DOI QR코드

DOI QR Code

Development of a Single-Joint Optical Torque Sensor with One Body Structure

일체형 구조를 갖는 1축 광학 토크 센서 개발

  • Received : 2010.11.15
  • Accepted : 2010.12.20
  • Published : 2011.03.01

Abstract

This paper proposes a single-joint optical torque sensor with one body structure. Conventional optical torque sensors consist of three parts, two plates and an elastic structure. They have slightly slipping problem between plates and elastic structure due to the manufacturing tolerance. Since the order of measurement range of optical sensor is about ten micrometers, the slipping problem causes large measurement error, especially in the case of vibrational or high speed plant. This problem does not occur in the proposed design due to the one body structure. The proposed sensor has advantage of low cost, light weight, and small size. And it is easy to design and manufacture. Simulation works that analysis of stress and strain are performed accurately. To demonstrate the performance of proposed sensor, experiments were implemented to compare with a commercial force/torque sensor (ATI Mini45).

Keywords

References

  1. D. E. Whitney, "Historical perspective and state of the art in robot force control," The International Journal of Robotics Research, vol. 6, no. 1, pp. 3-14, Mar. 1987. https://doi.org/10.1177/027836498700600101
  2. N. Horgan, "Impedance control: An approach to manipulation," Proc. of American Control Conference, San Diego, CA, USA, pp. 304-313, Jun. 1984.
  3. T. Wimbock, C. Ott, and G. Hirzinger, "Impedance behaviors for two-handed manipulation: Design and experiments," Proc. of IEEE International Conference on Robotics and Automation, Roma, Italy, pp. 4182-4189, Apr. 2007. https://doi.org/10.1109/ROBOT.2007.364122
  4. I. W. Park, J. Y. Kim, J. Lee, and J. H. Oh, "Mechanical design of humanoid robot platform KHR-3: HUBO," Proc. of 5th IEEE- RAS Int. Conf. on Humanoid Robots, pp. 321-326, 2005. https://doi.org/10.1109/ICHR.2005.1573587
  5. D. Vischer and O. Khatib, "Design and development of high-performance torque-controlled joints," IEEE Transactions on Robotics and Automation, vol. 11, no. 4, pp. 537-544, Aug. 1995 https://doi.org/10.1109/70.406938
  6. D. Tsetserukou, R. Tadakuma, H. Kajimoto, and S. Tachi, "Optical torque sensors for implementation of local impedance control of the arm of humanoid robot," Proc. of the 2006 IEEE International Conference on Robotics and Automation, Orlando, Florida, pp. 1674-1679, May 2006. https://doi.org/10.1109/ROBOT.2006.1641947
  7. F. Aghili, M. Buehler, and J. M. Hollerbach, "Design of a hollow hexaform torque sensor for robot joints," The International Journal of Robotics Research, vol. 20, no. 12, pp. 967-976, Dec. 2001. https://doi.org/10.1177/02783640122068227
  8. http://www.alldatasheet.com, "CNA1311K".
  9. http://www.ati-ia.com/products/ft/sensors.aspx, "Mini 45".