR. Surgical and prosthetic planning for a two-implant- retained mandibular overdenture: a clinical report. J Prosthet Dent 2006;95:102-5. https://doi.org/10.1016/j.prosdent.2005.11.017
- Chung KH, Chung CY, Cagna DR, Cronin RJ Jr. Retention characteristics of attachment systems for implant overdentures. J Prosthodont 2004;13:221-6. https://doi.org/10.1111/j.1532-849X.2004.04042.x
Cited by
- Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report vol.53, pp.3, 2015, https://doi.org/10.4047/jkap.2015.53.3.207
- Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment vol.8, pp.4, 2016, https://doi.org/10.4047/jap.2016.8.4.313
- 임플란트 피개의치를 위한 Locator 어태치먼트: 문헌 고찰 vol.29, pp.2, 2012, https://doi.org/10.14368/jdras.2013.29.2.127
- 상악 부분 무치악 환자에서 Milled Bar와 Locator를 이용한 임플란트 융합 국소의치수복 증례 vol.58, pp.2, 2012, https://doi.org/10.4047/jkap.2020.58.2.137
- Locator R-Tx 부착 장치를 이용한 하악 임플란트 피개 의치 보철수복 증례 vol.58, pp.4, 2012, https://doi.org/10.4047/jkap.2020.58.4.335
- 임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교 vol.59, pp.2, 2012, https://doi.org/10.4047/jkap.2021.59.2.173