DOI QR코드

DOI QR Code

A study on the microhardness and the marginal fitness of the various composite resins

수종의 복합레진에 대한 미세경도와 변연적합도 비교

  • Kim, So-Min (Dept. of Oral Health, Graduate School of Public Health & Social Welfare, Dankook University) ;
  • Cho, Ja-Won (Department of Preventive Dentistry, College of Dentistry, Dankook University) ;
  • Hwang, Kyung-Sook (Dept. of Dental Technology, Shinheung College University) ;
  • Kim, Wook-Tae (Dept. of Dental Technology, Shinheung College University) ;
  • Kang, You-Hwa (Dental Device Testing & Evaluation Center, College of Dentistry, Yonsei University) ;
  • Kim, Nam-Joong (Dept. of Dental Technology, Shinheung College University)
  • 김소민 (단국대학교 보건복지대학원 구강보건학과) ;
  • 조자원 (단국대학교 치과대학 예방치과학교실) ;
  • 황경숙 (신흥대학교 치기공학과) ;
  • 김욱태 (신흥대학교 치기공학과) ;
  • 강유화 (연세대학교 치과대학 치과의료기기시험평가센터) ;
  • 김남중 (신흥대학교 치기공학과)
  • Received : 2011.05.19
  • Accepted : 2011.06.24
  • Published : 2011.06.30

Abstract

Purpose: The author performed experiments on the microhardness and the marginal fitness of composite resins after polymerizing 4 kinds of composite resins on MOD standard specimens. Methods: For this study, in order to compare the microhardness and the marginal fitness of 4 kinds of composite resins. Results: The results are as follows. 1. In case of the microhardness, Tescera scored the highest among the four kinds of composite resins. 2. In case of the marginal fitness, Premise Indirect scored the highest. However, there was no statistically significant difference, all staying in clinically practical range. 3. Considering the above results, among the four kinds of composite resins, the author advises to use Tescera during teeth restoration which scored the highest in the micro- hardness. Conclusion: Conclusion: All of the composite marginal fitness were within the clinically useful range.

Keywords

References

  1. 김상배, 이광수. 가시광선과 플라즈마 광선에 의한 복합 레진 중합 시 미세누출과 미세경도에 관한 연구. J Korean Acad Pediatr Dent, 29(2), 180-188, 2002.
  2. 이백호. 치아 수복용 복합레진의 광중합 광원 종류에 따른 표면경도비교. 전남대학교 치의학전문대학원 치의학과 석사학위논문, 2010.
  3. 이종률, 김경남. 치과인의 필독 정선치과재료학. 한국퀸텐센스 출판사, 1995.
  4. 한동만, 황경숙. 응용관교의치기공학. 제1판, 명문출판사, 2010.
  5. Alvarez-Gayosso C, Barcelo-Santana F, Guerrero- Ibarra J, Saea-Espinola G, Canseco- Martinez MA. Calculation of contraction rates due to shrinkage in light-cured composites. Dent Mater, 20(3), 228-235, 2004. https://doi.org/10.1016/S0109-5641(03)00097-6
  6. Anke Schattenberg, Dana Lichtenberg, Elmar Stender, Brita Willerchausen, Claus-Peter Ernst. Mininal exposure time of different LED-curing devices. Dent Mater, 24, 1043-1049, 2008. https://doi.org/10.1016/j.dental.2007.12.001
  7. Assif D, Rimer Y, Aviv I. The flow of zinc phosphate cement under a full-coverage restoration and its effect on marginal adaptation according to the location of cement application. Quitessence International, 18, 765, 1987.
  8. Belser VC, MacEntee MI and Richter WA. Fit of three porcelain-fused-to-metal marginal design in vivo. A SEM study. J Prosthet Dent, 5(3), 24, 1985.
  9. Christensen GJ. Marginal fit of gold inlay casting. J Prosthet Dent, 13, 297, 1966.
  10. Donovan T, Prince J. An analisis of margin configuration for metal-ceramic crown. J prosthet Dent, 53, 153, 1985. https://doi.org/10.1016/0022-3913(85)90097-6
  11. Faucher RR, Nicholls JI. Distortion related to margin in porcelain-fused-to-metal restoration. J Prosthet Dent, 43, 149, 1980. https://doi.org/10.1016/0022-3913(80)90178-X
  12. Hung SH, Hung K, Eick JD, Chappell RP. Marginal fracture of porcelain-fused-to metal and two types of ceramic crown. J prosthet Dent, 63, 26, 1990. https://doi.org/10.1016/0022-3913(90)90260-J
  13. Jeneric/Pento Inc. Optec HSP laboratory technique manual. Wallingford, Conn, 1998.
  14. Mclean JW, Von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J, 131, 107, 1971. https://doi.org/10.1038/sj.bdj.4802708
  15. Moon BH, Yang JH, Lee SH, Chung HY. A study on the marginal fit of all-ceramic crown using ccd camera. J Kor Acad Prosthodont, 36, 273-292, 1998.
  16. Park SH, Krejci I, Lytz F. Operative Dentistry, 27, (30-37), 2002.
  17. Shinohara N, Minesaki Y, Mukoyoshi N, Moryyama, Jimi T. The effect of the cementing material on the strength of the all ceramic crown. J Jpn Prosthodont, 33, 416, 1989. https://doi.org/10.2186/jjps.33.416
  18. Shillinburg HT, Hobo S, Fisher DW. Porcelainfused- to-metal restoration. J Prosthet Dent, 29, 276, 1973. https://doi.org/10.1016/0022-3913(73)90007-3