References
- Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410. https://doi.org/10.1016/S0022-3913(83)80101-2
- Johns RB, Jemt T, Heath MR, Hutton JE, McKenna S, McNamara DC, van Steenberghe D, Taylor R, Watson RM, Herrmann I. A multicenter study of overdentures supported by Branemark implants. Int J Oral Maxillofac Implants 1992;7:513-22.
- Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH Jr, Polizzi G, Zarb GA, Herrmann I. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991;6:29-36.
- Andersson B, Odman P, Lindvall AM, Lithner B. Single-tooth restorations supported by osseointegrated implants: results and experiences from a prospective study after 2 to 3 years. Int J Oral Maxillofac Implants 1995;10:702-11.
- Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
- Misch CE. Principles for screw-retained prostheses. In: Misch CE, ed. Contemporary implant dentistry. Missouri; CV Mosby, 1999.
- Bickford JH. An introduction to the design and behavior of bolted joints. New York; Marcel Dekker; 1995.
- Jemt T. Customized titanium single-implant abutments: 2-year follow-up pilot study. Int J Prosthodont 1998;11:312-6.
- Sundh A, Sjogren G. A study of the bending resistance of implantsupported reinforced alumina and machined zirconia abutments and copies. Dent Mater 2008;24:611-7. https://doi.org/10.1016/j.dental.2007.05.021
- Wu T, Liao W, Dai N, Tang C. Design of a custom angled abutment for dental implants using computer-aided design and nonlinear finite element analysis. J Biomech 2010;43:1941-6. https://doi.org/10.1016/j.jbiomech.2010.03.017
- Kim S, Kim HI, Brewer JD, Monaco EA Jr. Comparison of fracture resistance of pressable metal ceramic custom implant abutments with CAD/CAM commercially fabricated zirconia implant abutments. J Prosthet Dent 2009;101:226-30. https://doi.org/10.1016/S0022-3913(09)60043-3
- Henriksson K, Jemt T. Evaluation of custom-made procera ceramic abutments for single-implant tooth replacement: a prospective 1-year follow-up study. Int J Prosthodont 2003;16:626-
- Lang LA, Sierraalta M, Hoffensperger M, Wang RF. Evaluation of the precision of fit between the Procera custom abutment and various implant systems. Int J Oral Maxillofac Implants 2003;18:652-8.
- Magne P, Oderich E, Boff LL, Cardoso AC, Belser UC. Fatigue resistance and failure mode of CAD/CAM composite resin implant abutments restored with type III composite resin and porcelain veneers. Clin Oral Implants Res 2011;22:1275-81. https://doi.org/10.1111/j.1600-0501.2010.02103.x
- Magne P, Paranhos MP, Burnett LH Jr, Magne M, Belser UC. Fatigue resistance and failure mode of novel-design anterior single- tooth implant restorations: influence of material selection for type III veneers bonded to zirconia abutments. Clin Oral Implants Res 2011;22:195-200. https://doi.org/10.1111/j.1600-0501.2010.02012.x
- Kreissl ME, Gerds T, Muche R, Heydecke G, Strub JR. Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clin Oral Implants Res 2007;18:720-6. https://doi.org/10.1111/j.1600-0501.2007.01414.x
- Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995;10:529-36.
- Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001;86:24-32. https://doi.org/10.1067/mpr.2001.116230
- Cibirka RM, Nelson SK, Lang BR, Rueggeberg FA. Examination of the implant-abutment interface after fatigue testing. J Prosthet Dent 2001;85:268-75. https://doi.org/10.1067/mpr.2001.114266
- Breeding LC, Dixon DL, Nelson EW, Tietge JD. Torque required to loosen single-tooth implant abutment screws before and after simulated function. Int J Prosthodont 1993;6:435-9.
- Dixon DL, Breeding LC, Sadler JP, McKay ML. Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent 1995;74:270-8. https://doi.org/10.1016/S0022-3913(05)80134-9
- Carlsson GE, Haraldson T. Functional response. In: Branemark PI. Zarb GA, Albrektsson T. (eds). Tissue integrated prostheses. Osseointegration in clinical dentistry. 4th ed. Chicago; Quintessence; 1986. p. 74-8.
- Bates JF, Stafford GD, Harrison A. Masticatory function - a review of the literature. III. Masticatory performance and efficiency. J Oral Rehabil 1976;3:57-67. https://doi.org/10.1111/j.1365-2842.1976.tb00929.x
- Richter EJ. In vivo vertical forces on implants. Int J Oral Maxillofac Implants 1995;10:99-108.
- Mericske-Stern R, Zarb GA. In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants. Clin Oral Implants Res 1996;7:153-61. https://doi.org/10.1034/j.1600-0501.1996.070209.x
- Patterson EA, Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 1992;7:26-33.
- Jaarda MJ, Razzoog ME, Gratton DG. Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws. Implant Dent 1994;3:17-21. https://doi.org/10.1097/00008505-199404000-00002
- Mitrani R, Nicholls JI, Phillips KM, Ma T. Accuracy of electronic implant torque controllers following time in clinical service. Int J Oral Maxillofac Implants 2001;16:394-9.
- Cantwell A, Hobkirk JA. Preload loss in gold prosthesis-retaining screws as a function of time. Int J Oral Maxillofac Implants 2004;19:124-32.
- Gutierrez J, Nicholls JI, Libman WJ, Butson TJ. Accuracy of the implant torque wrench following time in clinical service. Int J Prosthodont 1997;10:562-7.
- Kim DG, Park CJ, Cho LR. Comparison of accuracy of implant torque controllers. J Korean Acad Stomatognathic Func Occl 2008;24:157-68.
Cited by
- A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment vol.51, pp.4, 2013, https://doi.org/10.4047/jkap.2013.51.4.276
- 임플란트 고정체와 지대주의 체결방식에 따른 스크류 풀림토크에 관한연구 vol.35, pp.3, 2013, https://doi.org/10.14347/kadt.2013.35.3.201
- Mechanical Complications of Posterior Implant Restorations using CAD/CAM Titanium Customized Abutments: A Retrospective Study vol.23, pp.3, 2012, https://doi.org/10.32542/implantology.2019012