Abstract
This study measured a vibration level at each distance of construction fields where blasts occur using Lion measuring instrument and used BlastmateIII to measure vibration velocity at the same distance. A total 130 blasts occurred with the weight of a total of 5,180 kg and the number of blast holes per blast was 5, 10 and 20. The weight of 4 kg was used for each hole. Vibrations caused by blast was measured at the distance with the same velocity and level. Measurements were carried 15~102 m away from the blast source. and 273 data on vibration velocity and level were obtained from eight measurements. It analysed data on vibration velocity measured based on existing correlation formulas and compared them to real measurements to analyse interrelationship.
본 연구에서는 발파가 이루어지는 공사현장에서의 거리별 진동레벨을 리온계측기로 측정하였고 같은 거리상에서 진동속도를 측정을 위해 BlastmateIII를 사용하였다. 현장실험에서 발파는 총 5,180kg의 장약량으로 총 130회의 발파가 진행되었으며 회당 발파공수는 5, 10, 20공으로 공당 4kg의 약량이 사용되었다. 발파로 인한 진동은 진동속도와 진동레벨로 같은 거리에서 동시 측정하였다. 계측은 발생원으로부터 15~102m 구간에서 측정하였고 8차례 구간을 나누어 진동속도, 진동레벨 데이터를 각각 273개 획득하였다. 측정된 진동속도 데이터를 이용하여 기존의 상관식에 의하여 분석하였으며 이를 실제 측정한 진동레벨과 비교 분석하고 상관성에 대하여 연구해 보았다.