Abstract
In this paper, the results of experimental analysis for the chemical composition and strengh verification of Bailey Panel Bridge have been presented. Some of main sections of bailey bridge colllected from military engineer troops were prepared for the chemical composition and strengh verification. The composition test and strength verification were conducted by using the optical microscope and Scanning Electron Microscope(SEM), Automatic Control Spark Emission Spectrometer(OBLF), X-ray Fluorescence Spectroscopy(XRF) and Instron measurement. The results showed that currently used sections of bailey bridge passed the strength verification and could be operated in drill of troops and battle fields.