DOI QR코드

DOI QR Code

The Development of 20 mm Test Barrel with Replaceable Powder Chamber Type

약실교환방식의 20 mm 시험용 총열 개발

  • Received : 2011.04.25
  • Accepted : 2011.07.08
  • Published : 2011.08.05

Abstract

A new smooth bore test barrel was developed to be used in sensitivity assessment test for explosives and fragment impact test. The bore diameter of the barrel is 20 mm, and the powder chamber is designed to be replaceable with the 12.7 mm, 20 mm and 30 mm type chamber. The test results showed the wide range of fragment velocity from 400 to 2000 m/s, included the fragment velocity requirement of the fragment impact test(alternate procedure #1) in MIL-STD-2105B. The stability of the bullet trajectory was checked by test shots and the structural safety of the system has been confirmed through the stress analysis and the interior ballistics analysis of the barrel.

Keywords

References

  1. Department of Defense, MIL-SPEC-2105B, Military Standard:Hazard Assessment Tests for Non-Nuclear Munitions(AMSC N6037), Indian Head, MD, NSWC, 1994.
  2. 함덕순, 이진성, "파편충격시험 기법개발", 국방 과학연구소, 1999.
  3. O. K. Heiney, "Engineering Interior Ballistics of Closed Breech Guns", AFATL-TR-189, 1973.
  4. 문성기, 장순남, 이창형, 정해두, 이영철, 김근영, 손병선, "50MM 활강시험포의 탄도학적 특성분석 및 긴 관통자의 축소모델 시험평가 기법연구", 국방과학연구소, 1993.
  5. Steven L. Lightsey, David C. Mann, "A Precision Launch Technique for Insensitive Munitions Fragment Impact Testing", Denver Research Inst., CO., 1998.