References
- Santiago RC, De Paula FO, Fraga MR, et al. : Correlation between miniscrew stability and bone mineral density in orthodontic patients. Am J Orthod Dentofacial Orthop, 136:243-250, 2009. https://doi.org/10.1016/j.ajodo.2007.08.031
- Park HS, Jeong SH, Kwon OH : Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop, 130:18-25, 2006. https://doi.org/10.1016/j.ajodo.2004.11.032
- Salmoria KK, Tanaka OM, Guariza-Filho O, et al. : Insertional torque and axial pull-out strength of mini-implants in mandibles of dogs. Am J Orthod Dentofacial Orthop, 133:790-790, 2008.
- Florvaag B, Kneuertz P, Lazar F, et al. : Biomechanical properties of Orthodontic Miniscrews. An in-vitro study. J Orofac Orthop, 71:53-67, 2010. https://doi.org/10.1007/s00056-010-9933-y
- Reicheneder C, Rottner K, Bokan I, et al. : Mechanical loading of orthodontic miniscrews-significance and problems : an experimental study. Biomed Tech, 53:242-245, 2008. https://doi.org/10.1515/BMT.2008.038
- Brettin BT, Grosland NM, Qian F, et al. : Bicortical vs monocortical orthodontic skeletal anchorage. Am J Orthod Dentofacial Orthop, 134:625-635, 2008. https://doi.org/10.1016/j.ajodo.2007.01.031
- Miyawaki S, Koyama I, Inoue M, et al. : Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop, 124:373-378, 2003. https://doi.org/10.1016/S0889-5406(03)00565-1
- Fritz U, Ehmer A, Diedrich P : Clinical suitability of titanium microscrews for orthodontic anchorage-preliminary experiences. J Orofac Orthop, 65:410-418, 2004.
- Cheng SJ, Tseng IY, Lee JJ, Kok SH : A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants, 19:100-106, 2004.
- Cha JY, Takano-Yamamoto T, Hwang CJ : The Effect of Miniscrew Taper Morphology on Insertion and Removal Torque in Dogs. Int J Oral Maxillofac Implants, 25:777-783, 2010.
- Lim SA, Cha JY, Hwang CJ : Insertion Torque of Orthodontic Miniscrews According to Changes in Shape, Diameter and Length. Angle Orthod, 78: 234-240, 2008. https://doi.org/10.2319/121206-507.1
- Papadopoulos MA, Tarawneh F : The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 103:6-15, 2007. https://doi.org/10.1016/S1079-2104(07)00249-1
- Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N. : Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res, 17:109-114, 2006. https://doi.org/10.1111/j.1600-0501.2005.01211.x
- Kim JW, Cho IS, Lee SJ, et al. : Mechanical analysis of the taper shape and length of orthodontic mini-implant for initial stability. Korean J Orthod, 36:55-62, 2006.
- Chen Y, Kyung HM, Gao L, et al. : Mechanical properties of self-drilling orthodontic micro-implants with different diameters. Angle Orthod, 80:821-827, 2010. https://doi.org/10.2319/103009-607.1
- Suzuki EY, Suzuki B, Aramrattana A, et al. : Assessment of miniscrew implant stability by resonance frequency analysis : a study in human cadavers. J Oral Maxillofac Surg, 68:2682-2689, 2010. https://doi.org/10.1016/j.joms.2010.05.083
- 임수민, 양연미, 김재곤 등 : 혼합치열기의 miniscrew를 이용한 교정치료. 대한소아치과학회지, 35:367-375, 2008.
- Wilmes B, Rademacher C, Olthoff G, Drescher D : Parameters Affecting Primary Stability of Orthodontic Mini-implants. J Orofac Orthop, 67: 162-174, 2006. https://doi.org/10.1007/s00056-006-0611-z
- Swasty D, Lee JS, Huang JC, et al. : Anthropometric analysis of the human mandibular cortical bone as assessed by cone-beam computed tomography. J Oral Maxillofac Surg, 67:491-500, 2009. https://doi.org/10.1016/j.joms.2008.06.089
- 백병주, 김미라, 노용관 등 : 아동 및 청소년기의 하악각부피질골 두께에 관한 방사선학적 연구. 대한소아치과학회지, 25:225-233, 1998.
- Motoyoshi M, Yoshida T, Ono A, Shimizu N : Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants. 22:779-784, 2007.
- Maki K, Miller A, Okano T, Shibasaki Y : Changes in cortical bone mineralization in the developing mandible : a three-dimensional quantitative computed tomography study. J Bone Miner Res, 15: 700-709, 2000.
- Wang Z, Zhao Z, Xue J, et al. : Pullout strength of miniscrews placed in anterior mandibles of adult and adolescent dogs : A microcomputed tomographic analysis. Am J Orthod Dentofacial Orthop, 137:100- 107, 2010. https://doi.org/10.1016/j.ajodo.2008.01.025
- Homolka P, Beer A, Birkfellner W, et al. : Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles : pilot study. Radiology, 224:247-252, 2002. https://doi.org/10.1148/radiol.2241010948
- 임종원, 김왕식, 김일규 등 : 교정용 미니스크류 식립 시 스크류의 길이, 직경 및 피질골 두께에 따른 응력 분포에 관한 3차원 유한요소법적 연구. 대한치과교정학회지, 33: 11-20, 2003.
- Motoyoshi M, Uemura M, Ono A, et al. : Factors affecting the long-term stability of orthodontic miniimplants. Am J Orthod Dentofacial Orthop, 137: 588.e1-5, 2010. https://doi.org/10.1016/j.ajodo.2009.05.019