References
- ArcelorMittal Commercial Sections (2008), "Slim Floor, an innovative concept for floors", Long Carbon Europe Sections and Merchant Bars, Esch-sur-Alzette, Luxembourg
- Bailey, C. G. (2003) "Large scale test on a composite Slim Floor system", Steel Compos Struct, 3(3), 153-168. https://doi.org/10.12989/scs.2003.3.3.153
- Dong, Y. (2009) "Behaviour of full-scale frames with Slim Floor slab construction under exposure in a fire resistance furnace", J Fire Prot Eng, 19(3), 197-220. https://doi.org/10.1177/1042391509104183
- Ellobody, E. (2011) "Nonlinear behaviour of unprotected composite Slim Floor steel beams exposed to different fire conditions", Thin Wall Struct, 49(6), 762-771. https://doi.org/10.1016/j.tws.2011.02.002
- EN 1992-1-2 (2005) "Eurocode 2-Design of concrete structures. Part 1-2. General rules - Structural Fire Design", CEN, Brussels.
- EN 1993-1-2 (2005) "Eurocode 3-Design of steel structures. Part 1-2. General rules - Structural Fire Design", CEN, Brussels.
- Fontana, M., Borgogno, W. (1996) "Slim Floor slabs: fire resistance and system behaviour of hollow core slabs on flexible beams", Composite Construction in Steel and Concrete, Proceedings of Engineering Foundation Conference, ASCE, Irsee, Germany.
- Franssen, J. M. (2005) "SAFIR. A Thermal/Structural Program Modelling Structures under Fire", Eng J Aisc, 42(3), 143-158.
- Kim, H. J., Kim, H. Y., Park, S. Y. (2011) "An experimental study on fire resistance of Slim Floor beam", Appl Mech Mater, 82, 752-757. https://doi.org/10.4028/www.scientific.net/AMM.82.752
- Ma, Z., Makelainen, P. (2006) "Structural behaviour of composite Slim Floor frames in fire conditions", J Constr Steel Res, 62(12), 1282-1289. https://doi.org/10.1016/j.jcsr.2006.04.026
- Newman, G. M. (1995) "Fire resistance of Slim Floor beams", J Constr Steel Res, 33(1-2), 87-100. https://doi.org/10.1016/0143-974X(94)00016-B
- Park, S., Kim, H., Kim, H., Hong, K. (2011) "Fire resistance of the Korean asymmetric Slim Floor beam depending on load ratio", J Asian Archit Build, 10(2), 413-420. https://doi.org/10.3130/jaabe.10.413
- PROFILARBED (1995), "RPS Report No 24/95 : Test au feu sur un Plancher type Slim Floor, EMPA/ETH Zurich le 6 aout 1994", Groupe Arcelor, Centre de Recherches, RPS Department, Esch-sur-Alzette, Luxembourg.
- Simoes da Silva, Santiago, A., Vila Real, P., Moore, D. (2005), "Behaviour of steel joints under fire loading", Steel Compos Struct, 5(6), 485-513. https://doi.org/10.12989/scs.2005.5.6.485
- STC - Swinden Technology Centre (1999), 'The behaviour of Multi-storey steel framed buildings in fire - A European joint research programme", British Steel , Rotherham, U.K.
- Wald, F., Simoes da Silva, L., Moore, D., Lennon, T., Chladna, M., Santiago, A., Benes, M., Borges, L. (2005), "Experimental behaviour of steel structure under natural fire", New Steel Construction, 13(3), 24-27.
- Wang, Y. C. (1996), "Tensile membrane action in slabs and its application to the Cardington tests", Second Cardington Conference, BRE, Watford, U.K.
- Zaharia, R., Duma, D., Vassart, O., Gernay, T., Franssen, J. M. "Simplified fire design for Slim Floor beams", Proceedings of the 6th European Conference on Steel and Composite Structures Eurosteel 2011, Budapest, Hungary, Vol. B, 1539-1544.
Cited by
- Fire resistance of DELTABEAM® composite beams: a numerical investigation vol.8, pp.4, 2017, https://doi.org/10.1108/JSFE-05-2016-0003
- 10.08: Application of advanced materials for enhancing the fire performance of slim-floors vol.1, pp.2-3, 2017, https://doi.org/10.1002/cepa.306
- 10.01: Analytical methods for the prediction of fire resistance of “reinforced” slim floor beams vol.1, pp.2-3, 2017, https://doi.org/10.1002/cepa.299
- Moment capacity of cast-iron beams exposed to fire vol.169, pp.10, 2016, https://doi.org/10.1680/jstbu.15.00120
- Fire design of slim‐floor beams vol.88, pp.7, 2012, https://doi.org/10.1002/stab.201900030
- Practical Design Methods for Fire Resistance of Restrained Cellular Steel Beams vol.19, pp.6, 2012, https://doi.org/10.1007/s13296-019-00248-w
- Internally fire protected composite steel-concrete slim-floor beam vol.227, pp.None, 2012, https://doi.org/10.1016/j.engstruct.2020.111447
- Analytical Method for the Bending Resistance of Slim Floor Beams with Asymmetric Double-T Steel Section under ISO Fire vol.12, pp.2, 2012, https://doi.org/10.3390/app12020574