Abstract

Evapotranspiration is one of the important elements related water cycle and there is many kind of measurement method of evapotranspiration today. This study developed mini lysimeter for the purpose of direct measurement of evapotranspiration and installed on 5th, July, 2010 at the field of MRI which located at Tsukuba, Ibaraki, Japan for continuous measurement and understand relation between evapotranspiration and meteorological elements expecially radiation elements. And compared the evapotranspiration data of lysimeter with Bowen Ratio Method. The result of this study is as follows; There is high related with solar radiation and evapotranspiration with $R^2$=0.947. and 46 % of solar radiation converted into evapotranspiration during clear 5 days. In net radiation also highly related with evapotranspiration, we can derive evapotranspiration is mainly controlled by radiation energy in clear days. From the 104 days data, there is only 9 % difference between Bowen Ratio Method and evapotranspiration of lysimeter which was developed from this study is very useful to estimate evapotranspiration at field site with simple and high accuracy. High accuracy and resolution measurement of evapotranspiration by lysimeter can give a chance further study of meteorological phenomena of on ground expecially in night time condensation which means abnormal energy flow.

Keywords

References

  1. 강민석, 권효정, 임종환, 김준, 2009, 광릉 활엽수림과 침엽수림에서 에디공분산으로 관측한 하부 군락의 증발산, 한국농림기상학회지, 11(4), 233-246. https://doi.org/10.5532/KJAFM.2009.11.4.233
  2. 권효정, 이정훈, 이연길, 이진원, 정성원, 김준, 2009, 설마천 유역의 혼효림에서 관측된 증발산의 계절 변화, 한국농림기상학회지, 11(1), 39-47. https://doi.org/10.5532/KJAFM.2009.11.1.039
  3. 양성일, 강동환, 권병혁, 김병우, 2010, 해안도시 지역에서 증발산량 산정에 토지이용도와 기상인자의 영향성, 한국환경과학회지, 19(3), 295-304. https://doi.org/10.5322/JES.2010.19.3.295
  4. 이부용, 2001, 대형증발계용 매시간 증발 기록계 개발에 관한 연구, 한국환경과학회지, 10(5), 323-327.
  5. 진병화, 황수진, 1995, 증발량 추정을 위한 지표면 가용 수분 계수, 한국환경과학회지, 4(5), 427-435.
  6. 한진수, 이부용, 2005, 해남 농경지에서의 자유수면 증발 관측과 해석, 한국농림기상학회지, 7(1), 91-97.
  7. http://maps.google.co.kr/maps.
  8. Michela, C., Stefano, P., Haria, F., Eugenio, M., Cesare, I., 2009, Evaluation of an open portable chamber system for measuring cover crop water use in a vineyard and comparison with a mini-lysimeter approach, Agricultural and Forest Meteorology, 149, 1975-1982. https://doi.org/10.1016/j.agrformet.2009.07.005
  9. Prueger, J. H., Hatfield, J. L., Aase, J. K., Pikul Jr., J. L., 1997, Bowen-Ratio comparisons with lysimeter evapotranspiration, Agronomy Journal, 89(5), 730-736. https://doi.org/10.2134/agronj1997.00021962008900050004x
  10. Rana, G., Katerji, N., 2000, Measurement and estimation of actual evapotranspiration in the field under Mediterranean climate: a review, European Journal of Agronomy, 13, 123-153.