DOI QR코드

DOI QR Code

An enhanced method of predicting effective thickness of corroded steel plates

  • Kaita, Tatsumasa (Department of Civil Engineering & Architecture, Tokuyama College of Technology) ;
  • Appuhamy, J.M. Ruwan S. (Department of Civil & Environmental Engineering, Ehime University) ;
  • Ohga, Mitao (Department of Civil & Environmental Engineering, Ehime University) ;
  • Fujii, Katashi (Department of Social & Environmental Engineering, Hiroshima University)
  • 투고 : 2010.11.09
  • 심사 : 2012.02.27
  • 발행 : 2012.05.25

초록

Many steel bridge infrastructures in the world are getting older, and a large number of these structures are in need of maintenance, rehabilitation or replacement. Most of them are subjected to corrosion due to exposure to aggressive environmental conditions and inadequate maintenance, causing reduction of their carrying capacities. In order to have an adequate bridge management, it is of paramount importance to develop an efficient, accurate and rapid condition assessment method which can be used to make reliable decisions affecting the cost and safety. Therefore, a simple and accurate method of calculating remaining yield and tensile strength by using a concept of representative effective thickness with correlation of initial thickness and maximum corroded depth is proposed in this study, based on the results of many tensile coupon tests of corroded plates obtained from a steel plate girder with severe corrosion, used for about 100 years. Furthermore, a strength reduction diagram which will be very useful for bridge inspection engineers to make rational decisions about the maintenance management of aged steel bridge infrastructures is presented.

키워드

참고문헌

  1. Bruneau, M. and Zahrai, S.M. (1997), "Effect of severe corrosion on cyclic ductility of steel", J. Struct. Eng., 123(11), 1478-1486. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:11(1478)
  2. Chen, M. and Das, S. (2009), "Experimental study on repair of corroded steel beam using CFRP", Steel. Compos. Struct., 9(2), 103-118. https://doi.org/10.12989/scs.2009.9.2.103
  3. Kaita, T., Fuji, K., Miyashita, M., Uenoya, M., Okumura, M. and Nakamura, H. (2005), "A simple estimation method of bending strength for corroded plate girder", Collaboration and Harmonization in Creative Systems, 1, 89-97.
  4. Kariya, A., Tagaya, K., Kaita, T. and Fujii, K. (2003), "Basic study on effective thickness of corroded steel plate and material property", Annual conference of JSCE, 967-968. (In Japanese)
  5. Kariya, A., Tagaya, K., Kaita, T. and Fujii, K. (2005), "Mechanical properties of corroded steel plate under tensile force", Proceedings of the $3^{rd}$ International Structural Engineering and Construction Conference (ISEC-03), Japan, 105-110.
  6. Khedmati, M.R., Nouri, Z.H.M.E. and Roshanali, M.M. (2011), "An effective proposal for strength evaluation of steel plates randomly corroded on both sides under uniaxial compression", Steel. Compos. Struct., 11(3), 183-205. https://doi.org/10.12989/scs.2011.11.3.183
  7. Kitada, T. (2006), "Considerations on recent trends in, and future prospects of, steel bridge construction in Japan", J. Constr. Steel. Res., 62, 1192-1198. https://doi.org/10.1016/j.jcsr.2006.06.016
  8. Matsumoto, M., Shirai, Y., Nakamura, I. and Shiraishi, N. (1989), "A proposal of effective thickness estimation method of corroded steel member", Bridge Foundation Engineering, 23(12), 19-25. (In Japanese)
  9. Muranaka, A., Minata, O. and Fujii, K. (1998), "Estimation of residual strength and surface irregularity of the corroded steel plates", J. Struct. Eng., 44A, 1063-1071. (In Japanese)
  10. Natori, T., Nishikawa, K., Murakoshi, J. and Ohno, T. (2001), "Study on characteristics of corrosion damages in steel bridge members", J. Struct. Mech. and Earthq. Eng., 668(54), 299-311. (In Japanese)
  11. NSBA. (2006), "Corrosion protection of steel bridges", Steel Bridge Design Handbook, Chapter 23, National Steel Bridge Alliance.
  12. Sharifi, Y. and Rahgozar, R. (2010), "Remaining moment capacity of corroded steel beams", Int. J. Steel. Struct., 10(2), 165-176. https://doi.org/10.1007/BF03215828
  13. Sugimoto, I., Kobayashi, Y. and Ichikawa, A. (2006), "Durability evaluation based on buckling characteristics of corroded steel deck girders", QR of RTRI, 47(3), 150-155. https://doi.org/10.2219/rtriqr.47.150
  14. Zahrai, S.M. (2003), "Cyclic strength and ductility of rusted steel members", Asian J. Civil. Eng., 4(2-4), 135-148.

피인용 문헌

  1. Load-carrying capacity degradation of reinforced concrete piers due to corrosion of wrapped steel plates vol.20, pp.1, 2016, https://doi.org/10.12989/scs.2016.20.1.091
  2. Tensile strength prediction of corroded steel plates by using machine learning approach vol.24, pp.5, 2017, https://doi.org/10.12989/scs.2017.24.5.635
  3. Estimation of the properties of corroded steel plates exposed to salt-spray atmosphere vol.54, pp.5, 2012, https://doi.org/10.1080/1478422x.2019.1613779
  4. Compressive behavior of circular hollow and concrete-filled steel tubular stub columns under atmospheric corrosion vol.33, pp.4, 2012, https://doi.org/10.12989/scs.2019.33.4.615
  5. Experimental and numerical investigations on remaining strengths of damaged parabolic steel tubular arches vol.34, pp.1, 2012, https://doi.org/10.12989/scs.2020.34.1.001