DOI QR코드

DOI QR Code

Determination of limiting temperatures for H-section and hollow section columns

  • Kwon, In-Kyu (Department of Fire Protection Engineering, Kangwon National University) ;
  • Kwon, Young-Bong (Department of Civil Engineering, Yeungnam University)
  • 투고 : 2011.12.02
  • 심사 : 2012.06.14
  • 발행 : 2012.10.25

초록

The risk of progressive collapse in steel framed buildings under fire conditions is gradually rising due to the increasing use of combustible materials. The fire resistance of such steel framed buildings is evaluated by fire tests. Recently, the application of performance based fire engineering makes it easier to evaluate the fire resistance owing to various engineering techniques and fire science. The fire resistance of steel structural members can be evaluated by the comparison of the limiting temperatures and maximum temperatures of structural steel members. The limiting temperature is derived at the moment that the failure of structural member results from the rise in temperature and the maximum temperature is calculated by using a heat transfer analysis. To obtain the limiting temperatures for structural steel of grades SS400 and SM490 in Korea, tensile strength tests of coupons at high temperature were conducted. The limiting temperatures obtained by the tensile coupon tests were compared with the limiting temperatures reported in the literature and the results of column fire tests under four types of loading with different load ratios. Simple limiting temperature formulas for SS400 and SM490 steel based on the fire tests of the tensile coupons are proposed. The limiting temperature predictions using the proposed formulas were proven to be conservative in comparison with those obtained from H-section and hollow section column fire tests.

키워드

참고문헌

  1. Architectural Institute of Japan (AIJ) (1999), "Recommendations for Fire Resistance Design of Steel Structures".
  2. American Institute of Steel Construction (AISC) (2005), "Specification for Structural Steel Buildings", Chicago, Il, USA.
  3. Bwalya, A. (2008), "An overview of design fires for building compartments", Fire Technology, 44(2), 167-184. https://doi.org/10.1007/s10694-007-0031-7
  4. BSI, BS 5950: Part8 (1990), "Structural Use of Steelwork in Buildings".
  5. Buchanan, A. H. (1994), "Fire Engineering Design Guide".
  6. CEN, Eurocode 3 (1995), "Design of Steel Structures Part 1.2: General Rules Structural fire design".
  7. DETR (2000), "The Building Regulations 1991, Fire Safety, Approved Document B".
  8. ISO TC92/SC4, WG12 (2009), "Structures in fire".
  9. Korean Ministry of Construction and Transportation (2005). "Korean Building Codes".
  10. Korean Ministry of Construction and Transportation (2002), "Development of Fire Engineering Technique".
  11. Korean Standard Association, KS D 0026 (2002), "Method of elevated temperature tensile test for steels and heat-resisting alloys".
  12. Korean Standard Association, KS B 0802 (2003), "Method of tensile test for metallic materials".
  13. Korean Standard Association, KS F 2257-1 (2005), "Methods of fire resistance test for elements of building construction-general requirements".
  14. Korean Standard Association, KS F 2257-7 (2005), "Methods of fire resistance test for elements of building construction-beam, column".
  15. Kwon, I.K. (2009), "Development of Analytic Program for Calculation of Fire Resistant Performance on Steel Structures", Journal of Korean architectural institute, 21, 201-208.
  16. Outinen, J. and Makelainen, P. (2004), "Mechanical properties of structural steel at elevated temperature and cooling down", Fire and Materials, 28(2-4), 237-251. https://doi.org/10.1002/fam.849
  17. Park, S.Y., Park, W.S. Kim, H.Y. and Hong, G.P. (2010), "Study on the Analytical Method for Fire Resistance Calculation of Asymmetric Slim floor Beam", J. of Korean Institute of Fire Sci. & Eng., 24, 31-37.
  18. Research Industry of Science & Technology (2004), "Development of fire engineering technique of structural steels (III)".
  19. Richard Liew, J.Y. and Ma, K.Y. (2004), "Advanced analysis of 3D steelwork exposed to compartment fire", Fire and Materials, 28(2-4), 253-267. https://doi.org/10.1002/fam.850
  20. Saab, H.A. and Nethercot, D.A. (1991), "Modelling steel frame behavior under fire conditions", J. Eng. Struct., 13(4), 371-382. https://doi.org/10.1016/0141-0296(91)90024-7
  21. SBI (1976), "Fire Engineering Design of Steel Structures".
  22. Standards New Zealand, NZS3404: Part1:1997 (1998), "Steel Structures Standard".
  23. Usmani, A., Roben, C. and Al-Remal, A. (2009), "A Very Simple Method for Assessing Tall Building Safety in Major Fires", Journal of Steel Structures, 9(1), 17-28. https://doi.org/10.1007/BF03249476
  24. Wang, Y.C., Lennon, T. and Moore, D.B. (1995), "The behavior of steel frame subject to fire", Journal of Constructional Steel Research, 35, 291-322. https://doi.org/10.1016/0143-974X(94)00046-K
  25. Wong, M.B. (2005), "Modelling of axial restraints for limiting temperature calculation of steel members in fire", Journal of Construction Steel Research, 61(5), 675-687. https://doi.org/10.1016/j.jcsr.2004.10.003
  26. Wong, M.B. (2006), "Effect of Torsion on Limiting Temperature of Steel Structures in Fire", J. Struct. Eng., 132(5), 726-732. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:5(726)
  27. Zalok, E., Hadjisophocleous, G.V. and Mehaffey, J.R. (2009), "Fire loads in commercial premies", Fire and Materials, 33, 63-78. https://doi.org/10.1002/fam.984

피인용 문헌

  1. Structural stability of fire-resistant steel (FR490) H-section columns at elevated temperatures vol.17, pp.1, 2014, https://doi.org/10.12989/scs.2014.17.1.105
  2. Simplified robustness assessment of steel framed structures under fire-induced column failure vol.35, pp.2, 2012, https://doi.org/10.12989/scs.2020.35.2.199