DOI QR코드

DOI QR Code

Comparative Study of Color Correspondence According to Size of Vita CAD/CAM Ceramic Block Using ShadeEye-Ncc$^{(R)}$ System

ShadeEye$^{(R)}$ NCC system을 이용한 Vita CAD/CAM Ceramic Block의 크기에 따른 색조 일치성 비교연구

  • Kim, Jae-Hong (Department of Health Science Specialized in Dental Lab. Science & Engineering Graduate School Korea University) ;
  • Kim, Hae-Young (Department of Health Science Specialized in Dental Lab. Science & Engineering Graduate School Korea University) ;
  • Kim, Woong-Chul (Department of Health Science Specialized in Dental Lab. Science & Engineering Graduate School Korea University) ;
  • Kim, Ji-Hwan (Department of Health Science Specialized in Dental Lab. Science & Engineering Graduate School Korea University)
  • 김재홍 (고려대학교 대학원 보건과학과 치의기공) ;
  • 김혜영 (고려대학교 대학원 보건과학과 치의기공) ;
  • 김웅철 (고려대학교 대학원 보건과학과 치의기공) ;
  • 김지환 (고려대학교 대학원 보건과학과 치의기공)
  • Received : 2011.07.27
  • Accepted : 2011.09.20
  • Published : 2011.09.30

Abstract

Purpose: The purpose of this study was to compare color correspondence of different sizes of Vita Mark II$^{(R)}$ and TriLuxe$^{(R)}$ Feldspar blocks. Methods: The three commercially available shades(1M2, 2M2, 3M2) of Mark II & TriLuxe blocks for the CEREC$^{(R)}$ CAD/CAM system were examined. For each of three colors, three different sizes were tested, 5 blocks each. The measurements were made using a spectrophotometer equipped with an integrating sphere using the CIE $L^*$, $a^*$, $b^*$ colorimetric system. Results: The $L^*$, $a^*$, $b^*$ value of Vita Mark II$^{(R)}$ ceramic block showed significantly higher than TriLuxe$^{(R)}$ ceramic block(p<0.05). In comparing the Vita Mark II$^{(R)}$ specimen of the three different shade, color differences between materials(${\Delta}E^*$) showed the lowest value of 2.09, and the highest was 2.24. ${\Delta}E^*$ values of the materials of Vita Mark II$^{(R)}$ were higher than 2. As the size of ceramic block differed, the color correspondence of Vita Mark II$^{(R)}$ showed statistically significant difference but, this result is clinically acceptable. Conclusion: All the different sizes of the different shades of Vita TriLuxe$^{(R)}$ blocks for the CEREC$^{(R)}$ system showed the high degree of color correspondence necessary in industrially prefabricated CAD/CAM blocks. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

Keywords

References

  1. 류소영, 임주환, 조인호. 도재 전장주조관에서 사용되는 도재의 색 안정성에 관한 연구. 대한치과보철학회지, 38(3), 73-84, 2000.
  2. 이승택, 이종혁, 신수연. 색조 선택 시스템을 이용한 shade guide의 색조분석. 대한치과보철학회지, 47(1), 1-11, 2009.
  3. 이태일, 안진수, 김영수, 신상완. 2종의 측색기에 의한 도재 색조 재현의 정확성 비교. 대한치과보철학회지, 47(4), 348-355, 2009.
  4. Bindl A, Mormann WH. Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns. Eur J Oral Sci, 111(2), 163-169, 2003. https://doi.org/10.1034/j.1600-0722.2003.00022.x
  5. Vita Zahnfabrik H.Rauter GmbH & Co. KG, CAD/CAM Blocks - how are they actually produced? Vita Zahnfabrik technical bulletin 1516E, 4, 2008.
  6. Giordano R. Materials for chairside restorations CAD/CAM produced. J Am Dent Assoc, 137 (1), 14-21, 2006.
  7. Mormann WH. The evolution of the CEREC system. J Am Dent Assoc, Sep, 137 Suppl, 7S-13S, 2006.
  8. O'Brien WJ, Groh CL, Boenke KM. A new, small-color-difference equation for dental shade. J Dent Res, 69(11), 1762-1764, 1990. https://doi.org/10.1177/00220345900690111001
  9. Seghi RR, Johnson WM, O'Brien WJ. Spectrophotometric analysis of color differences between porcelain systems. J Prosthet Dent, 56(4), 35-40, 1986. https://doi.org/10.1016/0022-3913(86)90279-9
  10. Spear F, Holloway J. Which all ceramic system is optimal for anterior esthetics? J Am Dent Assoc, 139(2), 19S-24S, 2008.
  11. Strub JR, Rekow ED, Witkowski S. Computer-aided design and fabrication of dental restorations: current systems and future possibilities. J Am Dent Assoc, 137(1), 1289-1296, 2006. https://doi.org/10.14219/jada.archive.2006.0389
  12. Vichi A, Fraioli A, Davidson CL, Ferrari M. Influence of thickness on color in multilayering technique. Dent Mater, 23(4), 1584-1589, 2007. https://doi.org/10.1016/j.dental.2007.06.026
  13. Wozniak WT. Proposed guidelines for the acceptance program for dental shade guides. American Dental Association, Chicago, 1-2, 1987.

Cited by

  1. 열가압성형도재 코어의 가시광선 투과율에 관한 연구 vol.34, pp.1, 2012, https://doi.org/10.14347/kadt.2012.34.1.001