DOI QR코드

DOI QR Code

Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders

  • Prakash, Amar (CSIR-Structural Engineering Research Centre, CSIR Campus) ;
  • Anandavalli, N. (CSIR-Structural Engineering Research Centre, CSIR Campus) ;
  • Madheswaran, C.K. (CSIR-Structural Engineering Research Centre, CSIR Campus) ;
  • Lakshmanan, N. (CSIR-Structural Engineering Research Centre, CSIR Campus)
  • Received : 2010.12.29
  • Accepted : 2012.05.29
  • Published : 2012.09.25

Abstract

In this paper, experimental investigations on high strength steel (HSS) stud connected steel-concrete composite (SCC) girders to understand the effect of shear connector density on their flexural behaviour is presented. SCC girder specimens were designed for three different shear capacities (100%, 85%, and 70%), by varying the number of stud connectors in the shear span. Three SCC girder specimens were tested under monotonic/quasi-static loading, while three similar girder specimens were subjected to non-reversal cyclic loading under simply supported end conditions. Details of casting the specimens, experimental set-up, and method of testing, instrumentation for the measurement of deflection, interface-slip and strain are discussed. It is found that SCC girder specimen designed for full shear capacity exhibits interface slip for loads beyond 25% of the ultimate load capacity. Specimens with lesser degree of shear connection show lower values of load at initiation of slip. Very good ductility is exhibited by all the HSS stud connected SCC girder specimens. It is observed that the ultimate moment of resistance as well as ductility gets reduced for HSS stud connected SCC girder with reduction in stud shear connector density. Efficiency factor indicating the effectiveness of high strength stud connectors in resisting interface forces is estimated to be 0.8 from the analysis. Failure mode is primarily flexure with fracturing of stud connectors and characterised by flexural cracking and crushing of concrete at top in the pure bending region. Local buckling in the top flange of steel beam was also observed at the loads near to failure, which is influenced by spacing of studs and top flange thickness of rolled steel section. One of the recommendations is that the ultimate load capacity can be limited to 1.5 times the plastic moment capacity of the section such that the post peak load reduction is kept within limits. Load-deflection behaviour for monotonic tests compared well with the envelope of load-deflection curves for cyclic tests. It is concluded from the experimental investigations that use of HSS studs will reduce their numbers for given loading, which is advantageous in case of long spans. Buckling of top flange of rolled section is observed at failure stage. Provision of lips in the top flange is suggested to avoid this buckling. This is possible in case of longer spans, where normally built-up sections are used.

Keywords

References

  1. AWS. (2006), American welding society, Structural welding code.
  2. Bouazaoui, L. Perrenot, G., Delmas, Y. and Li, A. (2007), "Experimental study of bonded steel concrete composite structures", J. Constr. Steel Res., 63(9), 1268-1278. https://doi.org/10.1016/j.jcsr.2006.11.002
  3. CEB. (1996), RC elements under cyclic loading, state of the art report, Comite Euro-International DU Beton, Thomas Telford, 1996.
  4. Chapman, J.C. and Balakrishnan, S. (1964), "Experiments on composite beams", Struct. Eng., 42(11), 369-383.
  5. DD ENV 1994-1-1, Eurocode 4, Design of composite steel and concrete structures- Part 1.1: General rules and rules for building, London: British Standards Institution.
  6. IRC: 22-1986, "Standard specification and code of practice for road bridges, section VI, (Composite Construction)", The Indian road congress, New Delhi.
  7. IRC: 24-2000, "Standard specification and code of practice for road bridges, (Composite Construction)", The Indian road congress, New Delhi.
  8. IS 10262-1982. IS recommended guidelines for mix design. Bureau of Indian Standards.
  9. Jasim, N.A. (1999), "Deflections of partially composite beams with linear connector density", J. Constr. Steel Res., 49(3), 241-254. https://doi.org/10.1016/S0143-974X(98)00206-5
  10. Johnson, R.P. and Oehlers, D.J. (1981), "Analysis and design for longitudinal shear in composite T-beams", Proceedings of Institution of Engineers, London, Part 2, vol. 71, December, 989-1021.
  11. Jurkiewiez, B. and Hottier, J.M. (2005), "Static behaviour of a steel-concrete composite beam with an innovative horizontal connection", J. Constr. Steel Res., 61(9), 1286-1300. https://doi.org/10.1016/j.jcsr.2005.01.008
  12. Jurkiewiez, B. (2009), "Static and cyclic behaviour shear connections", J. Constr. Steel Res., 65(12), 2207-2216. https://doi.org/10.1016/j.jcsr.2009.06.018
  13. Jurkiewiez, B. and Braymand, S. (2007), "Experimental study of a pre-cracked steel-concrete composite beam", J. Constr. Steel Res., 63(1), 135-144. https://doi.org/10.1016/j.jcsr.2006.03.013
  14. Lam, D. and El-Lobody, E. (2005), "Behaviour of headed stud shear connectors in composite beam", Journal of Struct. Eng., 131(1), 96-107. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:1(96)
  15. Liang, Q.Q., Uy, B., Bradford, M.A. and Ronagh, H.R. (2004), "Ultimate strength of continuous composite beams in combined bending and shear", 60(8), 1109-1128. https://doi.org/10.1016/j.jcsr.2003.12.001
  16. Madheswaran, C.K., Natarajan, K. and Prakash, A. (2007), "Strength of shear connectors in steel concrete composite beams", Journal of Institution of Engineers (India), 88(8), pp 14-20.
  17. Mirza, O. and Uy, B. (2009), "Effects of steel fibre reinforcement on the behaviour of headed stud shear connectors for composite steel-concrete beams", Advanced Steel Construction, 5(1), 72-95.
  18. Nie, J. and Cai, C.S. (2003), "Steel-Concrete Composite Beams Considering Shear Slip Effects" J. Struct. Eng., 129(4), 495-506. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:4(495)
  19. Nie, J., Cai, C.S., Wu, H. and Fan, J.S. (2006), "Experimental and theoretical study of steel-concrete composite beams with openings in concrete flange", Eng. Struct., 28(7), 992-1000. https://doi.org/10.1016/j.engstruct.2005.11.004
  20. Nie, J., Xiao, Y., Tan, Y. and Wang, H. (2004), "Experimental Studies on Behaviour of Composite Steel High Strength Concrete Beams", ACI Structural Journal, 101(2), 245-251.
  21. Oehlers, D.J. and Coughlan, C.G. (1986), "The shear stiffness of stud shear connections in composite beams", J. Constr. Steel Res., 6(4), 273-284. https://doi.org/10.1016/0143-974X(86)90008-8
  22. Oehlers, D.J. and Johnson, R.P. (1987),"The strength of stud shear connections in composite beams", Structural, 65B(2), 44-48.
  23. Oehlers, D.J. and Bradford, M.A. (1995), Composite steel and concrete structural members: Fundamental Behaviour, first edition, Pergamon Press, Oxford.
  24. Oehlers, D.J., Nguyen, N.T., Ahmed, M. and Bradford, M.A. (1997), "Partial Interaction in Composite Steel and Concrete Beams with Full Shear Connection", J. Constr. Steel Res., 41(2-3), 235-248. https://doi.org/10.1016/S0143-974X(97)80892-9
  25. Oven, V.A., Burgess, I.W., Plank, R.J. and Abdul, W.A.A. (1997), "An analytical model for the analysis of composite beam with partial interaction", Comput. Struct., 62(3), 493-504. https://doi.org/10.1016/S0045-7949(97)80001-2
  26. Shim, C.S., Lee, P.G. and Yoon, T.Y. (2004), "Static Behaviour of large shear stud connectors", Eng. Struct., 26(12), 1853-1860. https://doi.org/10.1016/j.engstruct.2004.07.011
  27. Slutter, R.G. and Driscoll, G.C. (1965), "Flexural strength of steel-concrete composite beam", Journal of Structural Division, ASCE, 91(ST2), 71-99.
  28. Uy, B. and Bradford, M.A. (1996), "Elastic local buckling of steel plates in composite steel-concrete members", Eng. Struct., 18(3), 193-200. https://doi.org/10.1016/0141-0296(95)00143-3
  29. Zhao, G. and Li, A. (2008), "Numerical study of a bonded steel and concrete composite beam", Comput. Struct., 86(19-20), 1830-1838. https://doi.org/10.1016/j.compstruc.2008.04.002

Cited by

  1. Behavior of Hybrid Double Skin Concrete Filled Circular Steel Tube Columns vol.14, pp.2, 2013, https://doi.org/10.12989/scs.2013.14.2.191
  2. Shear resistance of stud connectors in high strength concrete vol.52, pp.4, 2014, https://doi.org/10.12989/sem.2014.52.4.647
  3. Behavior of headed shear stud connectors subjected to cyclic loading vol.25, pp.6, 2012, https://doi.org/10.12989/scs.2017.25.6.705