Treatment of Metacarpal Bone Fracture Using Biodegradable Plates and Screws

흡수성 고정판과 나사를 이용한 중수골 골절의 치료

  • Cho, Jeong-Mok (Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine) ;
  • Eun, Seok-Chan (Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine) ;
  • Baek, Rong-Min (Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine)
  • 조정목 (서울대학교 의과대학 성형외과학교실) ;
  • 은석찬 (서울대학교 의과대학 성형외과학교실) ;
  • 백롱민 (서울대학교 의과대학 성형외과학교실)
  • Received : 2011.04.21
  • Accepted : 2011.06.03
  • Published : 2011.07.10

Abstract

Purpose: Metacarpal fractures are common hand injury that may require operative intervention to ensure adequate reduction and stabilization. Traditionally, titanium miniplate was used for rigid fixation of bone fractures. However, the use of permanent plate lends itself to multiple complications such as infection, exposure of the hardware, tendon adhesions, tendon rupture, prolonged pain, bony atrophy and osteoporosis (stress shielding), metal sensitization, and palpation under the skin. This study evaluated the usefulness and stability of biodegradable plates and screws for treatment of metacarpal bone fractures. Methods: There was 17 patients who had surgery for metacarpal bone fracture from April 2007 to June 2010. All patients had open reduction and internal fixation. We used absorbable plates and screws (Inion CPS$^{(R)}$) for internal fixation. Postoperative results were assessed with x-ray. Stability of plates and screws, healing process and its complications were observed by clinical and radiographic assessment. Results: All patients were successfully reduced of bone fracture, and fixations with absorbable plates and screws were stable. The mean follow up period was 7.1 months. 2 patients complained postoperative pain, but they were relieved with analgesics. All patients experienced transient stiffness, but they were relieved with active assistive range of motion after removal of splint. No patients suffered complications which could be occurred by using metallic plate. Conclusion: There was no critical complications such as re-fracture or nonunion among patients. No patients suffered side effects related with metallic implants. Biodegradable implants can offer clinically stable and attractive alternative to metallic implants to stabilize metacarpal bone fractures in the hand.

Keywords

References

  1. Stern PJ, Wieser MJ, Reilly DG: Complications of plate fixation in the hand skeleton. Clin Orthop Relat Res 214 : 59, 1987
  2. Lionelli GT, Korentager RA: Biomechanical failure of metacarpal fracture resorbable plate fixation. Ann Plast Surg 49: 202, 2002 https://doi.org/10.1097/00000637-200208000-00015
  3. Waris E, Ashammakhi N, Kaarela O, Raatikainen T, Vasenius J: Use of bioabsorbable osteofixation devices in the hand. J Hand Surg Br 29: 590, 2004 https://doi.org/10.1016/j.jhsb.2004.02.005
  4. Bozic KJ, Perez LE, Wilson DR, Fitzgibbons PG, Jupiter JB: Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation. J Hand Surg Am 26: 755, 2001 https://doi.org/10.1053/jhsu.2001.24145
  5. Waris E, Ninkovic M, Harpf C, Ninkovic M, Ashammakhi N: Self-reinforced bioabsorbable miniplates for skeletal fixation in complex hand injury: three case reports. J Hand Surg Am 29: 452, 2004 https://doi.org/10.1016/j.jhsa.2004.01.013
  6. Dumont C, Fuchs M, Burchhardt H, Appelt D, Bohr S, Sturmer KM: Clinical results of absorbable plates for displaced metacarpal fractures. J Hand Surg Am 32: 491, 2007 https://doi.org/10.1016/j.jhsa.2007.02.005
  7. Hughes TB: Bioabsorbable implants in the treatment of hand fractures: an update. Clin Orthop Relat Res 445: 169, 2006
  8. Fan Y, Xiu K, Duan H, Zhang M: Biomechanical and histological evaluation of the application of biodegradable poly-L-lactic cushion to the plate internal fixation for bone fracture healing. Clin Biomech (Bristol, Avon) 23: S7, 2008 https://doi.org/10.1016/j.clinbiomech.2008.01.005
  9. Bostman OM, Pihlajamaki HK: Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Relat Res 371: 216, 2000 https://doi.org/10.1097/00003086-200002000-00026
  10. Yerit KC, Hainich S, Turhani D, Klug C, Wittwer G, Ockher M, Ploder O, Undt G, Baumann A, Ewers R: Stability of biodegradable implants in treatment of mandibular fractures. Plast Reconstr Surg 115: 1863, 2005 https://doi.org/10.1097/01.PRS.0000165075.51898.6F
  11. Klos K, Rausch S, Loffler M, Frober R, Hofmeier K, Lenz M, Hofmann GO, Muckley T: A biomechanical comparison of a biodegradable volar locked plate with two titanium volar locked plates in a distal radius fracture model. J Trauma 68: 984, 2010
  12. Givissis PK, Stavridis SI, Papagelopoulos PJ, Antonarakos PD, Christodoulou AG: Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment. Clin Orthop Relat Res 468: 3377, 2010 https://doi.org/10.1007/s11999-010-1388-3
  13. Waris E, Ashammakhi N, Raatikainen T, Tormala P, Santavirta S, Konttinen YT: Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study. J Hand Surg Am 27: 902, 2002 https://doi.org/10.1053/jhsu.2002.35082
  14. Waris E, Ashammakhi N, Happonen H, Raatikainen T, Kaarela O, Tormala P, Santavirta S, Konttinen YT: Bioabsorbable miniplating versus metallic fixation for metacarpal fractures. Clin Orthop Relat Res 410: 310, 2003 https://doi.org/10.1097/01.blo.0000063789.32430.c6