사이클로헥사논의 화재 및 폭발 특성치의 측정 및 고찰

The Measurement and Investigation of Fire and Explosion Characteristics of Cyclohexanone

  • 하동명 (세명대학교 보건안전공학과)
  • 투고 : 2011.03.30
  • 심사 : 2011.08.12
  • 발행 : 2011.08.31

초록

사이클로헥사논의 안전한 취급을 위해서 $25^{\circ}C$에서 폭발한계를 고찰하였고, 실험장치를 이용하여 하부 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 공정의 안전을 위해서 사이클로헥사논의 폭발하한계는 1.1 Vol.%($100^{\circ}C$), 상한계는 9.4 Vol.%를 추천하였고, 하부인화점은 밀폐계에서 $42{\sim}43^{\circ}C$와 개방식에서 $49{\sim}51^{\circ}C$로 측정되었다. ASTM E659-78 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 여기서 측정된 최소자연발화온도는 $415^{\circ}C$였다.

For the safe handling of cyclohexanone, the explosion limits at $25^{\circ}C$ were investigated. The lower flash points and AITs (auto-ignition temperatures) by ignition time delay for cyclohexanone were experimented. By using the literatures data, the lower and upper explosion limits of cyclohexanone recommended 1.1 Vol.% ($100^{\circ}C$) and 9.4 Vol.%, respectively. The lower flash points of cyclohexanone were experimented $42{\sim}43^{\circ}C$ by using closed-cup tester and $49{\sim}51^{\circ}C$ by using open cup tester. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for cyclohexanone and the experimental AIT of cyclohexanone was $415^{\circ}C$.

키워드

참고문헌

  1. A.A. Kline, C.R. Szydlik, T.N. Rogers, and M.E. Mullins, "An Overview of Compiling, Critically Evaluating, and Delivering Reliable Property Data AIChE DIPPER Project 911 and 912", Fluid Phase Equilibria, Vol.150-151, pp.421-428(1998).
  2. R.E. Montemayor, J.E. Rogerson, J.C. Colbert, and S.B. Schiller, "Reference Verification Fluids for Flash point Determination", J. of Testing and Evaluation, Vol.27, No.6, pp.423-427(1999). https://doi.org/10.1520/JTE12171J
  3. R.E. Montemayor, M.A. Collier, and G.G. Lazarczyk, "Precision and Equivalence of Automatic and Manual Flash Point Apparatus", J. of Testing and Evaluation, Vol.30, No.1, pp.74-84(2002). https://doi.org/10.1520/JTE12291J
  4. J.C. Jones and J. Godefroy, "A Reappraisal of the Flash Point of Formic Acid", J. of Loss Prevention in the Process Industries, Vol.15, pp.241-243(2002). https://doi.org/10.1016/S0950-4230(01)00063-8
  5. L.G. Britton, "Two Hundred Years of Flammable Limits", Process Safety Progress, Vol.12, No.1, pp.1-11(2002).
  6. D.M. Ha and S.J. Lee "Measurement of Falsh Points and Autoignition Temperatures for Xylene Isomers", J. of the Korean Institute of Gas, Vol.13, No.2, pp.40-45(2009).
  7. M.G. Zabetakis, A.L. Furno, and G.W. Jones, "Minimum Spontaneous Ignition Temperature of Combustibles in Air", Industrial and Engineering Chemistry, Vol.46, No.10, pp.2173-2178(1954). https://doi.org/10.1021/ie50538a047
  8. S. Yagyu, "Systematization of Spontaneous Ignition Temperature of Organic Compounds -Spontaneous Ignition Temperature of Alkyl Alcohols-", Research Report of the Research Institute of Industrial Safety (RIIS-RR-26-5), Japan(1978).
  9. D. Kong, R.K. Eckhoff, and F. Alfert, "Auto-ignition of $CH_4/air$, $C_3H_8/air$, $CH_4/C_3H_8/air$and $CH_4/CO_2/air$ Using 1L Ignition Bomb", J. of Hazardous Materials, Vol.40, pp.68-84(1995).
  10. K.C. Smyth and N.P. Bryner, "Short-Duration Autoignition Temperature Measurement for Hydrocarbon Fuels Near Heated Metal Surfaces", Combustion Sci. and Tech., Vol.126, pp.225-253(1997). https://doi.org/10.1080/00102209708935675
  11. F-Y. Hshieh, D.B. Hirsh, and J.H. Willams, "Autoignition Temperature of Trichlorosilanes", Fire and Materials, Vol.26, pp.289-290(2002). https://doi.org/10.1002/fam.804
  12. D.M. Ha, "Characteristics of Auto-ignition for Trichlorosliane and Dichlorosilane-Trichlorosliane Mixtures", J. of the Korean Institute of Gas, Vol.14, No.4, pp.24-30(2010).
  13. NFPA, "Fire Hazard Properties of Flammable Liquid, Gases, and Volatile Solids", NFPA 325M, NFPA (1991).
  14. SFPE, "SFPE Handbook of Fire Protection Engineering", 2nd ed., SFPE(1995).
  15. V. Babrauskas, "Ignition Handbook", Fire Science Publishers, SFPE(2003).
  16. S.M. Stephenson, "Flash Points of Organic and Organometallic Compounds", Elsevier(1987).
  17. R.E. Lenga and K.L. Votoupal, "The Sigma Aldrich Library of Regulatory and Safety Data, Volume I- III", Sigma Chemical Company and Aldrich Chemical Company Inc.(1993).
  18. R.J. Lewis, "Sax's Dongerous Properties of Industrial Materials", 11th ed., John Wiley & son, Inc., New Jersey(2004).
  19. 柳生昭三, "蒸氣の爆發限界", 安全工學協會(1979).
  20. G.M. Zabetakis, "Flammability Characteristics of Combustible Gases and Vapors", US Bureau of Mines, Bulletin(1965).
  21. J.E. Hustad and O.K. Sonju, "Experimental Studies of Lower Flammability Limits of Gases and Mixtures of Gases at Elevated Temperature", Combustion and Flame, Vol.71, pp.283-294(1988). https://doi.org/10.1016/0010-2180(88)90064-8
  22. D.M. Ha, "Prediction of Temperature Dependence of Lower Explosive Limits for Paraffinic Hydrocarbons", J. of the Korean Institute for Industrial Safety, Vol.15, No.3, pp.71-77(2000).
  23. K.L. Cashdollar et al., "Flammability of Methane, Propane, and Hydrogen Gases", J. of Loss Prevention in the Process Industries, Vol.13, pp.327-340(2000). https://doi.org/10.1016/S0950-4230(99)00037-6
  24. Kirk-Othmer Encyclopedia of Chemical Technology, 3rd ed., John Wiley and Sons Inc.(1978).
  25. Aldrich Catalog of fine Chemicals, Aldrich Chemical Co., Inc., Milwaukee, Wisconsin(1986-1987).
  26. C.J. Hilado and S.W. Clark, "Autoignition Temperature of Organic Chemicals", Chemical Engineering, Vol.4, pp.75-80(1972).
  27. M. Sheldon, "Understanding Auto-ignition Temperature", Fire Engineering J., June, pp.27-32(1984).
  28. J. Gmehing, U. Onken, and W. Arlt, "Vapor-Liquid Equilibrium Data Collection", DECHEMA(1980).
  29. A.E. Cote and J.L. linville, "Fire Protection Handbook", 4th, ed. NFPA, Quncy, Massachusette(2002).
  30. N.N. Semenov, "Some Problems in Chemical Kinetics and Reactivity, Vol.2", Princeton University Press, Princeton, N.J.(1959).