Abstract
In this study, titanium abutments and zirconia abutments were connected to each implant in external type implants. After that they were loaded 10000 times with 20Kg as occlusal force. The surface changes of external hexgon part and platform were observed in FESEM image. Viker's hardness of an implant, a titanium abutment and a zirconia abutment were measured respectively. 1. Viker's hardness of an implants, a titanium abutment and a zirconia abutment was $309.80{\pm}11.78$ HV, $318.40{\pm}11.82$ HV, and $1495.30{\pm}16.21$ HV respectively. There was no statistical significance between an implant and a titanium abutment (P>0.05, Anova). However, there was statistical significance between an implant and a zirconia abutment(P<0.05, Anova). 2. The wear was observed at the joint of implant and abutment in both a titanium abutment group and a zirconia abutment group after loading 10,000 times. The zirconia abutment showed more remarkable wear than the titanium one. In conclusion, the wear of external hexagon and platform was much more notable in a zirconia abutment group than a titanium one. It was suggested that it could result from the difference of surface hardness between titanium and zirconia. The wear of junction between an implant and a zirconia abutment becomes more severe, the connection of an implant and an abutment is much more unfit. This is likely to cause loosening and fracture of the abutment screw. so it is considered that the possibility of implant supra-structure failure can be increased.
본 연구는 외부연결방식(external type)의 임프란트에서 기존의 타이타늄 지대주와 지르코니아 지대주를 각각의 임플란트와 연결하여 하중을 가한 후 임플란트 외부육각기둥(external hexgon)부분 및 platform 표면변화를 FESEM 상으로 관찰하고, 임프란트와 타이타늄 지대주 및 지르코니아 지대주의 Viker's 경도를 측정하였다. 1. 임프란트, 타이타늄 지대주 및 지르코니아 지대주의 Viker's 경도는 각각 평균 $309.80{\pm}11.78$ HV, $318.40{\pm}11.82$ HV, $1495.30{\pm}16.21$ HV였다. 임프란트와 타이타늄 지대주 사이에는 통계학적으로 유의성이 존재하지 않았지만(P>0.05, Anova), 임프란트와 지르코니아 사이에는 통계학적으로 유의성이 관찰되었다(P<0.05, Anova). 2. 10,000번 하중을 가한 후 임플란트 표면변화 관찰에서 타이타늄 지대주 그룹과 지르코니아 지대주 그룹 모두에서 마모가 관찰 되었으며, 지르코니아 지대주에서 보다 현저한 마모양상을 나타내었다. 본 연구에서 표면경도의 차이로 인하여 타이타늄 지대주를 사용할 때보다 지르코니아 지대주를 사용한 경우 임플란트의 external hexagon부분 및 플랫폼의 마모도가 현저하였다.