DOI QR코드

DOI QR Code

분수에서 생성되는 물입자의 확산과 냉각효과의 범위 예측

A Study on Predicting the Range of Cooling Effect and the Diffusion of Water Particles that are Generated from a Fountain

  • Lee, Sang-Deug (Department of Environmental Engineering, Mokpo National University)
  • 투고 : 2010.08.03
  • 심사 : 2011.04.27
  • 발행 : 2011.07.31

초록

This research was done to clarify the cooling effect of water particles generated from a fountain. This effect is a one way to control the heat island effect of big cities. The result of this research was drawn by setting the jets of water in a certain height, and then studying the diffusion of water particles, which is affected by the size of the particles and the wind speed, and the cooling effect caused by the diffusion. 1) When a diameter of a water drop was 500 ${\mu}m$ and the wind speed was 2.0 to 6.0 m/sec, the water drop diffused 75 to 190m, and the water vapor spread over 175 to 440 m. As a result, there was more than $0.5^{\circ}C$ of cooling effect on the temperature in the atmosphere 130 to 330m around the water fountain. 2) When a diameter of a water drop was 750 ${\mu}m$ and the wind speed was 2.0 to 6.0 m/sec, the water drop diffused 65 to 150 m, and the water vapor spread over 160 to 405 m. Moreover, there was more than $0.5^{\circ}C$ of cooling effect on the temperature in the atmosphere 110 to 275 m around the water fountain. 3) After studying on the relationship between the diameter of water drop and the wind speed, and the diffusion of water particles and the range of the atmosphere that was cooled, a result could be drawn from the research that the smaller the diameter of the water vapor gets and the faster the wind speed becomes, the wider the water particles diffuse and the cooler the atmosphere around the fountain becomes. 4) This research further extrapolates that when the ordinary water(tap water, water from river and stream) is used in a fountain, the cooling effect of the air near the fountain can be approached similarly. If the seawater is used in a fountain, there is to be more to concern not only on cooling effect on the air, but also on other effects on surrounding environment generated by the salt in seawater.

키워드

참고문헌

  1. 조세환, 1989, 경관 연출을 위한 Water Design, 환경과 조경, 제31호.
  2. 김영인, 김민중, 김정수, 홍형순, 장태현, 2001, 사직 분수대 설계, 한국조경학회지, 29(4), 75-81.
  3. 이승희, 2004, 실내 도제분수에 관한 연구, 석사학위 논문, 숙명여자대학교 디자인대학원.
  4. 허현철, 2005, 바닥 분수의 이용 후 평가, 석사학위 논문, 진주산업대학교 산업대학원.
  5. 유민준, 노창환, 이인권, 권대현, 2007, 음악 분수 시뮬레이션 시스템, 한국컴퓨터 그래픽스학회, 2007(0), 23-24.
  6. 이상득, 1998, 냉각효과를 고려한 2차원 분수 모델의 개발, 대기환경학회지, 20(10), 1345-1354.

피인용 문헌

  1. Risk Assessment of Escherichia coli Infection from Use of Interactive Waterscape Facilities vol.38, pp.1, 2012, https://doi.org/10.5668/JEHS.2012.38.1.073