References
- Andriono, T. and Carr, A.J. (1991), "A simplified earthquake resistant design method for base-isolated multistory structures", Bull. NZ. Natl. Soc. Earthq. Eng., 24(3), 238-250.
- Andriono, T. and Carr, A.J. (1991), "Reduction and distribution of lateral seismic inertia forces on base-isolated multistory structures", Bull. NZ. Natl. Soc. Earthq. Eng., 24(3), 225-237.
- Cardone, D., Dolce, M. and Gesualdi, G. (2009), "Lateral force distributions for the linear static analysis of baseisolated buildings", Bull. Earthq. Eng., 7(3), 801-834. https://doi.org/10.1007/s10518-009-9104-y
- Celebi, M. (1996), "Successful performance of a base-isolated hospital building during the 17 January 1994 Northridge earthquake", Struct. Design Tall Build., 5(2), 95-109. https://doi.org/10.1002/(SICI)1099-1794(199606)5:2<95::AID-TAL71>3.0.CO;2-7
- Chopra, A.K. (2005), Dynamics of Structures Theory and Applications to Earthquake Engineering, Prentice Hall, NJ.
- Deb, S.K., Paul, D.K. and Thakkar, S.K. (1997), "Simplified non-linear dynamic analysis of base isolated buildings subjected to general plane motion", Eng. Comput., 14(5), 542-557. https://doi.org/10.1108/02644409710170384
- Jangid, R.S. (2002), "Parametric study of base isolated structures", Adv. Struct. Eng., 5(2), 113-122, Multiscience Publishing Co. Ltd., London, UK. https://doi.org/10.1260/1369433021502605
- Jangid, R.S. (2007), "Optimum lead-rubber isolation bearings for near-fault motions", Eng. Struct., 29(10), 2503- 2513. https://doi.org/10.1016/j.engstruct.2006.12.010
- Jangid, R.S. and Kelly, J.M. (2001), "Base isolation for near-fault motions", Earthq. Eng. Struct. Dyn., 30(5), 691-707. https://doi.org/10.1002/eqe.31
- Lee, D.G., Hong, J.M. and Kim, J. (2001), "Vertical distribuition of equivalent static loads for base isolated building structures", Eng. Struct., 23(10), 1293-1306. https://doi.org/10.1016/S0141-0296(01)00031-1
- Makris, N. and Chang, S.P. (2000), "Effect of viscous, viscoplastic, and friction damping on the response of seismic isolated structures", Earthq. Eng. Struct. D., 29(1), 85-107. https://doi.org/10.1002/(SICI)1096-9845(200001)29:1<85::AID-EQE902>3.0.CO;2-N
- Matsagar, V.H. and Jangid, R.S. (2004), "Influence of isolator characteristics on the response of base-isolated structures", Eng. Struct., 26(12), 1735-1749. https://doi.org/10.1016/j.engstruct.2004.06.011
- Mokha, A., Constantinou, M.C. and Reinhorn, A.M. (1988), Teflon Bearings in Aseismic Base Isolation: Experimental Studies and Mathematical Modeling, Technical Report NCEER-88-0038, State University of New York, Buffalo, NY.
- Moussa, L. (2009), Base Isolated Buildings: Parametric Dynamic Analysis and Computer Simulations, Ph.D. Thesis, Technical University of Civil Engineering, Bucharest, Romania.
- Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures: From Theory to Practice, John Wiley and Sons, Inc., NY.
- Nagarajaiah, S., Reinhorn, A.M. and Constantinou, M.C. (1991), "Nonlinear dynamic analysis of 3D-base isolated structures", J. Struct. Eng., 117(7), 2035-2054. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:7(2035)
- Nagarajaiah, S., Reinhorn, A.M. and Constantinou, M.C. (1993), "Torsion in base isolated structures with elastomeric isolation systems", J. Struct. Eng., 119(10), 2932-2951. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:10(2932)
- Narasimhan, S., Nagarajaiah, S., Johnson, A. and Gavin, H.P. (2003), "Smart base isolated building benchmark problem", Proceedings of 16th ASCE Engineering Mechanics Conference, University of Washington, Seattle.
- Newmark, N.M. and Hall, W.J. (1982), Earthquake Spectrum and Design, Monograph Series, Earthquake Engineering Research Institute, Oakland.
- Park, Y.J., Wen, Y.K. and Ang, A.H.S. (1986), "Random vibration of hysteretic systems under bi-directional ground motions", Earthq. Eng. Struct. D., 14(4), 543-557. https://doi.org/10.1002/eqe.4290140405
- Reinhorn, A.M., Nagarajaiah, S., Constrantinou, M.C., Tsopelas, P. and Li, R. (1994), 3D-BASIS: Version 2.0 Computer Program for Nonlinear Dynamics Analysis of Three Dimensional Base Isolated Structures, Technical Report NCEER-95-0018, State University of New York, Buffalo, NY.
- Ribakov, Y. (2010), "Reduction of structural response to near fault earthquakes by seismic isolation columns and variable friction dampers", Earthq. Eng. Eng. Vib., 9(1), 113-122. https://doi.org/10.1007/s11803-010-9059-7
- Ryan, K.L. and Chopra, A.K. (2004), "Estimation of seismic demands on isolators in asymmetric buildings using non-linear analysis", Earthq. Eng. Struct D., 33(3), 395-418. https://doi.org/10.1002/eqe.358
- Ryan, K.L. and Chopra, A.K. (2005), Estimating The Response of Base Isolated Buildings Including Torsion, Rocking and Axial Load Effects, Report No. UCB/EERC 2005-01, Earthquake Engineering Research Center, Berkeley, CA.
- Ryan, K.L. and Chopra, A.K. (2006), "Estimating seismic demands for isolation bearings with building overturning effects", J. Struct. Eng. ASCE, 132(7), 1118-1128. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:7(1118)
- Seguin, C.E., De la Llera, J.C. and Almazan, J.L. (2008), "Base structure interaction of linearly isolated structures with lateral torsional coupling", Eng. Struct., 30(1), 110-125. https://doi.org/10.1016/j.engstruct.2007.02.019
- Stanton, J.F. and Roeder, C.W. (1991). "Advantages and Limitations of Seismic Isolation", EERI Spectra, 7(2), 301-309. https://doi.org/10.1193/1.1585630
- Tena-Colunga, A. (2002), "Seismic design of base-isolated structures using constant strength spectra", J. Earthq. Eng., 6(4), 553-585.
- Tsai, C.S., Chen, B.J. and Chiang, T.C. (2003), "Experimental and computational verification of reasonable design formulae for base-isolated structures", Earthq. Eng. Struct. D., 32(9), 1389-1406. https://doi.org/10.1002/eqe.279
- Tsai, C.S., Chen, W.S., Chen, B.J. and Pong, W.S. (2006), "Vertical distributions of lateral forces on base isolated structures considering higher mode effects", Struct. Eng. Mech., 23(5), 543-562. https://doi.org/10.12989/sem.2006.23.5.543
- Wen, Y.K. (1976), "Method of random vibration of hysteretic systems", J. Eng. Mech. Div., 102(2), 249-263.
- York, K. and Ryan, K.L. (2008), "Distribution of lateral forces in base-isolated buildings considering isolation system nonlinearity", J. Earthq. Eng., 12(7), 1185-1204. https://doi.org/10.1080/13632460802003751
- Zayas, V.A., Low, S.S., Bozzo, L.M. and Mahin, S.A. (1989), Feasibility and Performance Studies on Improving The Earthquake Resistance of New and Existing Buildings Using The Friction Pendulum System, Report No. UCB/EERC-89/09, Earthquake Engineering Research Center, Berkeley, CA.
Cited by
- A direct method for determining floor response spectra at the ITER Tokamak Complex vol.323, 2017, https://doi.org/10.1016/j.nucengdes.2017.01.030
- Simplified procedure for seismic analysis of base-isolated structures vol.8, pp.5, 2015, https://doi.org/10.12989/eas.2015.8.5.1091
- State-of-the-art review: Reduction factor of traditional steel moment resisting, braced or eccentrically braced systems vol.35, pp.None, 2012, https://doi.org/10.1016/j.istruc.2021.11.028