자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension-

  • 서승석 (인제대학교 의과대학 부산백병원 정형외과학교실) ;
  • 김창완 (인제대학교 의과대학 부산백병원 정형외과학교실) ;
  • 김진석 (인제대학교 의과대학 부산백병원 정형외과학교실) ;
  • 최상영 (인제대학교 의과대학 부산백병원 정형외과학교실)
  • Seo, Seung-Suk (Department of Orthopedic Surgery, College of Medicine, Inje University, Busan Paik Hospital) ;
  • Kim, Chang-Wan (Department of Orthopedic Surgery, College of Medicine, Inje University, Busan Paik Hospital) ;
  • Kim, Jin-Seok (Department of Orthopedic Surgery, College of Medicine, Inje University, Busan Paik Hospital) ;
  • Choi, Sang-Yeong (Department of Orthopedic Surgery, College of Medicine, Inje University, Busan Paik Hospital)
  • 발행 : 2011.03.31

초록

목적: 자가 슬괵건을 이용한 전방 십자 인대 재건술에서 Cross pin 및 Graft Tensioner를 이용한 수술의 단기 추시 결과를 보고하고 조기 경험에서 발견된 수술 술기상의 문제점과 그 해결방안을 모색하고자 한다. 대상 및 방법: 2008년 1월부터 2009년 3월까지 자가 슬괵건을 이용한 전방 십자인대 재건술 후 최소 18개월이상 추시가 가능하였던 35예를 대상으로 하였다. 이식건의 대퇴골측 고정을 위해 Cross pin을, 경골측의 고정을 위해 Intrafix와 Post-tie를 사용하였다. 이식건은 Graft Tensioner을 이용하여 80N의 힘으로 고정하였다. 결과는 임상적, 방사선학적 결과와 합병증으로 평가하였다. 결과: IKDC 주관적 점수 및 Lysholm 점수는 술 후 89.1점 및 91.4점로 호전되었으며 축이동 검사 및 One-leg hop 검사도 술후 양호한 소견을 보였다. KT-1000 관절계 검사 및 Telos 부하 방사선 검사상 최종 추시시 건측에 비해 평균 $2.8{\pm}1.6$ mm, $2.6{\pm}1.3$ mm로 호전을 보였으며 대퇴골 터널은 평균 $2.3{\pm}1.1$ mm로 확장되었다. 수술 술기상 문제점으로 대퇴골 터널과 횡고정 터널의 불일치, 대퇴골 터널과 Graft Harness의 길이 불일치 그리고 연부 조직 자극이 관찰되었다. 결론: Cross pin 및 Graft Tensioner를 이용한 전방 십자인대 재건술은 단기 추시 상 좋은 안정성을 보여주는 수술 방법 중의 하나로 사료된다. 그러나 술기상 문제로 대퇴 터널-cross pin 불일치를 줄이기 위해 대퇴 터널을 짧게 만들거나 cross pin 터널을 피질골에 가능한 수직으로 만들어야 하며 대퇴 터널 형성시 위치 막대를 3 mm가량 더 진행시켜야 대퇴 터널-graft harness 불일치를 줄일 수 있을 것으로 생각된다.

Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.