References
- Tarnawski, V. R., Leong, W. H., Momose, T., and Hamada, Y., 2009, Analysis of ground source heat pumps with horizontal ground heat exchangers for northern Japan, Renewable Energy, Vol. 34, pp. 127-134. https://doi.org/10.1016/j.renene.2008.03.026
- Benli, H. and Durmus, A., 2009, Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating, Energy and Buildings, Vol. 41, pp. 220-228. https://doi.org/10.1016/j.enbuild.2008.09.004
- Esen, H., Inalli, M., Esen, M., and Pihtili, K., 2007, Energy and exergy analysis of a groundcoupled heat pump system with two horizontal ground heat exchangers, Building and Environment, Vol. 42, pp. 3606-3615. https://doi.org/10.1016/j.buildenv.2006.10.014
- Sohn, B. H., Cho, C. S., Shin, H. J., and An, H. J., 2005, Cooling and heating performance evaluation of a GSHP system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 1, pp. 71-81.
- Sohn, B., Choi, J. M., and Choi, H., 2011, Performance simulation of ground-coupled heat pump(GHP) system for a detached house, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 23, No. 6, pp. 392- 399. https://doi.org/10.6110/KJACR.2011.23.6.392
- Lee, C., Park, M., Min, S., Kang, S.-H., Sohn, B., and Choi, H., 2011, Comparison of effective thermal conductivity in closed-loop vertical ground heat exchangers, Applied Thermal Engineering, Vol. 31, pp. 3669-3676. https://doi.org/10.1016/j.applthermaleng.2011.01.016
- Lee, J. Y., Chung, J. T. Woo, J., and Choi, J. M., 2010, Influence of the secondary fluid glow rate of the performance of a GSHP system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, No. 10, pp. 649- 656.
- Kang, S.-H., Choi, J. M., Moon, J., and Kwon, H., 2010, Heating performance of a ground source multi-heat pump for a greenhouse, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, No. 6, pp. 337- 344.
- Sohn, B. and Choi, H., 2011, Thermal diffusivity evaluation of backfilling materials for horizontal ground heat exchanger using singleprobe method, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 23, No. 4, pp. 356-364. https://doi.org/10.6110/KJACR.2011.23.5.356
- IGSHPA, 2009, Ground Source Heat Pump Residential and Light Commercial Design and Installation Guide, Oklahoma State University.
- Sohn, B., 2011, Evaluation of ground temperature and soil thermal diffusivity using the soil temperature data of KMA, Trans. Korea Society of Geothermal Energy Engineers, Vol. 7, No. 1, pp. 1-9.
- Kusuda, T. and Achenbach, P. R., 1965, Earth temperature and thermal diffusivity at selected stations in the United States, ASHRAE Transactions, Vol. 71, pp. 61-75.
- MKE(KNREC), 2010, Guidelines for New and Renewable Energy Systems, Ministry of Knowledge Economy.
- Kline, S. J., 1985, The purpose of uncertainty analysis, J. Fluids Engineering, Vol. 107, pp. 153-160. https://doi.org/10.1115/1.3242449
Cited by
- Prediction of the Heat Exchange Rate for a Horizontal Ground Heat Pump System Using a Ground Heat Transfer Simulation vol.25, pp.6, 2013, https://doi.org/10.6110/KJACR.2013.25.6.297
- The feasibility study for the building integrated geothermal system using the horizontal heat exchanger vol.35, pp.1, 2015, https://doi.org/10.7836/kses.2015.35.1.081
- Feasibility Study of High-Efficiency Ground Heat Exchanger using Double U-tube through a Real-Scale Experiment vol.17, pp.4, 2017, https://doi.org/10.12813/kieae.2017.17.4.033