References
- Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants.(I).Success criteria and epidemiology. Eur J Oral Sci. 1998; 106: 527-51. https://doi.org/10.1046/j.0909-8836..t01-2-.x
- Triplett RG, Frohberg U, Sykaras N, Woody RD. Implant materials, design, and surface topographies: their influence on osseointegration of dental implants. J Long Term Eff Med Implants. 2003; 13: 485-501.
- Sul YT, Johansson CB, Jeong Y, Albrektsson T. The electrochemical oxide growth behaviour on titanium in acid and alkaline electrolytes. Med Eng Phys. 2001; 23: 329-46. https://doi.org/10.1016/S1350-4533(01)00050-9
- Davis JE. Mechanisms of endoosseous integration. Int J Prothodont. 1998; 11: 391-401.
- Lausmaa J, Kasemo B, Rolander U, Bjursten LM, Ericson LE, Rosander L, Thomsen P. Preparation, surface spectroscopic and electron microscopic characterization of titanium implant materials. In: Ratner BD: Surface Characterization of Biomaterials. Amsterdam: Elsevier; 1988: 161-74.
- Kasemo B, Lausmaa J. Biomaterial and implant surfaces: a surface science approach. Int J Oral Maxillofac Implants. 1988; 3: 247-59.
- Sul YT, Johansson CB, Petronis S, Krozer A, Jeong Y, Wennerberg A, Albrektsson T. Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition. Biomaterials. 2002; 23: 491-501. https://doi.org/10.1016/S0142-9612(01)00131-4
- Larsson C, Emanuelsson L, Thomsen P, Ericson LE, Aronsson BO, Kasemo B, Lausmaa J. Bone response to surface-modified titanium implants-studies on the tissue response after one year to machined and electropolished implants with different oxide thicknesses. J Mater Sci Mater Med. 1997; 8: 721-9. https://doi.org/10.1023/A:1018548225899
- Ichikawa T, Hanawa T, Ukai H , Murakami K. Three-dimensional bone response to commercially pure titanium, hydroxyapatite, and calciumion- mixing titanium in rabbits. Int J Oral Maxillofac Implants. 2000; 15: 231-8.
- Fini M, Cigada A, Rondelli G, Chiesa R, Giardino R, Giavaresi G, Nicoli Aldini N, Torricelli P, Vicentini B. In vitro and in vivo behavior of Ca-and P-enriched anodized titanium. Biomaterials. 1999; 20: 1587-94. https://doi.org/10.1016/S0142-9612(99)00060-5
- Sul YT, Johansson CB, Jeong Y, Wennerberg A, Albrektsson T. Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides. Clin Oral Implants Res. 2002; 13: 252-9. https://doi.org/10.1034/j.1600-0501.2002.130304.x
- Albrektsson T, Johanson C, Lundgren AK, Sul YT, Gottlow J. Experimental studies on oxidized implants. A Histomorphometrical and biomechanical analysis. Appl Osseointegration Res. 2000; 1: 21-4.
- Gottlow J, Johansson C, Albrektsson T, Lundgren AK. Biomechanical and histologic evaluation of the TiUnite and Osseotite implant surfaces in rabbits after six weeks of healing. Appl Osseointegration Res. 2000; 1: 25-7.
- Li LH, Kong YM, Kim HW, Kim YW, Kim HE, Heo SJ, Koak JY. Improved biological performance of Ti implants due to surface modification by micro-arc oxidation. Biomaterials. 2004; 25: 2867-75. https://doi.org/10.1016/j.biomaterials.2003.09.048
- Donath K, Breuner G. A method for the study of undecalcified bones and teeth with attached soft tissues. the Säge-Schilff(sawing and grinding technique). J Oral Pathol. 1982; 11: 318-26. https://doi.org/10.1111/j.1600-0714.1982.tb00172.x
- Deporter D, Watson P, Pharoah M, Levy D, Todescan R. Five-to sixyear results of a porspective clinical trial using the ENDOPORE dental implant and a mandibular overdenture. Clin Oral Implants Res. 1999; 10: 95-102. https://doi.org/10.1034/j.1600-0501.1999.100203.x
- Buser D, Nydegger T, Oxland T, Cochran DL, Schenk RK, Hirt HP, Snétivy D, Nolte LP. Interface shear strength of titanium implants with a sandblasted and acid-etched surface: a biomechanical study in the maxilla of miniature pigs. J Biomed Mater Res. 1999; 45: 75-83. https://doi.org/10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO;2-P
- Li J, Hastings GW. Oxide ceramics: inert ceramic materials in medicine and dentistry. In: Black J, Hastings G: Handbook of biomaterial properties. 1st ed. London: Chapman & Hall; 1998: 340-54.
- Ishizawa H, Fujino M, Ogino M. Mechanical and histological investigation of hydrothermally treated and untreated anodic titanium oxide films containing Ca and P. J Biomed Mater Res. 1995; 29: 1459-68. https://doi.org/10.1002/jbm.820291118
- Larssons C. The interface between bone and implant with different surface oxide implants. Appl Osseointegration Res. 2000; 1: 9-14.
- Sul YT, Johnasson CB, Röser K, Albrektsson T. Qualitative and quantitavie observation of bone tissue reaction to anodized implants. Biomaterials. 2002; 23: 1809-17. https://doi.org/10.1016/S0142-9612(01)00307-6
- Sul YT, Johansson CB, Kang Y, Jeon DG, Albrektsson T. Bone reactions to oxidized titanium implants with electrochemical anion sulphuric acid and phosphoric acid incorporation. Clin Implant Dent Relat Res. 2002; 4: 78-87. https://doi.org/10.1111/j.1708-8208.2002.tb00156.x
- Rompen E, DaSilva D, Lundgren AK, Gottlow J, Sennerby L. Stability measurements of a double-threaded titanium implant design with turned or oxidized surfaces . An experimental resonance frequency analysis study in the dog mandible. Appl Osseointegration Res. 2000; 1: 18-20.
- Rasmusson L, Meredith N, Kahnberg KE, Sennerby L. Stability assessments and histology of titanium implants placed simultaneously with autogenous onlay bone in the rabbit tibia. Int J Oral Maxillofac Surg. 1998; 27: 229-35. https://doi.org/10.1016/S0901-5027(98)80019-2
- Glauser R, Portmann M, Ruhstaller P,Lundgren A, Hämmerle C, Gottlow J. Stability measurements of immediately loaded machined and oxidized implants in the posterior maxilla. A comparative clinical study using resonance frequency analysis. Appl Osseointegration Res. 2001; 2: 27-9.
- Robert WE. Bone physiology, metabolism and biomechanics in orthodontic practice. In: Graber TM, Vanasdall RJ Jr: Orthodonticscurrent principlesand techniques. St Louis: Mosby; 1994: 193-234.
- Roccuzzo M, Bunino M, Prioglio F, Bianchi SD. Early loading of sandblasted and acid etched(SLA) implants: a prospective split-mouth comparative study. Clin Oral Implants Res. 2001; 12: 572-8. https://doi.org/10.1034/j.1600-0501.2001.120604.x
- Dahlin C, Sennerby L, Lekholm U, Linde A, Nyman S. Generation of new bone around titanium implants using a membrane technique: an experimental study in rabbits. Int J Oral Maxillofac Implants. 1989; 4: 19-25.