DOI QR코드

DOI QR Code

Utilization of Image Analysis Technique for Characterization of Micro-Bubbles Generated by Polymeric Membrane Module

고분자 중공사막 모듈을 이용한 미세기포 발생과 이미지 분석기법을 이용한 기포 특성 파악

  • Kim, Jun-Young (Department of Semiconductor and Display Engineering, Hoseo University) ;
  • Chang, In-Soung (Department of Environmental Engineering, Hoseo University)
  • 김준영 (호서대학교 반도체 디스플레이 공학과) ;
  • 장인성 (호서대학교 환경공학과)
  • Received : 2010.10.27
  • Accepted : 2011.06.26
  • Published : 2011.06.30

Abstract

In this study, the polymeric membrane module is used as a diffuser and an image analysis technique based on visual information is applied to get bubble characteristics. The bubble size generated passed through polymeric membrane module was smaller from 30 to 64% than that of air stone, and bubble volume over 70% was ranged from 0.2 to 0.82 mm. But over 80% the bubbles from air stone diffuser ranged from 0.77 to 1.08 mm. The air stone and polymeric membrane module used as diffuser for a flotation system. The floc size inside the flotation reactor using air stone diffuser was bigger than that of the polymeric membrane module, which means that the micro-bubbles generated from polymeric membrane module could provide better opportunities for collisions between colloidal particles than those from air stone diffuser. Therefore, there is a possibility to apply the polymeric membrane module as a diffuser to increase the removal efficiency in the flotation process. Also, the image analysis technique used in this study could be applied as a useful analytical tool for acquisition of an information about the bubble characteristic.

본 연구에서는 고분자 중공사막 모듈을 산기 도구로 사용하여 미세 기포 발생을 도모하였고 영상정보를 기반으로 하는 이미지 분석 기법을 적용하여 발생한 기포 특성을 파악하고자 하였다. 기포의 이미지 분석 결과, 고분자 중공사막 모듈을 통해 수중에 분사된 기포는 산기석을 통한 기포보다 약 30~64% 작은 크기로 발생되는 것을 관찰하였고, 기포의 70% 이상이 0.2~0.82 mm 범위에 분포된 반면, 산기석의 경우는 0.77~1.08 mm의 범위에 속한 기포가 80% 이상이었다. 산기석과 고분자 중공사막모듈을 각각 기포발생 장치로 사용한 부상조를 운영하였을 때 반응조에 잔존하는 플록의 크기는 산기석을 이용했을 때가 고분자 중공사막 모듈의 경우보다 더 큰 것으로 나타났다. 이는 고분자 중공사막 모듈에 의해 발생한 미세기포가 충돌 효율의 증가 때문에 크기가 작은 콜로이드 입자들까지 응집/부상할 수 있는 기회를 제공하였기 때문이다. 따라서 부상공정에 고분자 중공사막모듈을 산기장치로 활용하였을 경우 응집부상 제거효율이 증가할 수 있는 가능성을 보였다. 또한 본 연구에서 사용한 이미지 분석기법은 제공된 영상정보를 기반으로 기포의 기초 특성들과 관련된 정보습득을 위한 분석도구로 활용될 수 있을 것으로 판단된다.

Keywords

References

  1. 이창한, 안대명, 김성수, 조석호, 안갑환, "DAF펌프를 이용한 실규모 용존공기부상 공정의 전처리 조건," 대한환경공학회지, 31(1), 58-63(2009).
  2. 박용호, 한무영, "DAF에서 기포크기의 영향," 상하수도 학회지, 17(4), 528-533(2003).
  3. 한무영, 김충일, 박성원, 김하룡, 이관우, 유해운, "DAF에서 맞춤형 기포크기 제조장치의 개발과 응용," 한국수처리학회지, 15(2), 13-23(2007).
  4. Han, M. Y., Kim, M. K. and Ahn, H. J., "Effects of surface sharge, micro-bubble size and particle size on removal efficiency of electro-flotation," Water Sci. Technol., 53(7), 127-132(2006). https://doi.org/10.2166/wst.2006.216
  5. 한무영, 김충일, 박성원, "플록과 기포의 크기가 DAF 공정의 효율에 미치는 영향," 한국수처리학회지, 15(1), 11-16 (2007).
  6. Lu, Y., Ding, Z., Liu, L., Wang, Z. and Ma, R., "The influence of bubble characteristics on the performance of submerged hollow fiber membrane module used in microfiltration," Sep. & Purif. Technol., 61, 89-95(2008). https://doi.org/10.1016/j.seppur.2007.09.019
  7. Drews, A., Prieske, H., Meyer, E. L., Senger, G. and Kraume, G. M., "Advantageous and detrimental effects of air sparging in membrane filtration: Bubble movement, exterted shear and particle classification," Desalination, 250, 1083- 1086(2010). https://doi.org/10.1016/j.desal.2009.09.113
  8. Yamanoi, I. and Kageyama, K., "Evaluation of bubble flow properties between flat sheet membranes in membrane bioreactor," J. Membr. Sci., 360, 102-108(2010). https://doi.org/10.1016/j.memsci.2010.05.006
  9. Liu, N., Zhang, Q., Chin, G. L., Ong, E. H., Lou, J., Kang, C. W., Liu, W. and Jordan, E., "Experimental investigation of hydrodynamic behavior in a real membrane bio-reactor unit," J. Membr. Sci., 353, 122-134(2010). https://doi.org/10.1016/j.memsci.2010.02.042
  10. Zhang, K., Cui, Z. and Robert, W. F., "Effect of bubble size and frequency on mass transfer in flat sheet MBR," J. Membr. Sci., 332, 30-37(2009). https://doi.org/10.1016/j.memsci.2009.01.033
  11. Rodrigues, R. T. and Rubio, J., "New basis for measuring the size distribution of bubbles," Minerals Eng., 16(8), 757-765(2003). https://doi.org/10.1016/S0892-6875(03)00181-X
  12. French, K., Guest, R. K., Finch, G. R. and Haas, C. N., "Correlating cryptosporidium removal using dissolved air flotation in water treatment," Water Res., 34(16), 4116-4119(2000). https://doi.org/10.1016/S0043-1354(00)00164-0
  13. Dupre, V., Ponasse, M., Aurelle, Y. and Secq, A., "Bubble formation by water release in nozzles-I. Mechanisms," Water Res., 32(8), 2491-2497(1998). https://doi.org/10.1016/S0043-1354(97)00435-1
  14. Ponasse, M, V. Dupre, V, Aurelle, Y, and Secq, A, "Bubble formation by water release in nozzles-II. Influence of various parameters on bubble size," Water Res., 32(8), 2498-2506 (1998). https://doi.org/10.1016/S0043-1354(97)00436-3