참고문헌
- Nissen SE, Gurley JC, Grines CL, et al. Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease. Circulation 1991;84:1087-1099. https://doi.org/10.1161/01.CIR.84.3.1087
- Nissen SE, Gurley JC. Application of intravascular ultrasound for detection and quantitation of coronary atherosclerosis. Int J Card Imaging 1991;6:165-177. https://doi.org/10.1007/BF01797849
- Waller BF, Pinkerton CA, Slack JD. Intravascular ultrasound: a histological study of vessels during life: the new 'gold standard' for vascular imaging. Circulation 1992;85:2305-2310. https://doi.org/10.1161/01.CIR.85.6.2305
- Schiele F, Meneveau N, Seronde MF, et al. Medical costs of intravascular ultrasound optimization of stent deployment: results of the multicenter randomized 'REStenosis after Intravascular ultrasound STenting' (RESIST) study. Int J Cardiovasc Intervent 2000;3:207-213. https://doi.org/10.1080/14628840050515957
- Smith SC Jr, Feldman TE, Hirshfeld JW Jr, et al. ACC/AHA/ SCAI 2005 Guideline Update for Percutaneous Coronary Intervention- summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to Update the 2001 Guidelines for Percutaneous Coronary Intervention). Circulation 2006;113:156-175. https://doi.org/10.1161/CIRCULATIONAHA.105.557561
- Nakamura S, Colombo A, Gaglione A, et al. Intracoronary ultrasound observations during stent implantation. Circulation 1994;89:2026-2034. https://doi.org/10.1161/01.CIR.89.5.2026
- Gorge G, Haude M, Ge J, et al. Intravascular ultrasound after low and high inflation pressure coronary artery stent implantation. J Am Coll Cardiol 1995;26:725-730. https://doi.org/10.1016/0735-1097(95)00211-L
- Mudra H, Klauss V, Blasini R, et al. Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter. Circulation 1994;90:1252-1261. https://doi.org/10.1161/01.CIR.90.3.1252
- Brodie BR, Cooper C, Jones M, Fitzgerald P, Cummins F; Postdilatation Clinical Compartative Study (POSTIT) Investigators. Is adjunctive balloon postdilatation necessary after coronary stent deployment? Final results from the POSTIT trial. Catheter Cardiovasc Interv 2003;59:184-192. https://doi.org/10.1002/ccd.10474
- de Ribamar Costa J Jr, Mintz GS, Carlier SG, et al. Intravascular ultrasound assessment of drug-eluting stent expansion. Am Heart J 2007;153:297-303. https://doi.org/10.1016/j.ahj.2006.08.026
- Alfonso F, Goicolea J, Hernandez R, et al. Arterial perforation during optimization of coronary stents using high-pressure balloon inflations. Am J Cardiol 1996;78:1169-1172. https://doi.org/10.1016/S0002-9149(96)90075-2
- Mintz GS, Weissman NJ. Intravascular ultrasound in the drugeluting stent era. J Am Coll Cardiol 2006;48:421-429. https://doi.org/10.1016/j.jacc.2006.04.068
- Cook S, Wenaweser P, Togni M, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 2007;115:2426-2434. https://doi.org/10.1161/CIRCULATIONAHA.106.658237
- Hwang CW, Wu D, Edelman ER. Physiological transport forces govern drug distribution for stent-based delivery. Circulation 2001;104:600-605. https://doi.org/10.1161/hc3101.092214
- Papafaklis MI, Chatzizisis YS, Naka KK, Giannoglou GD, Michalis LK. Drug-eluting stent restenosis: Effect of drug type, release kinetics, hemodynamics and coating strategy. Pharmacol Ther 2011 Dec 22 [Epub]. http://dx.doi.org/10.1016/j.pharmthera.2011.12.006.
- Hwang CW, Edelman ER. Arterial ultrastructure influences transport of locally delivered drugs. Circ Res 2002;90:826-832. https://doi.org/10.1161/01.RES.0000016672.26000.9E
- Windecker S, Meier B. Late coronary stent thrombosis. Circulation 2007;116:1952-1965. https://doi.org/10.1161/CIRCULATIONAHA.106.683995
- Kume T, Waseda K, Ako J, et al. Intravascular ultrasound assessment of postprocedural incomplete stent apposition. J Invasive Cardiol 2012;24:13-16.
- Fitzgerald PJ, Oshima A, Hayase M, et al. Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study. Circulation 2000;102:523-530. https://doi.org/10.1161/01.CIR.102.5.523
- Uren NG, Schwarzacher SP, Metz JA, et al. Predictors and outcomes of stent thrombosis: an intravascular ultrasound registry. Eur Heart J 2002;23:124-132. https://doi.org/10.1053/euhj.2001.2707
- Doi H, Maehara A, Mintz GS, et al. Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxeleluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials. JACC Cardiovasc Interv 2009;2:1269-1275. https://doi.org/10.1016/j.jcin.2009.10.005
- Hong MK, Mintz GS, Lee CW, et al. Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation. Eur Heart J 2006;27:1305-1310. https://doi.org/10.1093/eurheartj/ehi882
- Cheneau E, Leborgne L, Mintz GS, et al. Predictors of subacute stent thrombosis: results of a systematic intravascular ultrasound study. Circulation 2003;108:43-47. https://doi.org/10.1161/01.CIR.0000078636.71728.40
- Fujii K, Carlier SG, Mintz GS, et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol 2005;45:995-998. https://doi.org/10.1016/j.jacc.2004.12.066
- Kimura M, Mintz GS, Carlier S, et al. Outcome after acute incomplete sirolimus-eluting stent apposition as assessed by serial intravascular ultrasound. Am J Cardiol 2006;98:436-442. https://doi.org/10.1016/j.amjcard.2006.02.050
- Hong MK, Lee CW, Kim JH, et al. Impact of various intravascular ultrasound criteria for stent optimization on the sixmonth angiographic restenosis. Catheter Cardiovasc Interv 2002;56:178-183. https://doi.org/10.1002/ccd.10205
- Albiero R, Rau T, Schluter M, et al. Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions. Circulation 1997;96:2997-3005. https://doi.org/10.1161/01.CIR.96.9.2997
- Hoffmann R, Mintz GS, Mehran R, et al. Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents. J Am Coll Cardiol 1998;31:43-49. https://doi.org/10.1016/S0735-1097(98)80842-5
- Kasaoka S, Tobis JM, Akiyama T, et al. Angiographic and intravascular ultrasound predictors of in-stent restenosis. J Am Coll Cardiol 1998;32:1630-1635. https://doi.org/10.1016/S0735-1097(98)00404-5
- Moussa I, Moses J, Di Mario C, et al. Does the specific intravascular ultrasound criterion used to optimize stent expansion have an impact on the probability of stent restenosis? Am J Cardiol 1999;83:1012-1017. https://doi.org/10.1016/S0002-9149(99)00006-5
- Blasini R, Neumann FJ, Schmitt C, Bokenkamp J, Schomig A. Comparison of angiography and intravascular ultrasound for the assessment of lumen size after coronary stent placement: impact of dilation pressures. Cathet Cardiovasc Diagn 1997;42:113-119. https://doi.org/10.1002/(SICI)1097-0304(199710)42:2<113::AID-CCD2>3.0.CO;2-G
- Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-1323. https://doi.org/10.1056/NEJMoa035071
- Colombo A, Drzewiecki J, Banning A, et al. Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003;108:788-794. https://doi.org/10.1161/01.CIR.0000086926.62288.A6
- Park SJ, Kim YH, Park DW, et al. Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis. Circ Cardiovasc Interv 2009;2:167-177. https://doi.org/10.1161/CIRCINTERVENTIONS.108.799494
- Kim SH, Kim YH, Kang SJ, et al. Long-term outcomes of intravascular ultrasound-guided stenting in coronary bifurcation lesions. Am J Cardiol 2010;106:612-618. https://doi.org/10.1016/j.amjcard.2010.04.016
- Mintz GS, Painter JA, Pichard AD, et al. Atherosclerosis in angiographically "normal" coronary artery reference segments: an intravascular ultrasound study with clinical correlations. J Am Coll Cardiol 1995;25:1479-1485. https://doi.org/10.1016/0735-1097(95)00088-L
- Weissman NJ, Palacios IF, Nidorf SM, Dinsmore RE, Weyman AE. Three-dimensional intravascular ultrasound assessment of plaque volume after successful atherectomy. Am Heart J 1995;130:413-419. https://doi.org/10.1016/0002-8703(95)90345-3
- Morino Y, Tamiya S, Masuda N, et al. Intravascular ultrasound criteria for determination of optimal longitudinal positioning of sirolimus-eluting stents. Circ J 2010;74:1609-1616. https://doi.org/10.1253/circj.CJ-10-0025
- de Jaegere P, Mudra H, Figulla H, et al. Intravascular ultrasound- guided optimized stent deployment: Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting In Coronaries Study (MUSIC Study). Eur Heart J 1998;19:1214-1223. https://doi.org/10.1053/euhj.1998.1012
- Russo RJ, Silva PD, Teirstein PS, et al. A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial). Circ Cardiovasc Interv 2009;2:113-123. https://doi.org/10.1161/CIRCINTERVENTIONS.108.778647
- Oemrawsingh PV, Mintz GS, Schalij MJ, Zwinderman AH, Jukema JW, van der Wall EE. Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study). Circulation 2003;107:62-67. https://doi.org/10.1161/01.CIR.0000043240.87526.3F
- Mudra H, di Mario C, de Jaegere P, et al. Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study). Circulation 2001;104:1343-1349. https://doi.org/10.1161/hc3701.096064
- Casella G, Klauss V, Ottani F, Siebert U, Sangiorgio P, Bracchetti D. Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting. Catheter Cardiovasc Interv 2003;59:314-321. https://doi.org/10.1002/ccd.10537
- Parise H, Maehara A, Stone GW, Leon MB, Mintz GS. Metaanalysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in pre-drug-eluting stent era. Am J Cardiol 2011;107:374-382. https://doi.org/10.1016/j.amjcard.2010.09.030
- Jakabcin J, Spacek R, Bystron M, et al. Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial: HOME DES IVUS. Catheter Cardiovasc Interv 2010;75:578-583. https://doi.org/10.1002/ccd.22244
- Colombo A, Caussin C, Presbitero P, Chieffo A. AVIO: a prospective, randomized trial of intravascular-ultrasound guided compared to angiography guided stent implantation in complex coronary lesions [abstract]. J Am Coll Cardiol 2010;56:xvii.
- Roy P, Steinberg DH, Sushinsky SJ, et al. The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents. Eur Heart J 2008;29:1851-1857. https://doi.org/10.1093/eurheartj/ehn249
- Okabe T, Mintz GS, Buch AN, et al. Intravascular ultrasound parameters associated with stent thrombosis after drug-eluting stent deployment. Am J Cardiol 2007;100:615-620. https://doi.org/10.1016/j.amjcard.2007.03.072
- Choi SY, Witzenbichler B, Maehara A, et al. Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy. Circ Cardiovasc Interv 2011;4:239-247. https://doi.org/10.1161/CIRCINTERVENTIONS.110.959791
- Sonoda S, Morino Y, Ako J, et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol 2004;43:1959-1963. https://doi.org/10.1016/j.jacc.2004.01.044
- Takebayashi H, Kobayashi Y, Mintz GS, et al. Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation. Am J Cardiol 2005;95:498-502. https://doi.org/10.1016/j.amjcard.2004.10.020
- Hong MK, Park SW, Lee NH, et al. Long-term outcomes of minor dissection at the edge of stents detected with intravascular ultrasound. Am J Cardiol 2000;86:791-795, A9. https://doi.org/10.1016/S0002-9149(00)01085-7
- Liu X, Tsujita K, Maehara A, et al. Intravascular ultrasound assessment of the incidence and predictors of edge dissections after drug-eluting stent implantation. JACC Cardiovasc Interv 2009;2:997-1004.
- Park SM, Kim JS, Ko YG, et al. Angiographic and intravascular ultrasound follow up of paclitaxel- and sirolimus-eluting stent after poststent high-pressure balloon dilation: from the poststent optimal stent expansion trial. Catheter Cardiovasc Interv 2011;77:15-21. https://doi.org/10.1002/ccd.22635
- Hur SH, Kang SJ, Kim YH, et al. Impact of intravascular ultrasound- guided percutaneous coronary intervention on longterm clinical outcomes in a real world population. Catheter Cardiovasc Interv 2011 Jul 29 [Epub]. http://dx.doi.org/10.1002/ccd.23279.
피인용 문헌
- The impact of the ambulance with the physician (the Doctor Car) to the primary percutaneous coronary intervention for the ST-elevation myocardial infarction vol.19, pp.1, 2012, https://doi.org/10.7793/jcoron.19.500
- Clinical and Angiographic Outcomes with Everolimus Eluting Stents for the Treatment of Cardiac Allograft Vasculopathy vol.27, pp.1, 2012, https://doi.org/10.1111/joic.12071
- Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound vol.30, pp.2, 2012, https://doi.org/10.1007/s10554-013-0330-7
- Ischemia-guided Revascularization for Stable Ischemic Heart Disease vol.87, pp.6, 2012, https://doi.org/10.3904/kjm.2014.87.6.675
- Design Optimisation of Coronary Artery Stent Systems vol.44, pp.2, 2012, https://doi.org/10.1007/s10439-015-1373-9
- Usefulness of Frequency Domain Optical Coherence Tomography Compared with Intravascular Ultrasound as a Guidance for Percutaneous Coronary Intervention vol.29, pp.2, 2016, https://doi.org/10.1111/joic.12276
- Computer-aided detection of intracoronary stent in intravascular ultrasound sequences : Computer-aided detection of intracoronary stent in intravascular ultrasound sequences vol.43, pp.10, 2012, https://doi.org/10.1118/1.4962927
- Co‐registration of angiography and intravascular ultrasound images through image‐based device tracking vol.88, pp.7, 2012, https://doi.org/10.1002/ccd.26340
- Small side branch compromise related to main vessel stenting : A retrospective cohort study comparing different treatment strategies vol.97, pp.35, 2018, https://doi.org/10.1097/md.0000000000011961
- Impact of Malapposed and Overlapping Stents on Hemodynamics: A 2D Parametric Computational Fluid Dynamics Study vol.9, pp.8, 2021, https://doi.org/10.3390/math9080795