DOI QR코드

DOI QR Code

Respiration Monitoring Using an Electromagnetic Interference Shielding PVDF Film-Embedded Elastic Belt

EMI 차폐능을 갖는 PVDF 필름 내장 탄성벨트를 이용한 호흡 모니터링

  • Ahn, Yu Jin (Department of Advanced Materials Engineering for Information & Electronics, College of Engineering, Kyung Hee University) ;
  • Kim, Kap Jin (Department of Advanced Materials Engineering for Information & Electronics, College of Engineering, Kyung Hee University)
  • 안유진 (경희대학교 공과대학 정보.전자 신소재공학과) ;
  • 김갑진 (경희대학교 공과대학 정보.전자 신소재공학과)
  • Received : 2012.10.23
  • Accepted : 2012.12.03
  • Published : 2012.12.31

Abstract

The poled PVDF film sensor with thin silver electrode on both surfaces was coated with conductive carbon paste followed by silicon elastomer/carbon black mixture coating. This process gave it EMI shielding as well as enhanced toughness. The physiological sensing belt(PSB) for respiration monitoring was made by embedding the silicone rubber/carbon black/conductive carbon layer coated PVDF film between elastic textile bands. The sport bra having PSB could be well applied to respiration monitoring for the woman wearing it with very low motion artifact even during walking and running.

Keywords

Acknowledgement

Supported by : 경희대학교, 한국연구재단(NRF), 지식경제부

References

  1. A. M. Sinton and R. Suntheralingam, “Respiratory Inductance Plethysmography with an Electrical Impedance Plethysmograph”, Med Biol Eng Comput, 1988, 26, 213-217. https://doi.org/10.1007/BF02442267
  2. J. I. Kim, H.-J. Park, T.-S. Kim, M.-J. Yun, and J. D. Lee, "Development of Portable Device for Transmitting Respiratory & ECG Gating in List-mode PET Data Acquisition", World Congress on Medical Physics and Biomedical Engineering 2006, IFMBE Proceedings, 2007, 14, pp.874-877.
  3. http://www.vernier.com/files/manuals/rmb.pdf
  4. M. K. Marks, M. South, and B. G. Carter, “Measurement of Respiratory Rate and Timing Using a Nasal Thermocouple”, J Clin Monit, 1995, 11, 159-164. https://doi.org/10.1007/BF01617716
  5. http://www.paramedicine.com/pmc/End_Tidal_CO2.html
  6. Y. M. Chang, J. S. Lee, and K. J. Kim, "Heartbeat Monitoring Technique Based on Corona-poled PVDF Film Sensor for Smart Apparel Application", Solid State Phenom, 2007, 124-126, 299-302. https://doi.org/10.4028/www.scientific.net/SSP.124-126.299
  7. K. J. Kim, S. Yoon, Y. M. Chang, and J. S. Lee, "Application of Uniaxially Stretched PVDF Piezoelectric Film for Medical Diagnosis", Proceedings of the the 9th Asian Textile Conference, p.98, Taichung, Taiwan (R.O.C.), June 28-30, 2007.
  8. Y. M. Chang, S. Yoon, and H. J. Kim, “A Novel Piezoelectric PVDF Film-based Physiological Sensing Belt for a Complementary Respiration and Heartbeat Monitoring System”, Integr Ferroelectr, 2009, 107, 53-68. https://doi.org/10.1080/10584580903324493
  9. K. J. Kim, H. J. Kim, Y. M. Chang, and S. Yoon, "Sensor Comprising a Material Which Generates an Electrical Signal in Response to Elongation", Korean Patent 10-1023446 (2011).
  10. K. J. Kim, S. Yoon, and Y. J. Ahn, "The Method of Manufacturing Piezoelectric Sensor Having Carbon Black", Korean Patent Application 10-2012-0114168(2012).

Cited by

  1. Physical Activity Monitoring Using PVDF Film-Embedded Elastic Belt vol.49, pp.6, 2012, https://doi.org/10.12772/TSE.2012.49.6.418
  2. Uniaxially drawn polylactic acid film based physiological sensor for monitoring sleeping parameters vol.18, pp.10, 2017, https://doi.org/10.1007/s12221-017-7563-3