참고문헌
- Kwon OY. Artifact in Electroencephalography. Korean J Clin Neurophysiol 2003;5:157-169.
- Niedermeyer E, Lopes da Silva FH. Electroencephalography: basic principles, clinical applications, and related fields. Baltimore: Williams & Wilkins 1999;110-121.
- Huigen E, Peper A, Grimbergen C. Investigation into the origin of the noise of surface electrodes. Med Biol Eng Comput 2002;40:332-338. https://doi.org/10.1007/BF02344216
- Carter SJ, Linker CJ, Turkle-Huslig T, Howard LL. Comparison of impedance at the microelectrode-saline and microelectrodeculture medium interface. IEEE Trans Biomed Eng 1992;39:1123-1129. https://doi.org/10.1109/10.168691
- Rosell J, Colominas J, Riu P, Pallas-Areny R, Webster JG. Skin impedance from 1 Hz to 1 MHz. IEEE Trans Biomed Eng 1988;35:649-651. https://doi.org/10.1109/10.4599
- Padmadinata FZ, Veerhoek JJ, Vandijk GJA, Huijsing JH. Microelectronic skin electrode. Sensor Actuat B-Chem 1990;1:491-494. https://doi.org/10.1016/0925-4005(90)80257-Z
- Webster JG, Clark JW. Medical instrumentation: application and design. Boston: Houghton Mifflin 1992;248-290.
- Handbook of chemistry and physics. Cleveland, Ohio: CRC Press, 1974-1975.
- Ferree TC, Luu P, Russell GS, Tucker DM. Scalp electrode impedance, infection risk, and EEG data quality. Clin Neurophysiol 2001;112:536-544. https://doi.org/10.1016/S1388-2457(00)00533-2
- Nishimura S, Tomita Y, Horiuchi T. Clinical-application of an active electrode using an operational-amplifier. IEEE Trans Biomed Eng 1992;39:1096-1099. https://doi.org/10.1109/10.161342
- Searle A, Kirkup L. A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol Meas 2000;21:271-283. https://doi.org/10.1088/0967-3334/21/2/307
- Bergey GE, Squires RD, Sipple WC. Electrocardiogram recording with pasteless electrodes. IEEE Trans Biomed Eng 1971;BME-18:206-211. https://doi.org/10.1109/TBME.1971.4502833
- Mclaughlin JA, Mcadams ET, Anderson JM. Novel dry electrode ECG sensor system. Proceedings of the 16th annual international conference: IEEE EMBS 1994;804-804.
- Geddes LA, Steinberg R, Wise G. Dry electrodes and holder for electro-oculography. Med Biol Eng 1973;11:69-72. https://doi.org/10.1007/BF02477298
- Fujisawa M, Uchida K, Yamada Y, Ishibashi K. Surface electromyographic electrode pair with built-in buffer-amplifiers. J Prosthet Dent 1990;63:350-352. https://doi.org/10.1016/0022-3913(90)90210-4
- Degen T, Jackel H. Enhancing interference rejection of preamplified electrodes by automated gain adaption. IEEE Trans Biomed Eng 2004;51:2031-2039. https://doi.org/10.1109/TBME.2004.834296
- Valverde E, Arini P, Bertran G, Biagetti M, Quinteiro R. Effect of electrode impedance in improved buffer amplifier for bioelectric recordings. J Med Eng Technol 2004;28:217-222. https://doi.org/10.1080/03091900410001662323
- Taheri BA, Knight RT, Smith RL. A dry electrode for EEG recording. Electroencephalogr Clin Neurophysiol 1994;90:376-383. https://doi.org/10.1016/0013-4694(94)90053-1
- TLC2652, TLC2652A, TLC2652Y Advanced LinCMOS PRECISION CHOPPER-STABILIZED OPERATIONAL AMPLIFIERS. Texas Instruments, 2001.
- Hsieh KC, Gray PR, Senderowicz D, Messerschmitt DG. A low-noise chopper-stabilized differential switched-capacitor filtering technique. IEEE J Solid-St Circ 1981;16:708-715. https://doi.org/10.1109/JSSC.1981.1051666
- Hanasusanto GA, Yuanjin Z. A chopper stabilized preamplifier for biomedical signal acquisition. International symposium on integrated circuits: IEEE 2007;200-203.
- Miller HA, Harrison DC. Biomedical electrode technology: theory and practice. New York: Academic Press, 1974.
- Ko D, Lee GT, Lee EJ, Lee SH, Kim BJ. Development of PDMS and silver ball based dry-type flexible EEG electrode for long-term EEG recording. 13th Conference of the Korean Society of Clinical Neurophysiology. Korean J Clin Neurophysiol 2010;12:114-114.
- Ruffini G, Dunne S, Farres E, Cester I, Watts PCP, Silva SRP, et al. ENOBIO dry electrophysiology electrode; first human trial plus wireless electrode system. 2007 Annual International Conference: IEEE EMBS 2007;6690-6694.
- Casson A, Yates D, Smith S, Duncan J, Rodriguez-Villegas E. Wearable electroencephalography. IEEE Eng Med Biol Mag, IEEE EMBS 2010;29:44-56.
- Shin JH, Seo EM, The trends of BCI based Entertainic, Technology, The Magazine of the IEEK, IEEK 2007;34:71-82.