References
- Bridwell KH, Sedgewick TA, O'Brien MF, Lenke LG, Baldus C : The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 6 : 461-472, 1993 https://doi.org/10.1097/00002517-199306060-00001
- Cardoso MJ, Dmitriev AE, Helgeson M, Lehman RA, Kuklo TR, Rosner MK : Does superior-segment facet violation or laminectomy destabilize the adjacent level in lumbar transpedicular fixation? An in vitro human cadaveric assessment. Spine (Phila Pa 1976) 33 : 2868-2873, 2008 https://doi.org/10.1097/BRS.0b013e31818c63d3
- Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, McAfee PC : The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure : an in vitro biomechanical analysis. Spine (Phila Pa 1976) 22 : 2655-2663, 1997 https://doi.org/10.1097/00007632-199711150-00014
- Dickman CA, Fessler RG, MacMillan M, Haid RW : Transpedicular screw-rod fixation of the lumbar spine : operative technique and outcome in 104 cases. J Neurosurg 77 : 860-870, 1992 https://doi.org/10.3171/jns.1992.77.6.0860
- Esses SI, Sachs BL, Dreyzin V : Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976) 18 : 2231-2238; discussion 2239, 1993 https://doi.org/10.1097/00007632-199311000-00015
- Fischgrund JS, Mackay M, Herkowitz HN, Brower R, Montgomery DM, Kurz LT : 1997 Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis : a prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation. Spine (Phila Pa 1976) 22 : 2807-2812, 1997 https://doi.org/10.1097/00007632-199712150-00003
- Ghiselli G, Wang JC, Hsu WK, Dawson EG : L5-S1 segment survivorship and clinical outcome analysis after L4-L5 isolated fusion. Spine (Phila Pa 1976) 12 : 1275-1280; discussion 1280, 2003
- Hilibrand AS, Robbins M : Adjacent segment degeneration and adjacent segment disease : the consequences of spinal fusion? Spine J 4 :190S-194S, 2004 https://doi.org/10.1016/j.spinee.2004.07.007
- Jutte PC, Castelein RM : Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11 : 594-598, 2002 https://doi.org/10.1007/s00586-002-0469-8
- Karahalios DG, Kaibara T, Porter RW, Kakarla UK, Reyes PM, Baaj AA, et al. : Biomechanics of a lumbar interspinous anchor with anterior lumbar interbody fusion. J Neurosurg Spine 12 : 372-380, 2010 https://doi.org/10.3171/2009.10.SPINE09305
- Lafage V, Gangnet N, Sénégas J, Lavaste F, Skalli W : New interspinous implant evaluation using an in vitro biomechanical study combined with a finite-element analysis. Spine (Phila Pa 1976) 32 : 1706-1713, 2007 https://doi.org/10.1097/BRS.0b013e3180b9f429
- Lee CK, Langrana NA : Lumbosacral spinal fusion. A biomechanical study. Spine (Phila Pa 1976) 9 : 574-581, 1984 https://doi.org/10.1097/00007632-198409000-00007
- Papp T, Porter RW, Aspden RM, Shepperd JA : An in vitro study of the biomechanical effects of flexible stabilization on the lumbar spine. Spine (Phila Pa 1976) 22 : 151-155, 1997 https://doi.org/10.1097/00007632-199701150-00005
- Park P, Garton HJ, Gala VC, Hoff JT, McGillicuddy JE : Adjacent segment disease after lumbar or lumbosacral fusion : review of the literature. Spine (Phila Pa 1976) 29 : 1938-1944, 2004 https://doi.org/10.1097/01.brs.0000137069.88904.03
- Schlegel JD, Smith JA, Schleusener RL : Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine (Phila Pa 1976) 21 : 970-981, 1996 https://doi.org/10.1097/00007632-199604150-00013
- Schnake KJ, Schaeren S, Jeanneret B : Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine (Phila Pa 1976) 31 : 442-449, 2006 https://doi.org/10.1097/01.brs.0000200092.49001.6e
- Schulte TL, Leistra F, Bullmann V, Osada N, Vieth V, Marquardt B, et al. : Disc height reduction in adjacent segments and clinical outcome 10 years after lumbar 360 degrees fusion. Eur Spine J 16 : 2152-2158, 2007 https://doi.org/10.1007/s00586-007-0515-7
- Sonntag VK, Marciano FF : Role of spinal instrumentation in fusion for degenerative disease of the lumbosacral spine. West J Med 162 : 262- 263, 1995
- Thomsen K, Christensen FB, Eiskjaer SP, Hansen ES, Fruensgaard S, Bünger CE : 1997 Volvo Award winner in clinical studies. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion : a prospective, randomized clinical study. Spine (Phila Pa 1976) 22 : 2813-2822, 1997 https://doi.org/10.1097/00007632-199712150-00004
- Wang JC, Haid RW Jr, Miller JS, Robinson JC : Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005. J Neurosurg Spine 4 : 132-136, 2006 https://doi.org/10.3171/spi.2006.4.2.132
- Wang JC, Spenciner D, Robinson JC : SPIRE spinous process stabilization plate : biomechanical evaluation of a novel technology. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005. J Neurosurg Spine 4 : 160-164, 2006 https://doi.org/10.3171/spi.2006.4.2.160
- West JL 3rd, Ogilvie JW, Bradford DS : Complications of the variable screw plate pedicle screw fixation. Spine (Phila Pa 1976) 16 : 576-579, 1991 https://doi.org/10.1097/00007632-199105000-00016
- Zdelblick TA : A prospective, randomized study of lumbar fusion. Preliminary results. Spine (Phila Pa 1976) 18 : 983-991, 1993 https://doi.org/10.1097/00007632-199306150-00006
Cited by
- Biomechanical analysis of an interspinous fusion device as a stand-alone and as supplemental fixation to posterior expandable interbody cages in the lumbar spine : Laboratory investigation vol.20, pp.2, 2012, https://doi.org/10.3171/2013.10.spine13612
- Effect of Device Rigidity and Physiological Loading on Spinal Kinematics after Dynamic Stabilization : An In-Vitro Biomechanical Study vol.58, pp.5, 2015, https://doi.org/10.3340/jkns.2015.58.5.412
- Comparison of the Efficacy and Safety between Interspinous Process Distraction Device and Open Decompression Surgery in Treating Lumbar Spinal Stenosis: A Meta Analysis vol.28, pp.1, 2015, https://doi.org/10.3109/08941939.2014.932474
- Interspinous fusion device: A systematic review of clinical and biomechanical evidence vol.8, pp.11, 2012, https://doi.org/10.1177/1687814016680517
- Biomechanical Comparison of Spinal Fusion Methods Using Interspinous Process Compressor and Pedicle Screw Fixation System Based on Finite Element Method vol.59, pp.2, 2012, https://doi.org/10.3340/jkns.2016.59.2.91
- Lumbar Interspinous Process Fixation and Fusion with Stand-Alone Interlaminar Lumbar Instrumented Fusion Implant in Patients with Degenerative Spondylolisthesis Undergoing Decompression for Spinal Ste vol.10, pp.1, 2012, https://doi.org/10.4184/asj.2016.10.1.27
- A Novel Nonpedicular Screw-Based Fixation in Lumbar Spondylolisthesis vol.2017, pp.None, 2012, https://doi.org/10.1155/2017/5619350
- The limited area decompression, intervertebral fusion, and pedicle screw fixation for treating degenerative lumbar spinal stenosis with instability : Follow-up at least 12 months an observational stu vol.98, pp.50, 2012, https://doi.org/10.1097/md.0000000000018277
- Biomechanical analysis of a newly developed interspinous process device conjunction with interbody cage based on a finite element model vol.15, pp.12, 2012, https://doi.org/10.1371/journal.pone.0243771
- Biomechanical analysis of lumbar interbody fusion supplemented with various posterior stabilization systems vol.30, pp.8, 2012, https://doi.org/10.1007/s00586-021-06856-7