DOI QR코드

DOI QR Code

A simplified design procedure for seismic retrofit of earthquake-damaged RC frames with viscous dampers

  • Weng, D.G. (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University) ;
  • Zhang, C. (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University) ;
  • Lu, X.L. (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University) ;
  • Zeng, S. (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University) ;
  • Zhang, S.M. (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University)
  • 투고 : 2011.07.03
  • 심사 : 2012.10.27
  • 발행 : 2012.12.10

초록

The passive energy dissipation technology has been proven to be reliable and robust for recent practical applications. Various dampers or energy dissipation devices have been widely used in building structures for enhancing their performances during earthquakes, windstorm and other severe loading scenarios. This paper presents a simplified seismic design procedure for retrofitting earthquake-damaged frames with viscous dampers. With the scheme of designing the main frame and the supplemental viscous dampers respectively, the seismic analysis model of damped structure with viscous dampers and braces was studied. The specific analysis process was described and approach to parameter design of energy dissipation components was also proposed. The expected damping forces for damped frame were first obtained based on storey shear forces; and then they were optimized to meet different storey drift requirements. A retrofit project of a RC frame school building damaged in the 2008 Wenchuan earthquake was introduced as a case study. This building was retrofitted by using viscous dampers designed through the simplified design procedure proposed in this paper. Based on the case study, it is concluded that this simplified design procedure can be effectively used to make seismic retrofit design of earthquake-damaged RC frames with viscous dampers, so as to achieve structural performance objectives under different earthquake risk levels.

키워드

참고문헌

  1. ASCE 7-05 Seismic Provisions (2005), Section 18: Seismic Design Requirements for Structures with Damping Systems, The American Society of Civil Engineers for the Federal Emergency Management Agency, Washington, D. C.
  2. ATC-33.03 (1997), BSSC Guidelines for the Seismic Rehabilitation of Buildings: Seismic Isolation and Energy Dissipation, Applied Technology Council for the Building Seismic Safety Council and the Federal Emergency Management Agency, Redwood City, California.
  3. Clough, R.W. and Penzien, J. (1993), Dynamics of Structures, Second Edition, McGraw Hill Inc., New York.
  4. Dargush, G.F. and Sant, R.S. (2005), "Evolutionary aseismic design and retrofit of structures with passive energy dissipation", Earthq. Eng. Struct. D., 34(13), 1601-1626. https://doi.org/10.1002/eqe.497
  5. EC8 (2003), Euro Code 8: Design of Structures for Earthquake Resistance. General Rules, Seismic Actions and Rules for Buildings, EN1998-1: 2003, British Standards Institution, London.
  6. FEMA 273 (1997), NEHRP Guidelines for the Rehabilitation of Buildings, The Building Seismic Safety Council for the Federal Emergency Management Agency, Washington, D. C.
  7. FEMA 274 (1997), NEHRP Commentary on the Guidelines for the Rehabilitation of Buildings, The Building Seismic Safety Council for the Federal Emergency management Agency, Washington, D. C.
  8. Fu, Y. and Kasai, K. (1998), "Comparative study of frames using viscoelastic and viscous dampers", J. Struct. Eng., Am. Soc. Civil Eng., 124(5), 513-522.
  9. Hanson, R.D. and Soong, T.T. (2001), Seismic Design with Supplemental Energy Dissipation Devices (MNO-8), Earthquake Engineering Research Institute, Oakland, CA.
  10. Housner, G.W., Bergman, L.A., Caughey, T.K., Chassiakos, A.G., Claus, R.O., Masri, S.F., Skelton, R.E., Soong, T.T., Spencer B.F., Jr. and Yao, J.T.P. (1997), "Structural control: past, present and future", J. Eng. Mech., ASCE, 123(9), 897-971. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:9(897)
  11. Hwang, J.S., Wang, S.J., Huang, Y.N. and Chen, J.F. (2007), "A seismic retrofit method by connecting viscous dampers for microelectronics factories", Earthq. Eng. Struct. D., 36(11), 1461-1480. https://doi.org/10.1002/eqe.689
  12. JSSI Manual (2003, 2005, 2007), Design and Construction Manual for Passively Controlled Buildings, Japan Society of Seismic Isolation, Tokyo, Japan, 1st Ed., 2nd Ed., 2nd Ed & 2nd Print.
  13. Kakaletsis, D.J., David, K.N. and Karayannis, C.G. (2011), "Effectiveness of some conventional seismic retrofitting techniques for bare and infilled R/C frames", Struct. Eng. Mech., 39(4), 499-520. https://doi.org/10.12989/sem.2011.39.4.499
  14. Kasai, K. and Kibayashi, M. (2004), "JSSI manual for building passive control technology: Part-1 manual contents and design/analysis methods", Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, Canada, August.
  15. Lavan, O. and Levy, R. (2004), "Optimal design of supplemental viscous dampers for linear framed structures", Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, Canada, August.
  16. Lavan, O. and Levy, R. (2010), "Performance based optimal seismic retrofitting of yielding plane frames using added viscous damping", Earthq. Struct., 1(3), 307-326. https://doi.org/10.12989/eas.2010.1.3.307
  17. Li, B. and Liang, X.W. (2007), "Design of supplemental viscous dampers in inelastic SDOF system based on improved capacity spectrum method", Struct. Eng. Mech., 27(5), 541-554. https://doi.org/10.12989/sem.2007.27.5.541
  18. Lin, Y.Y., Chang, K.C. and Chen, C.Y. (2008), "Direct displacement-based design for seismic retrofit of existing buildings using nonlinear viscous dampers", Bull. Earthq. Eng., 6(3), 535-552. https://doi.org/10.1007/s10518-008-9062-9
  19. NEHRP 2000 Proposal 12-7 and Chapter 15 (2000), Structures with Damping Systems, The National Earthquake Hazards Reduction Program, Washington, D. C.
  20. PRC Profession Standard (2011), Technical Specification for Building with Energy Dissipation Devices (Questionnaire Opinion Manuscript), The Ministry of Housing and Urban-Rural Construction of the People's Republic of China, Beijing, China.
  21. PRC National Standard (2010), Code for Seismic Design of Buildings (GB 50011-2010), The Ministry of Housing and Urban-Rural Construction of the People's Republic of China, China Architecture & Building Press, Beijing, China.
  22. PRC National Standard (2008), Standard for Classification of Seismic Protection of Building Construction (GB 50223-2008), The Ministry of Housing and Urban-Rural Construction of the People's Republic of China, China Architecture & Building Press, Beijing, China.
  23. Silvestri, S., Gasparini, G. and Trombetti, T. (2011), "Seismic design of a precast r.c. structure equipped with viscous dampers", Earthq. Struct., 2(3), 297-321. https://doi.org/10.12989/eas.2011.2.3.297
  24. Soong, T.T. and Dargush, G.F. (1997), Passive Energy Dissipation Systems in Structural Engineering, John Wiley and Sons, Ltd., New York.
  25. Sorace, S. and Terenzi, G. (2008), "Seismic protection of frame structures by fluid viscous damped braces", J. Struct. Eng., Am. Soc. Civil Eng., 134(1), 45-55.
  26. Symans, M.D. and Constantinou, M.C. (1998), "Passive fluid viscous damping systems for seismic energy dissipation", J. Earthq. Technol., Special Issue on Passive Control of Struct., 35(4), 185-206.
  27. Taylor, T.P. (2010), "Smart buildings and viscous dampers - a design engineer's perspective", Struct. Des. Tall Spec. Build., 19(4), 369-372. https://doi.org/10.1002/tal.621
  28. Tsai, C.X., Chen, K.C., Lin, S.B. and Ho, C.L. (2000), "Analytic model of fluid viscous damper under seismic loadings", J. Press. Vess-T. ASME, 402, 175-178.
  29. Uang, C.M. and Bertero, V.V. (1988), Use of Energy as a Design Criterion in Earthquake-Resistant Design, Report No. UCB/EERC-88/18, University of California, Berkeley
  30. Weng, D.G., He, H., Lu, X.L., Ding, J.M. and Wang, H.Q. (2009), "Structural analysis of the Shanghai World Expo 2010 Theme Hall with viscous damper bracings", China Civ. Eng. J., 42(12), 118-127.
  31. Weng, D.G. and Lu, X.L. (2004), "Study on design parameters of energy dissipation structures with experiment verification", J. Earthq. Eng. Eng. Vib., 24(2), 150-157.
  32. Weng, D.G., Zhang, C., Xia, J.D., Lu, X.L. and Zhang, S.M. (2012), "Experimental and numerical study on RC frame joint strengthened with enveloped steel plates", Proceeding of the 15th World Conference on Earthquake Engineering, Lisbon, Portugal, September.
  33. Weng, D.G., Zhang, C. and Lu, X.L. (2011), "Application of energy dissipation technology to C-category frame structure of school buildings for seismic retrofit of increasing precautionary intensity", Adv. Mater. Res., 163-167, 3480-3487.
  34. Weng, D.G., Zhang, R.F., Zhang, S.M. and Lu, X.L. (2009), "Application of energy dissipation method based on seismic performance and demand for post-earthquake R.C. frame retrofit", Proceedings of the 11th World Conference on Seismic Isolation, Energy Dissipation and Active Vibration Control of tructures, Guangzhou, China, November.
  35. Zeng, S. (2009), Application of Energy Dissipation Technology to Seismic Retrofit of Multi-storey RC Frame Damaged in Earthquake, Master Thesis, Tongji University, Shanghai.

피인용 문헌

  1. Passive energy dissipation-based retrofit strategies for R/C frame water towers vol.106, 2016, https://doi.org/10.1016/j.engstruct.2015.10.038
  2. Seismic assessment and retrofit of two heritage-listed R/C elevated water storage tanks vol.77, 2015, https://doi.org/10.1016/j.soildyn.2015.05.007
  3. A methodology for design of metallic dampers in retrofit of earthquake-damaged frame vol.56, pp.4, 2015, https://doi.org/10.12989/sem.2015.56.4.569
  4. Structural safety redundancy-based design method for structure with viscous dampers vol.59, pp.5, 2016, https://doi.org/10.12989/sem.2016.59.5.821
  5. Analysis and mitigation of seismic pounding of a slender R/C bell tower vol.71, 2014, https://doi.org/10.1016/j.engstruct.2014.04.006
  6. Applicability of a Simplified SDOF Method in Longitudinal Deck-Pier Poundings of Simply Supported Girder Bridges vol.2016, 2016, https://doi.org/10.1155/2016/3569674
  7. Existing prefab R/C industrial buildings: Seismic assessment and supplemental damping-based retrofit vol.94, 2017, https://doi.org/10.1016/j.soildyn.2017.01.023
  8. Motion control-based seismic retrofit solutions for a R/C school building designed with earlier Technical Standards vol.12, pp.6, 2014, https://doi.org/10.1007/s10518-014-9616-y
  9. Probabilistic Seismic Response Models for Risk Assessment and Design of Steel Moment Frames with Linear Viscous Dampers vol.35, pp.1, 2019, https://doi.org/10.1193/031117EQS046M
  10. A “direct five-step procedure” for the preliminary seismic design of buildings with added viscous dampers vol.173, pp.None, 2018, https://doi.org/10.1016/j.engstruct.2018.06.103
  11. Innovative Structural Solutions for Prefab Reinforced Concrete Hall-Type Buildings vol.13, pp.1, 2012, https://doi.org/10.2174/18748368019130149
  12. Application of a Comprehensive Seismic Retrofit Procedure for Steel Buildings Using Nonlinear Viscous Dampers vol.17, pp.8, 2012, https://doi.org/10.1007/s40999-018-0384-y
  13. Advanced Seismic Retrofit of a Mixed R/C-Steel Structure vol.9, pp.12, 2012, https://doi.org/10.3390/buildings9120241
  14. A New Method to Calculate Additional Damping Ratio considering the Effect of Excitation Frequency vol.2020, pp.None, 2012, https://doi.org/10.1155/2020/3172982
  15. Seismic behavior of structural and non-structural elements in RC building with bypass viscous dampers vol.34, pp.4, 2012, https://doi.org/10.12989/scs.2020.34.4.487
  16. Probabilistic seismic and fire assessment of an existing reinforced concrete building and retrofit design vol.74, pp.4, 2012, https://doi.org/10.12989/sem.2020.74.4.481
  17. Calculation method of time-variant additional damping ratio and bi-objective design of RC frame with BRBs vol.33, pp.None, 2021, https://doi.org/10.1016/j.istruc.2021.06.025