DOI QR코드

DOI QR Code

A Study on the Reduction of Cogging Force of Stationary Discontinuous Armature Linear Synchronous Motor Using Auxiliary Teeth

  • Kim, Yong-Jae (Dept. of Electrical Engineering, Chosun University) ;
  • Lee, Kyu-Myung (Dept. of Electrical Engineering, Chosun University) ;
  • Watada, Masaya (Dept. of Biomedical Engineering, Tokyo City University)
  • Received : 2011.06.13
  • Accepted : 2011.07.04
  • Published : 2011.09.30

Abstract

The stationary discontinuous armatures that are used in permanent magnet linear synchronous motors (PM-LSMs) have been proposed as a driving source for transportation systems. However, the stationary discontinuous armature PM-LSM contains the outlet edges which always exist as a result of the discontinuous arrangement of the armature. For this reason, the high alteration of the outlet edge cogging force produced between the armature's core and the mover's permanent magnet when a mover passes the boundary between the armature's installation part and non-installation part has been indicated as a problem. Therefore, we have examined the outlet edge cogging force by installing the auxiliary teeth at the armature's outlet edge in order to minimize the outlet edge cogging force generated when the armature is arranged discontinuously. Moreover, we obtained the calculation by analyzing the shape of the auxiliary teeth in which the outlet edge cogging force is minimized the most.

Keywords

References

  1. R. Akmese and J. F. Eastham, IEEE Trans. Magn. 28, 3042 (1992). https://doi.org/10.1109/20.179711
  2. M. Sanada, S. Morimoto, and Y. Takeda, IEEE Trans. Industry Appl. 33, 966 (1997). https://doi.org/10.1109/28.605738
  3. J. Chang, J. Kim, D. Kang, and D. Bang, J. Magnetics 15, 64 (2010). https://doi.org/10.4283/JMAG.2010.15.2.064
  4. Y. Kim and S. Jung, J. Magnetics 14, 47 (2009). https://doi.org/10.4283/JMAG.2009.14.1.047
  5. Y. Kim, H. Dohmeki, and D. Ebihara, IET Electric Power Appl. 153, 585 (2006). https://doi.org/10.1049/ip-epa:20050548

Cited by

  1. End Edge Characteristics of the Stationary Discontinuous Armature PM-LSM by Installing the Double-Auxiliary Teeth vol.416-417, pp.1662-7482, 2013, https://doi.org/10.4028/www.scientific.net/AMM.416-417.339