DOI QR코드

DOI QR Code

Seismic Evaluation of RC Special Shear Wall with Improved Reinforcement Details in Boundary Elements

경계요소의 횡보강근 상세를 개선한 RC 특수전단벽의 내진성능 평가

  • 천영수 (한국토지주택공사 토지주택연구원)
  • Received : 2012.04.05
  • Accepted : 2012.04.18
  • Published : 2012.04.30

Abstract

This paper summarizes the seismic performance of two shear walls with different reinforcement details in boundary elements. One is a special shear wall designed by KBC2009 and the other is a shear wall with improved reinforcement details in boundary elements, which is a newly proposed type of special shear wall. Experimental tests under cyclic reversed loading were carried out with two 2/3 scale shear walls which were modelled from the lower part of seismic-resisting shear wall in 22-stories wall-slab apartment building. The experimental results show that seismic performance of shear wall with improved reinforcement details was almost similar to that of special shear wall with respect to the moment-drift ratio. However, energy dissipation capacity and ductility were slightly different. Also, shear wall with improved reinforcement details in boundary elements satisfied the inter-story drift limit of 1.5% from KBC2009.

이 논문은 KBC2009에서 규정하고 있는 RC 특수전단벽과 시공성 개선을 목적으로 제안된 경계요소 내 완화된 배근상세를 갖는 특수전단벽과의 비교 실험결과를 제시하고 있다. 연구목적에 따라 22층 벽식구조 아파트로부터 모델링된 최하층 벽체가 2/3크기로 축소되어 2개의 실험체가 제작되었으며, 일정축력 하에서 반복가력 실험이 실시되었다. 실험결과, 완화된 배근상세를 따르는 특수전단벽체은 KBC2009의 배근상세를 따르는 특수전단벽체와 등가점성 감쇠비를 통해 계산된 에너지소산능력 및 연성도에서는 약간의 차이를 보이고 있으나, 하중-변위 측면에서는 매우 유사한 능력을 보이는 것으로 나타났다. 또한, 현행 설계기준에서 제시하고 있는 1.5% 수준의 층간횡변위비 조건을 충분히 만족하고 있음을 확인하였다.

Keywords

References

  1. 대한건축학회(2009), 건축구조기준 및 해설(KBC2009).
  2. 조순호, 김두영, 천영수(1993), 전단벽의 양단부 기둥식 보강기법 연구, 대한주택공사.
  3. 천영수, 김상연, 이완철(2011), 구조시스템 높이제한 규정 완화를 위한 준특수전단벽 상세 개발, 토지주택연구원.
  4. ASCE (2005), Minimum design loads for buildings and other structures, American Society of Civil Engineers.
  5. American Concrete Institute Committee 318 (2008), Building code requirements for structural concrete, ACI 318-08 and ACI 318R-08, Farminton Hills, Michigan, USA.
  6. Wallace, J. W. and J. P. Moehle (1992), "Ductility and detailing requirements of bearing wall buildings", Journal of structural engineering, ASCE, 118(6): 1625-1644. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:6(1625)
  7. Thomson IV, J. H. and J. W. Wallace (1995), Displacement-based design of RC structural wall : An experimental investigation of walls with rectangular and T-shaped cross-sections, Report No. Cu/Cee-95-06, Department of Civil and Environment Engineering at Clark university.
  8. ACI Innovation Task Group 1 and Collaborators (2001), Acceptance Criteria for Moment Frame Based on Structural Testing (ACI ITG/T1.1-01) and Commentary (ACI ITG/T1.1R-01), American Concrete Institute, Farmington Hills, MI.