DOI QR코드

DOI QR Code

고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구

Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system

  • 김동혁 (인제대 대학원 의용공학과) ;
  • 고락길 (한국전기연구원 초전도연구센터) ;
  • 강부민 (한국전기연구원 초전도연구센터) ;
  • 하동우 (한국전기연구원 초전도연구센터) ;
  • 손명환 (한국전기연구원 초전도연구센터) ;
  • 문치웅 (인제대 의용공학과)
  • 투고 : 2012.02.03
  • 심사 : 2012.03.21
  • 발행 : 2012.03.31

초록

The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

키워드

참고문헌

  1. C. Chen and D. I. Hoult, "Biomedical Magnetic Resonance Technology" New York: Adam Hilger, 1989.
  2. K. H. Lee, M. C. Cheng, K. C. ChanK. K. Wong, Simon S. M. Yeung, K. C. Lee,Q. Y. Ma, and Edward S. Yang, "Performance of Large-Size Superconducting Coil in 0.21T MRI System," IEEE Transactions on Biomedical Engineering, vol. 51, no. 11, November, 2004.
  3. R. Black, T. A. Early, P. B. Roemer, O. M. Mueller, A. Mogro-Campero, L. G .Turner, and G. A. Johnson, "A high-temperature superconducting receiver for nuclear magnetic resonance microscopy," Science, vol. 259, no. 5096, pp. 793-795, Feb. 1993. https://doi.org/10.1126/science.8430331
  4. Q. Ma, "RF applications of high temperature superconductors in MHz range," IEEE Trans. Appl. Supercond., vol. 9, no. 2, pp. 3565-3568, Jun. 1999. https://doi.org/10.1109/77.783800
  5. Haase A, W Hanicke, J Frahm, "The influence of experimental parameters in surface-coil," NMR J. Magn. Reson. vol. 56, pp. 401-402, 1984
  6. MCCheng, B P Yan1, K H Lee, QYMa and E S Yang, A high temperature superconductor tape RF receiver coil for a low field magnetic resonance imaging system, Supercond. Sci. Technol, vol. 18, pp. 1100-1105, 2005. https://doi.org/10.1088/0953-2048/18/8/013
  7. Hill H D W, "Improved sensitivity of NMR spectroscopy probes by use of high temperature superconductive detection coils," IEEE Trans. Appl. Supercond, vol. 7 pp. 3750-3755, 1997 https://doi.org/10.1109/77.622233
  8. G. Grasso, A. Malagoli, N. Scati, P. Guasconi, S. Roncallo, and A. S. Siri, "Radio frequency response of Ag-sheathed (Bi, Pb)2Sr2Ca2Cu3O10+x superconducting tapes," Supercond. Sci. Technol., vol. 13, no. 10, pp. L15-L18, Oct. 2000. https://doi.org/10.1088/0953-2048/13/10/102
  9. Hong-Chang Yang, Kuen-Lin Tsai, Ji-Cheng Chen,Chiu-Hsien Wu, Herng-Er Horng, Jyh-Horng Chen and Li-Wei Kuo, "High-Tc superconducting surface coils for improving the image quality on a 3T imager," Supercond. Sci. Technol. vol. 20 pp. 777-780, 2007. https://doi.org/10.1088/0953-2048/20/8/009
  10. In-Tsang Lin, Hong-Chang Yang, Chang-Wei Hsieh, Tun Jao and Jyh-Horng Chen, "Human hand imaging using a 20cm high-temperature superconducting coil in a 3T mangetic resonance imaging system," J. Appl. Phys, vol. 107, pp. 124701, 2010. https://doi.org/10.1063/1.3431538
  11. Bracanovic D, Esmail AA, Penn SJ, "Surface YBa2Cu3O7 receive coils for low field MRI,." IEEE Trans Appl Supercond vol. 11, pp. 2422-2424, 2001. https://doi.org/10.1109/77.920351
  12. Ginefri JC, Darrasse L, Crozat P. "High-temperature superconducting surface coil for in vivo microimaging of the human skin," Magn Reson Med, vol. 45, pp. 376-382, 2001. https://doi.org/10.1002/1522-2594(200103)45:3<376::AID-MRM1049>3.0.CO;2-R
  13. Darko Kajfez and Eugene J. Hwan, "Q-factor Measurement with Network Analyzer," IEEE Trans Microwave theory and techniques, vol. Mn-32, no. 7, July 1984.