DOI QR코드

DOI QR Code

Gas Typed Digital X-ray Image Sensor Using PDP Fabrication Process

PDP공정을 이용한 가스 방식의 디지털 X-ray 영상 센서

  • Kim, Chang Man (Biomedical IT Convergence Center, Gumi Electronics & Information Technology Research Institute) ;
  • Kim, Si Hyung (School of Electronic Engineering, Kumoh National Institute of Technology) ;
  • Nam, Ki Chang (Clinical Trials Center for Medical Devices, Severance Hospital) ;
  • Kim, Sang Hee (School of Electronic Engineering, Kumoh National Institute of Technology) ;
  • Song, Kwang Soup (Medical IT Convergence Engineering, Kumoh National Institute of Technology)
  • 김창만 (구미전자정보기술원 IT의료융합기술사업단) ;
  • 김시형 (금오공과대학교 전자공학부) ;
  • 남기창 (세브란스병원 의료기기 임상시험 센터) ;
  • 김상희 (금오공과대학교 전자공학부) ;
  • 송광섭 (금오공과대학교 메디컬IT융합공학과)
  • Received : 2012.07.18
  • Published : 2012.09.25

Abstract

Parallel-plate-type scanning sensors have been commercially used for X-ray imaging sensors. In this study, we manufactured the scan typed 1D X-ray image sensor that can be used to obtain scanning images, by using the plasma display panel (PDP) fabrication process. We fabricated drift and pixel electrodes in the glass chamber and injected Xe gas at atmospheric pressure. We evaluated the intensity of a pixel signal depending on the bias voltage on the drift electrode and investigated the characteristics of shielding effect on the single pixel using lead (Pb). The adsorption rate of X-ray photon is low (4%) on the soda lime glass (1.1mm) and the electrical signal detected on the X-ray sensor was increased in the high bias voltage. We acquired digital X-ray scanning image with our DAS (data acquisition system) and sensor scanning system.

마주보는 2개의 병렬전극을 이용한 스캔 방식의 디지털 X-ray 영상 센서는 많은 발전을 해왔으며 상업용으로 널리 이용되고 있다. 본 연구에서는 PDP(plasma display panel) 제조 공정에서 사용되고 있는 글라스 재질에 silver paste 전극을 이용하여 드리프트 전극과 픽셀 전극이 있는 챔버를 형성하고 챔버내에 X-ray와 반응하는 Xe 가스를 주입하여 스캔 방식의 1D X-ray 영상 센서를 제작하였다. 드리프트 전극의 바이어스 전압 크기에 따른 싱글 픽셀의 X-ray 신호 크기를 평가하였으며 납(Pb)을 이용하여 싱글 픽셀을 차폐하였을 경우와 차폐하지 않았을 때의 싱글 픽셀 신호 특성을 조사하였다. X-ray 흡수율(4%)은 소다 라임(soda lime, 1.1mm) 글라스에서 가장 낮았으며 센서에서 검출되는 전기적 신호는 드리프트 전극에 인가하는 전압이 클수록 증가하였다. 그리고 자체 제작한 DAS(data acquisition system) 및 센서 스캐닝 시스템을 이용하여 디지털 영상을 구현하였다.

Keywords

References

  1. M. Yun, S. Cho, K. Oh, M. Kim, S. Jung, G. Jang, S. Heo, C. Kwon, S. H. Nam, "Measurement of the properties of a flat-panel gas X-ray detector", Nucl. Instrum. Meth. A, Vol. 607, pp. 162-165, 2009. https://doi.org/10.1016/j.nima.2009.03.174
  2. 차보경, 이동훈, 김봉회, 황윤금, 전성채, 허영, "디지털 3D 투시 X-ray 영상 센서용 섬광체 연구개발", 대한전자공학회 2010년 하계학술대회, 제 33 권 제1호, 2025-2027쪽, 2010.
  3. E.A. Babichev, S.E. Baru, A.G. Khabakhpashev, G.M. Kolachev, V.V. Neustroev, Y.N. Pestov, O.A. Ponomarev, G.M. Savinov, L.I. Shekhtman, D.J. Miller, "High pressure multiwire proportional and gas microstrip chambers for medical radiology" Nucl. Instrum. Meth. A, Vol.360, pp. 271-276, 1995. https://doi.org/10.1016/0168-9002(95)00097-6
  4. H.-J. Besch, "Gaseous detectors for synchrotron radiation applications in medical radiology", Nucl. Instrum. Meth. A, Vol. 360, pp. 277-282, 1995. https://doi.org/10.1016/0168-9002(95)00098-4
  5. V.R. Groshev, V.R. Kozak, V.I. Nifontov, S.M. Pishenuok, A.A. Samsonov, L.I. Shekhtman*, V.I. Telnov, "Digital mammography with multi-electrode ionization chamber", Nucl. Instrum. Meth. A, Vol. 454, pp 130-135, 2000. https://doi.org/10.1016/S0168-9002(00)00814-7
  6. E.A. Babichev, S.E. Baru, V.R. Groshev*, A.G. Khabakhpashev, V.V. Leonov, V.A. Neustroev, V.V. Porosev, G.A. Savinov, L.I. Shekhtman, "The new effective detector for digital scanning radiography", Nucl. Instrum. Meth. A, Vol. 513, pp. 57-60, 2003. https://doi.org/10.1016/j.nima.2003.08.001
  7. C. Iacobaeus, T. Francke, B Lund-Jensen, V. Peskov, "An X-ray scanner prototype based on a novel hybrid gaseous detector", Nucl. Instrum. Meth. A, Vol. 573, pp. 61-64, 2007. https://doi.org/10.1016/j.nima.2006.10.252
  8. Mei Li, Madhu S. Dixit, Paul C. Johns, "Photon-counting digital radiography using high-pressure xenon filled detector", Nucl. Instrum. Meth. A, Vol. 471, pp. 215-221, 2001. https://doi.org/10.1016/S0168-9002(01)01102-0
  9. G.S. Cho, D.W. Kang, and K.H. Kim, "The Performance of X-ray Scanner Using Ceramic Scintillator Base Detector Module", IEEE Transactions on Nuclear Science, Vol. 55, No.3, pp.1321-1326, 2008. https://doi.org/10.1109/TNS.2008.924074