DOI QR코드

DOI QR Code

Dialysis in double-pass cross-flow rectangular membrane modules with external recycle for improved performance

  • Yeh, Ho-Ming (Energy and Opto-Electronic Materials Research Center,Department of Chemical and Materials Engineering, Tamkang University Tamsui)
  • 투고 : 2010.04.26
  • 심사 : 2011.04.04
  • 발행 : 2011.04.25

초록

The predicting equations for mass transfer rate in cross-flow rectangular dialyzers with double flow and recycle, have been derived by mass balances. The recycling operation has two conflicting effects. One is the desirable effect of the increase in fluid velocity, resulting in an increased mass transfer coefficient. The other is the undesirable effect of the reduction in concentration difference due to remixing, resulting in decreased mass-transfer driving force. In contrast a single-pass device without recycling, considerable improvement in mass transfer is achieved if the cross-flow rectangular dialyzer of same size is operated with double pass and external recycling. It is concluded that recycle can enhance mass transfer, especially for larger reflux ratio.

키워드

참고문헌

  1. Geankoplis, C.J. (1983), "Transport processes and unit operations", yn and Bacon, Inc, Massachustte, 394.
  2. Kessler, S.B. and Klein, E. (1992), "Part IV: Dialysis, Chapter 12: Theory", Membrane Handbook, 167-185, W.S.W. Ho and K.K. Sirkar, Ed. Chapman and Hall, New York.
  3. Mulder, M. (1996), Basic Principle of Membrane Technology, 2nd ed., 358, Kluwer, Dordrecht, The Netherlands.
  4. Narebska, A. and Staniszewski, M. (2008), "Separation of carboxylic acids from carboxylates by diffusion dialysis", Sep. Sci. Technol., 43(3), 490-501. https://doi.org/10.1080/01496390701787388
  5. Oh, S.J., Moon, S.H. and Davis, T. (2000), "Effect of metal ions on diffusion dialysis of inorganic acids", J. Membrane Sci., 169(1), 95-105. https://doi.org/10.1016/S0376-7388(99)00333-6
  6. Palaty, Z. and Zakova, A. (2007) "Separation of HCl+$NiCl_{2}$ mixture by diffusion dialysis", Sep. Sci. Technol., 49(9), 1965-1983.
  7. Palaty, Z., Zakova, A. and Prchal, P. (2007), "Continuous dialysis of carboxylic acids. permeability of neosepta- AMH membrane", Desalination, 216(1-3), 345-355. https://doi.org/10.1016/j.desal.2006.09.029
  8. Palaty, Z. and Bendova, (2010), "Permeability of anion-exchange membrane for $Cl^{-}$ ions. Dialysis of hydrochloride acid in the presence of nickel chloride", Membrane Water Treat., 1(1), 39-47. https://doi.org/10.12989/mwt.2010.1.1.039
  9. Poter, M.C. (1990), "Handbook of Industrial Membrane Technology", Noyes Publications, New Jersey, pp.1-3.
  10. Tang, J.J., Zhou, K.G. and Zhang, Q.X. (2006), "Sulfuric acid recovery from rare earth sulfate solutions by diffusion dialysis", T. Nonfer. Metal Soc., 16(4), 951-955. https://doi.org/10.1016/S1003-6326(06)60358-0
  11. Xu, T.W. and Yang, W.H. (2003), "Industrial recovery of mixed acid (HF+$HNO_{3}$) from the titanium spent leaching solution by diffusion dialysis with a new series of anion-exchange membranes", J. Membrane Sci., 220(1-2), 89-95. https://doi.org/10.1016/S0376-7388(03)00218-7
  12. Xu, T.W. and Yang, W.H. (2004), "Tuning the diffusion dialysis performance by surface cross-linking of PPO anion-exchange membrane. Simultaneous recovery of sulfuric acid and nickel from electrolysis spent liquor of relatively low acid concentration", J. Hazard Mater., 109(1-3), 157-164. https://doi.org/10.1016/j.jhazmat.2004.03.016
  13. Yeh, H.M., Cheng, T.W. and Chen, Y.J. (1997), "Analysis of dialysis couple with ultrafiltration in cross-flow membrane modules", J. Membrane Sci., 134(2), 151-162. https://doi.org/10.1016/S0376-7388(97)00127-0
  14. Yeh, H.M. and Hsu, Y.S. (1999),"Analysis of membrane extraction through rectangular mass exchanger", Chem. Eng. Sci., 54, 897-908. https://doi.org/10.1016/S0009-2509(98)00272-3
  15. Yeh, H.M., Cheng, T.W. and Chen, Y.J. (2000), " Mass transfer for dialysis with ultrafiltration flux declined in cross-flow membrane modules", J. Chem. Eng. JPN, 33(3), 440-448. https://doi.org/10.1252/jcej.33.440
  16. Yeh, H.M. and Chen, Y.K. (2000), "Membrane extraction through cross-flow rectangular modules", J. Membrane Sci., 170, 235-242. https://doi.org/10.1016/S0376-7388(99)00366-X
  17. Yeh, H.M. (2009), "Numerical analysis of mass transfer in double-pass parallel-plate dialyzers with external recycle", Computers Chem. Eng., 33, 815-821. https://doi.org/10.1016/j.compchemeng.2008.12.006
  18. Yeh, H.M., Cheng, T.W. and Chen, K.H. (2010), "Dialysis in parallel-flow rectangular membrane modules with external reflux for improved performance", Membrane Water Treatment, 1(2), 159-169. https://doi.org/10.12989/mwt.2010.1.2.159