Update the finite element model of Canton Tower based on direct matrix updating with incomplete modal data

  • Lei, Y. (Department of Civil Engineering, Xiamen University) ;
  • Wang, H.F. (Department of Mechanical & Electrical Engineering, Xiamen University) ;
  • Shen, W.A. (Department of Civil & Structural Engineering, The Hong Kong Polytechnic University)
  • 투고 : 2012.03.23
  • 심사 : 2012.06.25
  • 발행 : 2012.10.25

초록

In this paper, the structural health monitoring (SHM) benchmark problem of the Canton tower is studied. Based on the field monitoring data from the 20 accelerometers deployed on the tower, some modal frequencies and mode shapes at measured degrees of freedom of the tower are identified. Then, these identified incomplete modal data are used to update the reduced finite element (FE) model of the tower by a novel algorithm. The proposed algorithm avoids the problem of subjective selection of updated parameters and directly updates model stiffness matrix without model reduction or modal expansion approach. Only the eigenvalues and eigenvectors of the normal finite element models corresponding to the measured modes are needed in the computation procedures. The updated model not only possesses the measured modal frequencies and mode shapes but also preserves the modal frequencies and modes shapes in their normal values for the unobserved modes. Updating results including the natural frequencies and mode shapes are compared with the experimental ones to evaluate the proposed algorithm. Also, dynamic responses estimated from the updated FE model using remote senor locations are compared with the measurement ones to validate the convergence of the updated model.

키워드

과제정보

연구 과제 주관 기관 : National Natural Science Foundation of China (NSFC)

참고문헌

  1. Ahmadian, H., Gladwell, G.M.L. and Ismail, F. (1997), "Parameter selection strategies in finite element model updating", J. Vib. Acoust., 119(1), 37-45. https://doi.org/10.1115/1.2889685
  2. Brincker, R., Zhang L.M. and Andersen P. (2001), "Modal identification of output-only systems using frequency domain decomposition", Smart Mater. Struct., 10(3), 441-445. https://doi.org/10.1088/0964-1726/10/3/303
  3. Brownjohn, J.M.W., Xia, P.Q., Hao, H. and Xia, Y., (2001), "Civil structure condition assessment by FE model updating: methodology and case studies", Finit. Elem .Anal. Des., 37(10), 761-775. https://doi.org/10.1016/S0168-874X(00)00071-8
  4. Carvalho, J., Biswa N., Datta, B.N., Gupta, A. and Lagadapati, M. (2007), "A direct method for model updating with incomplete measured data and without spurious modes", Mech. Syst. Signal Pr., 21(7), 2715-2731. https://doi.org/10.1016/j.ymssp.2007.03.001
  5. Chen, W.H., Lu, Z.R., Lin, W., Chen, S.H., Ni, Y.Q., Y., Xia, Y. and Laio, W.Y. (2011), "Theoretical and experimental modal analysis of the Guangzhou New TV Tower", Eng. Struct., 33(12), 3628-3646. https://doi.org/10.1016/j.engstruct.2011.07.028
  6. Cheng, L., Xie, H.C. and Spencer, B.F. Jr. (2009), "Optimized finite element model updating method for damage detection using limited sensor information", Smart Struct. Syst., 5(6), 681-697. https://doi.org/10.12989/sss.2009.5.6.681
  7. Friswell, M.I. (2001), "Finite-element model updating using experimental test data: Parametrization and regularization", Philos. T. R. Soc. A., Mathematical, 359(1778), 169-186. https://doi.org/10.1098/rsta.2000.0719
  8. Friswell, M.I. and Mottershead, J.E. (1995), Finite element model updating in structural dynamics, Kluwer Academic Publishers.
  9. Friswell, M.I., Inman, D.J. and Pilkey D.F. (1998), "The direct updating damping and stiffness matrices", AIAA J., 36(3), 4591-493.
  10. Fritzen, C.P., Jannewein, D. and Kiefer, T. (1998), "Damage detection based on model updating methods", Mech. Syst. Signal Pr., 12, 163-186. https://doi.org/10.1006/mssp.1997.0139
  11. Jaishi, B. and Ren,W.X. (2005), "Structural finite element model updating using ambient vibration test results", J. Struct. Eng. - ASCE, 131(4), 617-628. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:4(617)
  12. Link, M. (1999), "Updating of analytical models-review of numerical procedures and application aspects", Proceedings of the Structural Dynamics forum SD2000, Los Alamos.
  13. Kammer, D.C. (1997), "Estimation of structural response using remote sensor locations", J. Guid.Control Dynam., 20(3), 501-508. https://doi.org/10.2514/2.4069
  14. Moller, P.W. and Friberg, O. (1998), "Updating large finite element models in structural dynamics", AIAA J., 36(10), 1861-1868. https://doi.org/10.2514/2.279
  15. Mottershead, J.E. and Friswell M.I. (1993), "Model updating in structural dynamics: a survey", J. Sound Vib., 167(2), 347-375. https://doi.org/10.1006/jsvi.1993.1340
  16. Ni, Y.Q., Xia, Y., Liao, W.Y. and Ko, J.M. (2009), "Technology innovation in developing the structural health monitoring system for Guangzhou New TV Tower", Struct.Control Health Monit., 16(1), 73-98. https://doi.org/10.1002/stc.303
  17. Ni, Y.Q., Xia, Y., Lin, W., Chen, W.H. and Ko, J.M. (2012), "SHM benchmark for high-rise structures: a reduced-order finite element model and field measurement data", Smart Struct. Syst., in this issue.
  18. Niu, Y., Kraemer, P. and Fritzen, C.P. (2011), "Operational modal analysis for the Guangzhou New TV Tower", Proceedings of the Society for Experimental Mechanics Series, 7, 211-220.
  19. Overschee, V.P. and De Moor, B. (1996), Subspace Identification for Linear Systems: Theory-implementationapplications, Kluwer Academic Publishers, Dordrecht, The Netherlands.
  20. Weng, S. (2010), A New Substructuring Method for Model Updating of Large-scale Structures, Ph.D. Thesis, Department of Civil and Structural Engineering, The Hong Kong Polytechnic University, Hong Kong.
  21. Yu, E. and Lan, C. (2012), "Seismic damage detection of a reinforced concrete structure by finite element model updating", Smart Struct. Syst., 9(3), 253-271. https://doi.org/10.12989/sss.2012.9.3.253
  22. Ye, J.H. (2011), Finite Element Model Simplification and Updating of Guangzhou New TV Tower, Master Thesis, Sun Yat-Sen University, China.
  23. Yuen, K.V. (2010), "Efficient model correction method with model measurement", J. Eng. Mech. - ASCE, 136(1), 91-99. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000068
  24. Zhang, Q.W., Chang, C.C. and Chang, T.Y.P. (2000), "Finite element model updating for structures with parametric constraints", Earthq. Eng. Struct. D., 29(7), 927-944. https://doi.org/10.1002/1096-9845(200007)29:7<927::AID-EQE955>3.0.CO;2-4

피인용 문헌

  1. Substructural parameters and dynamic loading identification with limited observations vol.15, pp.1, 2015, https://doi.org/10.12989/sss.2015.15.1.169
  2. Operational modal analysis of Canton Tower by a fast frequency domain Bayesian method vol.17, pp.2, 2016, https://doi.org/10.12989/sss.2016.17.2.209
  3. Structural finite element model updating using incomplete ambient vibration modal data vol.57, pp.9, 2014, https://doi.org/10.1007/s11431-014-5619-9
  4. Optimal sensor placement for health monitoring of high-rise structure based on collaborative-climb monkey algorithm vol.54, pp.2, 2015, https://doi.org/10.12989/sem.2015.54.2.305
  5. Damage identification method of girder bridges based on finite element model updating and modal strain energy vol.58, pp.4, 2015, https://doi.org/10.1007/s11431-014-5763-2
  6. Sensor placement optimization in structural health monitoring using distributed monkey algorithm vol.15, pp.1, 2015, https://doi.org/10.12989/sss.2015.15.1.191
  7. An in-time damage identification approach based on the Kalman filter and energy equilibrium theory vol.16, pp.2, 2015, https://doi.org/10.1631/jzus.A1400163
  8. Probability-Based Structural Health Monitoring Through Markov Chain Monte Carlo Sampling vol.16, pp.07, 2016, https://doi.org/10.1142/S021945541550039X
  9. Force monitoring of steel cables using vision-based sensing technology: methodology and experimental verification vol.18, pp.3, 2016, https://doi.org/10.12989/sss.2016.18.3.585
  10. Consistent Multilevel RDT-ERA for Output-Only Ambient Modal Identification of Structures vol.17, pp.09, 2017, https://doi.org/10.1142/S0219455417501061
  11. Structural health monitoring of Shanghai Tower during different stages using a Bayesian approach vol.23, pp.11, 2016, https://doi.org/10.1002/stc.1840
  12. A new swarm intelligent optimization algorithm: Pigeon Colony Algorithm (PCA) vol.18, pp.3, 2016, https://doi.org/10.12989/sss.2016.18.3.425
  13. Analysis and probabilistic modeling of wind characteristics of an arch bridge using structural health monitoring data during typhoons vol.63, pp.6, 2012, https://doi.org/10.12989/sem.2017.63.6.809
  14. Modal identification for superstructure using virtual impulse response vol.22, pp.16, 2019, https://doi.org/10.1177/1369433219862951
  15. Structural model updating of the Gageocho Ocean Research Station using mass reallocation method vol.26, pp.3, 2020, https://doi.org/10.12989/sss.2020.26.3.291
  16. Simulation of Nonstationary Process Using Ensemble Empirical Mode Decomposition and Empirical Envelope Methods vol.24, pp.11, 2012, https://doi.org/10.1007/s12205-020-5478-9
  17. Two-stage Bayesian system identification using Gaussian discrepancy model vol.20, pp.2, 2012, https://doi.org/10.1177/1475921720933523