DOI QR코드

DOI QR Code

Experimental Study on the Performance of a CO2 Heat Pump Water Heater under Various Operating Conditions

이산화탄소 급탕 열펌프의 운전조건에 따른 성능 특성에 관한 실험적 연구

  • Sohn, Dong-Jin (Graduate School of Mechanical Engineering, Korea University) ;
  • Baek, Chang-Hyun (Graduate School of Mechanical Engineering, Korea University) ;
  • Heo, Jae-Hyeok (Department of Mechanical Engineering, Korea University) ;
  • Kang, Hoon (Department of Mechanical Engineering, Korea University) ;
  • Kim, Yong-Chan (Department of Mechanical Engineering, Korea University)
  • 손동진 (고려대학교 기계공학과 대학원) ;
  • 백창현 (고려대학교 기계공학과 대학원) ;
  • 허재혁 (고려대학교 기계공학과) ;
  • 강훈 (고려대학교 기계공학과) ;
  • 김용찬 (고려대학교 기계공학과)
  • Received : 2010.12.08
  • Accepted : 2011.02.23
  • Published : 2011.04.10

Abstract

In this study, the steady state performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, compressor frequency, EEV opening, and water mass flow rate. Transient state performance tests were also conducted to investigate major system effects associated with the interaction between the $CO_2$ heat pump water heater and the water tank. Optimum refrigerant charge amount for the system was 1600 g. At compressor frequencies of 50 Hz and 60 Hz, water mass flow rates of 95 kg/h and 105 kg/h, and EEV opening of 8% and 16%, the water heating temperatures were $65^{\circ}C$ and $68^{\circ}C$ and COPs were 3.0 and 2.8, respectively. In the transient condition, the instantaneous COP decreased with an increase in the inlet water temperature.

Keywords

References

  1. Hwang, Y. and Radermacher, R., 1999, Experimental investigation of the $CO_{2}$ refrigeration cycle, ASHRAE Transactions, Vol. 105, No.1, pp. 1219-1227.
  2. Hwang, Y. and Radermacher, R., 2002, Options for a two.-stage carbon dioxide cycle, 5th IIT-Gustav Lorentzen Natural Working Fluids Conference at Guangzhou, pp. 143-149.
  3. Chen, Y. and Gu, J., 2005, The Optimum High Pressure for $CO_{2}$ Transcritical Refrigeration Systems with Internal Heat Exchangers, Int. Journal of Refrigeration, Vol. 28, No.9, pp. 1238-1249.
  4. Hermann, H. and Rene, R., 2000, $CO_{2}$ as refrigerant possible applications, 4th IIR-Gustav Lorentzen Conference, pp. 43-50.
  5. Fernandez, N., Hwang, Y. and Redennacher, R., 2010, Comparison of $CO_{2}$ heat pump water heater performance with baseline cycle and two high COP cycles, Int. Journal of Refrigeration, Vol. 33, No.3, pp. 635-644. https://doi.org/10.1016/j.ijrefrig.2009.12.008
  6. Kobayahsi, M., 2008, $CO_{2}$ heat pump heating and water heater system for cold area, 9th Int. lEA Heat Pump Conference.
  7. Murahashi, E., 2008, Development of multi function $CO_{2}$ heat pump water heater, 9th Int. lEA Heat Pump Conference.
  8. Cho, H., Ryu, C. and Kim, Y., 2007, Cooling perfonnance of a variable speed $CO_{2}$ cycle with an electronic expansion valve and internal heat exchanger, Int. Journal of Refrigeration, Vol. 30, No.4, pp. 664-671. https://doi.org/10.1016/j.ijrefrig.2006.10.004
  9. Cho, H., Baek, C., Park, C., and Kim, Y., 2009, Perfonnance evaluation of a two-stage $CO_{2}$ cycle with gas injection in the cooling mode operation, Int. Journal of Refrigeration, Vol. 32, No.1, pp. 40-46. https://doi.org/10.1016/j.ijrefrig.2008.07.008
  10. ASHRAE, 1983, Methods of testing for seasonal efficiency of unitary air-conditioner and heat pumps, ASHRAE Standard 116.