Abstract
In this study, the possibility of applying the damping devices to shear-wall dominant apartment buildings(SDA) was examined. In order to achieve research objectives, ASCE/SEI 7-10 design procedure for structures with damping systems applied to four representative apartment buildings which are under design or previously designed with the shear-wall dominant system, and the performances of damping devices were investigated. It is shown that in order to secure the seismic performance of SDA by using dampers, the stiffness of the dampers should be very large because of the effects of shear walls with the high elastic stiffness. But since this large stiffness is highly difficult to implement in reality, prudent decisions have to be made in designing the SDA with damping system and friction dampers with the high initial stiffness are more effective than hysteretic steel dampers.
이 연구에서는 국내 아파트 건물의 주요 횡력저항시스템인 전단벽식 구조를 대상으로 제진장치의 적용 가능성을 검토해 보았다. 연구목적 달성을 위하여 ASCE/SEI 7-10 제진구조물 설계방법을 현재 설계 중이거나 이전에 설계된 4개의 대표적인 전단벽식 아파트에 적용하여 내진성능 확보를 위하여 요구되는 제진장치의 성능에 대하여 조사하였다. 연구결과, 전단벽식 아파트에 제진장치를 이용하여 내진성능을 확보하기 위해서는 탄성강성이 높은 전단벽의 영향으로 인하여 제진장치의 강성이 매우 커야 함을 알 수 있었다. 이와 같은 높은 강성의 제진장치는 현실적으로 구현하기 매우 어려울 수 있으므로 전단벽식 건물에 제진장치를 설계할 때 주의하여야 하며, 벽량이 많은 전단벽식 건물의 경우 강재이력형 제진장치의 적용에 한계가 있는 것으로 판단된다.