참고문헌
- American Concrete Institute (ACI) (2008), Building Code Requirements for Structural Concrete and Commentary, ACI 318-08 and ACI 318M-08, Farmington Hills, MI.
- Angelakos, D., Bentz, E.C. and Collins, M.P. (2001), "Effect of concrete strength and minimum stirrup on shear strength of large members", ACI Struct. J., 98(3), 290-300.
- ASTM International (2007), Standard Specification for Headed Steel Bars for Concrete Reinforcement, ASTM A970-07, West Conshohocken, PA.
- Bentz, E.C. and Collins, M.P. (2000), RESPONSE 2000, Version 1.05, University of Toronto, Ontario.
- Canadian Standards Association (CSA) (2004), Design of Concrete Structures, CSA A23.3-04, Mississauga, Ontario.
- Collins, M.P. and Kuchma, D. (1999), "How safe are our large, lightly reinforced concrete beams, slabs, and footings?" ACI Struct. J., 96(4), 482-490.
- Collins, M.P. and Mitchell, D. (1991), Prestressed Concrete Structures, Prentice-Hall, Englewood Cliffs, NJ.
- Collins, M.P., Mitchell, D. and MacGregor, J.G. (1993), "Structural design consideration for high-strength concrete", Concrete Int., 15(5), 27-34.
- European Standard (2003), Eurocode 2: Design of Concrete Structures - Part 1: General Rules and Rules for Buildings, prEN 1992-1-1, Final draft, European Committee for Standardization, Brussels.
- Gardner, N.J. (2005), ACI 318-05, CSA A23.3-04, Eurocode 2 (2003), DIN 1045-1 (2001), BS 8110-97 and CEB-FIP MC 90 provisions for punching shear of reinforced concrete flat slabs. Punching Shear in Reinforced Concrete Slabs", SP-232 (Ed. Polak MA), American Concrete Institute, Farmington Hills, MI.
- Gayed, R.B. and Ghali, A. (2004), "Double-head studs as shear reinforcement in concrete I-beams", ACI Struct. J., 101(4), 549-557.
- Ghali, A. and Dilger, W. (1998), "Anchoring with double-head studs", Concrete Int., 20(11), 21-24.
- Ghali, A. and Youakim, S.A. (2005), "Headed studs in concrete: state of the art", ACI Struct. J., 102(5), 657-667.
- Griezic, A., Cook, W.D. and Mitchell, D. (1994), "Tests to determine performance of deformed welded wire fabric stirrups", ACI Struct. J., 91(2), 211-220.
- Johnson, M.K. and Ramirez, J.A. (1989), "Minimum shear reinforcement in beams with higher strength concrete", ACI Struct. J., 86(4), 376-382.
- Joint ACI-ASCE Committee 445 (1998), "Recent approaches to shear design of structural concrete", J. Struct. Eng., 124(12), 1375-1417. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:12(1375)
- Mast, R.F., Dawood, M., Rizkalla, S.H. and Zia, P. (2008), "Flexural strength design of concrete beams reinforced with high-strength steel bars", ACI Struct. J., 105(4), 570-577.
- Roller, J.J. and Russel, H.G. (1990), "Shear strength of high-strength concrete beams with web reinforcement", ACI Struct. J., 87(2), 191-198.
- Sumpter, M.S., Rizkalla, S.H. and Zia, P. (2009), "Behavior of high-performance steel as shear reinforcement for concrete beams", ACI Struct. J., 106(2), 171-177.
- Tompos, E.J. and Frosch, R.J. (2002), "Influence of beam size, longitudinal reinforcement, and stirrup effectiveness on concrete shear strength", ACI Struct. J., 99(5), 559-567.
- Yang, J.M., Yoon, Y.S., Cook, W.D. and Mitchell, D. (2010), "Punching shear behavior of two-way slabs reinforced with high-strength steel", ACI Struct. J., 107(4), 468-475.
- Yoon, Y.S., Cook, W.D. and Mitchell, D. (1996), "Minimum shear reinforcement in normal, medium, and highstrength concrete beams", ACI Struct. J., 93(5), 576-584.
피인용 문헌
- Bond behaviour of straight, hooked, U-shaped and headed bars in cracked concrete vol.17, pp.5, 2016, https://doi.org/10.1002/suco.201500199
- FE modeling of inelastic behavior of reinforced high-strength concrete continuous beams vol.49, pp.3, 2014, https://doi.org/10.12989/sem.2014.49.3.373