DOI QR코드

DOI QR Code

Seismic Performance Evaluation According to Seismic Retrofit Techniques of Existing School Buildings

기존 학교건축물의 내진보강기법에 따른 내진성능평가

  • Kang, Jong (Dept. of Architectural Engineering Tong Myong University)
  • 강종 (동명대학교, 건축공학과)
  • Received : 2012.01.07
  • Accepted : 2012.02.24
  • Published : 2012.02.28

Abstract

Reinforced concrete shear walls and X-type steel braces were applied in seismic retrofit techniques for seismic performance evaluation of school buildings constructed in accordance with standard design announced by the ordinance of the ministry of construction in 1980s. Seismic performance evaluation was based on FEMA 356 using response spectrum as elastic analysis and conducted to pushover analysis with nonlinear static analysis. The maximum displacement ratio between floors in 4th and 3rd floors of the existing school buildings was less than 1.0%, which was functioning level in FEMA 356. However, because plastic hinge occurs somewhat in structural members according to the results of pushover analysis, partial reinforcement will be required. X-direction of the maximum lateral displacement of reinforced concrete shear walls than X-type steel braces was 45% and 32% in 4th and 3rd floors of school buildings, and Y-direction was 18% and 17%, respectively.

Keywords